Click the following operation to enter the unit function of setting pivot variables:
(4 detailed Settings) → (2 signal conditions) → (1 user range unit)

7.2 set the upper limit of the range

The upper limit of the range can be set by following:
(4 detailed Settings) → (2 signal conditions) → (2 user range upper limit)

7.3 set the lower limit of the range

The lower limit function of the set range can be entered by following operations:
(4 detailed Settings) → (2 signal conditions) → (3 lower limit of user range)

7.4 setting damping

Press the following operation to enter the setting damping function:
(4 detailed Settings) → (2 signal conditions) → (4 damping)

7.5 output current fine-tuning

Press the following operation to enter the output current fine-tuning function:
(2 diagnosis and maintenance) → (3 calibration) → (1 output fine-tuning)
Note: the output current fine-tuning function can only be performed when HART
instrument leaves the factory and is tested periodically.The use of this function
requires the authorization of the HART instrument owner, otherwise the output error
of HART instrument may be increased.

7.6 pivot variable zeroing

Click the following operation to enter the pivot variable zeroing function :(some
instruments do not have this function)
(2 diagnosis and maintenance) → (3 calibration) → (3 sensor fine-tuning) → (1
zero calibration)

Note:

the zero setting function of the principal variable can correct the zero

deviation of the instrument output caused by the installation position, which can
only be carried out when the HART instrument is first installed and the instrument
cycle is verified.The use of this function requires the authorization of the HART
instrument owner, otherwise the output error of HART instrument may be
increased.

Содержание HART 475

Страница 1: ...1 HART 475 COMMUNICATOR USER MANUAL Hangzhou Zhongchuang Electron Co Ltd...

Страница 2: ...vironment 4 Keyboard Introduction 4 Establish Connection 4 Funtion Introduction 6 Common Function Operation Example 9 Polling Meter Battery Power 12 Instrument Information 12 Language Selection 12 Res...

Страница 3: ...ilt in 1 3 Dedicated test line 1 4 Charger 1 5 250 ohm resistor 2 6 User manual 1 Production Introduction HART series manual operators are suitable for the communication operation of HART protocol int...

Страница 4: ...g temperature range 0 C 50 C Storage temperature range 20 C 55 C Note Exploding the device in the sun will significantly shorten the life of the LCD panel and accelerate the aging of the button panel...

Страница 5: ...nected or disconnected Set as connectting internal resistance there is no need to connect external resistance When set to disconnect the internal resistance the external resistance should be connected...

Страница 6: ...d well After the meter loop is connected correctly hold down the power button for three seconds and the LCD screen is lit to indicate that the device has been working Hold down the power button for th...

Страница 7: ...e 3 battery power 4 local information 5 language 6 resistance connection For any type of meter you can always return to the item menu by pressing the left arrow key or the Back key several times Ifent...

Страница 8: ...inspection it can achieve equipment self inspection and report the test results Selecting circuit current detection the transmitter can output a fixed current signal to verify whether the whole circu...

Страница 9: ...main menu to enter the detailed Settings menu which provides more configuration information For different HART devices the detailed Settings are quite different Only through the registered device its...

Страница 10: ...ntenance 3 calibration 1 output fine tuning Note the output current fine tuning function can only be performed when HART instrument leaves the factory and is tested periodically The use of this functi...

Страница 11: ...unicator will automatically poll all connected devices from address 0 to address 15 The second item in the menu is single point polling You can choose any address between 0 and 15 for communication If...

Страница 12: ...wer Select the third item from the item menu to enter the display battery power function which will detect the remaining battery power in the current communicator When the battery power is too low ple...

Страница 13: ...ns 13 1 the communicator is not connected to the meter 1 check whether the loop equipment supports HART function 2 check the size of the circuit load resistance load resistance should be between 250 5...

Страница 14: ...pull the data line to avoid the bad contact of the line and the unusable situation 14 4 please press the keyboard lightly to avoid heavy hitting and extend the life of the keyboard 14 5 batteries sho...

Отзывы: