3. Operations 

3-1. Button Operation 
 

 

 

Button 

Function   

ON/MUTE Button   

 

Turn on the UPS: Press and hold ON/Mute button for at least 2 
seconds to turn on the UPS. 

 

Mute the alarm: After the UPS is turned on in battery mode, press 
and hold this button for at least 5 seconds to disable or enable the 
alarm system. But it

s not applied to the situations when warnings or 

errors occur.   

 

Up key:

 Press this button to display previous selection in UPS setting 

mode. 

 

Switch to UPS self-test mode: 

Press and hold ON/Mute button 

for 5 

seconds to enter UPS self-testing while in AC mode 

OFF/ENTER 

Button   

 

Turn off the UPS: Press and hold this button at least 2 seconds to turn 

off the UPS     

 

Confirm selection key: Press this button to confirm selection in UPS 
setting mode.   

SELECT Button   

 

Switch LCD message: Press this button to change the LCD message 

for input voltage, input frequency, battery voltage, output voltage 
and output frequency.   

 

Setting mode: Press and hold this button for 5 seconds to enter UPS 
setting mode when UPS is off.   

 

Down key:

 Press this button to display next selection in UPS setting 

mode. 

 
3-2. LCD Panel 

 
Rack Display       

 

 

 

 

 

 

 

 

Tower Display 

 
 

 
 
 
 
 
 
 
 
 
 

Battery info 

Load info 

Input/output   

and Battery 

  info 

UPS status 

Warning   

& Fault info/ 
Setting 

operation 

Backup   

time 
info 

Load info 

UPS status 

Backup time 
info 

Input/output   

and Battery 
info 

Warning & Fault info/   
Setting operation 

Battery info 

Содержание EA300PRO series

Страница 1: ...Line Interactive Sinewave UPS 800 1 1K 1 5K 2K 2 5K 3K VA Uninterruptible Power Supply System User Manual...

Страница 2: ...l View 4 2 2 Install The UPS 5 2 3 Setup The UPS 5 2 4 Battery Replacement 7 2 5 Battery Kit Assembly Option 8 3 Operations 10 3 1 Button Operation 10 3 2 LCD Panel 10 3 3 Audible Alarm 11 3 4 LCD Dis...

Страница 3: ...er them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed sh...

Страница 4: ...must be kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the...

Страница 5: ...a Type 2 5K 3K India Type 800 1 1K 1 5K NEMA Type 2K NEMA Type 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit br...

Страница 6: ...nstallation Step 1 Step 2 Tower Installation Step 1 Step 2 Step 3 2 3 Setup The UPS Step 1 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension c...

Страница 7: ...00 card in the UPS it will provide advanced communication and monitoring options PS USB port and RS 232 port can t work at the same time Step 4 Network connection Network Fax Phone surge port Connect...

Страница 8: ...monitoring software will appear as an orange plug icon located in the system tray near the clock 2 4 Battery Replacement NOTICE This UPS is equipped with internal batteries and user can replace the b...

Страница 9: ...3 Put assembled battery packs on one side of plastic shells and insert one more defect battery on the space Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly we...

Страница 10: ...tapes Step 2 Connect all battery terminals by following below chart Step 3 Put assembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as below chart Then ba...

Страница 11: ...on Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS Confirm selection key Press this button to confirm selection in UPS setting mode SELECT Button Switch LCD message...

Страница 12: ...ion Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuited UPS status Indicates that programmable management outlets are wor...

Страница 13: ...ts setting LCD display direction and exit 01 Output voltage setting Interface Setting For 208 220 230 240 VAC models you may choose the following output voltage 208 presents output voltage is 208Vac 2...

Страница 14: ...ing programmable outlet Step 1 Before entering setting mode the UPS should be in Stand by mode off charging and make sure the battery is connected The LCD display is shown as right Step 2 Press and ho...

Страница 15: ...LCD display ECO mode When the input voltage is within voltage regulated range UPS will power the output directly from the mains ECO is an abbreviation of Efficiency Corrective Optimizer In this mode w...

Страница 16: ...28 Inverter soft start fail 11 x Over temperature 41 x Inverter voltage high 12 x Over load 43 Inverter voltage Low 13 x 3 8 Warning Indicator Warning Icon flashing Alarm Low Battery Sounding every se...

Страница 17: ...The external or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 and the icon is lighting on LCD display and alarm is continuously soundin...

Страница 18: ...ckup time is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries de...

Страница 19: ...ealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperat...

Страница 20: ...to 90 capacity Long run Model Charging Current N A 4 A 8A N A 4 A 8A N A 4 A 8A Charging Voltage 27 4 VDC 1 54 8 VDC 1 82 1 VDC 1 PROTECTION Full Protection Overload short discharge and overcharge pro...

Отзывы: