background image

 

                                               

1

                                     

 

1.

 

Installation 

This chapter describes some checks that must be made when you receive the instrument  and 

the conditions that you must learn and be equipped with before installing the instrument. 

 

1.1

 

Out of Box Check 

Thank you for purchasing and using our products. Before using this instrument, please 

confirm the contents of the last chapter "Warranty". In case of any non-conformity, please contact 

us as soon as possible to safeguard your interests. Make sure that the following items are attached 

to the bridge, where the optional accessories are included with the product only when ordered. If 

any items are missing, please contact your nearest sales office. 

Standard Accessories: 

●Four

-terminal-pair Kelvin test cable (35A51). 

● Three

-core power cord (30A51). 

● One User Manual.

 

Optional accessories: 

●RS232 serial cable / USB data cable.

 

●Handle cable.

 

●Four

-terminal-pair Kelvin test fixture (including 

short block) 

●SMD component test fixture (including short 

block) 

1.2

 

  Power connection 

(1) Power supply voltage range: 220V AC ± 10%, or 110V AC ± 10%. 

(2) Power supply frequency range: 45-65Hz. 

(3) Phase line L, zero line N, and ground line E of power input shall be the same as those of the 

power plug of this instrument. 

(4) The instrument has been carefully designed to reduce the clutter interference caused by the 

input at the AC power supply terminal. However, it shall be used in a low noise environment. If 

such is not the case, please install the power supply filter. 

WARNING: In order to prevent leakage from causing damage to the instrument or person, the user 

must ensure that the ground line of the power supply is reliably connected to the earth. 

 

1.3

 

Fuses 

The instrument has been provided with fuses in delivery; the user shall use the fuses provided by 

the company. 

 

1.4

 

Ambient Environment 

(1) Please do not use it in the place subject to dust, vibration, direct sunlight and corrosive 

gas. 

(2)  The  normal  working  temperature  of  this  instrument  is  0  ℃  ~  40  ℃,  and  working 

humidity is from 15% to 85%; Therefore please use the instrument in this condition as far as 

possible to ensure the measurement accuracy. 

(3) The instrument has been carefully  designed to reduce the clutter interference caused by 

the input at the AC power supply terminal. If such is not the case, please install the power supply 

filter.   

(4) If the instrument is not to be used for a long time, please put it in the original box or 

similar  box  and  store  it  in  the  ventilated  room  with  temperature  of  0  ℃  ~  40  ℃  and  relative 

humidity of not more than 85% RH; The air in the room shall not contain harmful impurities 

Содержание ET44 Series

Страница 1: ...ET44 Series Benchtop digital bridge ET4401 LCR METER...

Страница 2: ...7 Main Parameter Selection 10 4 2 8 Secondary Parameter Selection 10 4 2 9 Equivalent Mode Selection 10 4 2 10 Comparator Setting 10 4 2 11 List Scanning Function 12 4 2 12 DCR MODE 13 4 2 13 Electro...

Страница 3: ......

Страница 4: ...ug of this instrument 4 The instrument has been carefully designed to reduce the clutter interference caused by the input at the AC power supply terminal However it shall be used in a low noise enviro...

Страница 5: ...e instrument the warm up time shall be no less than 30 minutes after the instrument is turned on the continuous working hours shall be less than 16 hours 2 Please do not switch the instrument frequent...

Страница 6: ...ge R 0 0001 99 99M Basic Accuracy 0 2 Test Frequency Hz 100 10kHz 10 point 100 20kHz 12point 100 100kHz 20 point Measurement Display Speed 2 times second slow 4 times second medium speed 8 times sec f...

Страница 7: ...ower consumption 10W 3 Quick Reference 3 1 Front Panel 1 2 3 4 ET4401 LCR METER Figure 3 1 Diagram of Front Panel SN Description 1 Power button 2 3 5 inch display 3 Test clip jack 4 Basic Function Key...

Страница 8: ...n again to enter the calibration state after the calibration is completed press down again to exit the calibration mode and return to the normal mode ENTER Press down to make the measurement condition...

Страница 9: ...4 User Interface 3 4 1 Interface of Measurement Display Cp D 0mV Cp 1 4728pF D 0 0281 600mV 1kHz Cp D Cp 1 4728pF D 0 0281 MAX Cp D 0mV 600mV 1kHz Cp D MEAS DISP 1 4728 0 0281 LOCAL AUTO Cp D 0mV 600m...

Страница 10: ...ow High 1 2 3 2nd 05 00 OFF 001 4pF Fig 3 4 Interface of Measurement Display 3 4 3 Interface of List Scanning List Scan MAX 2 1 3 4 5 6 7 Mode Freq Nom 001 5pF Seq Disp OFF Num Low High Value Comp Fig...

Страница 11: ...0281 600mV 1kHz Cp D Cp 1 4728pF D 0 0281 MAX Cp D 0mV 600mV 1kHz Cp D 1 4728 0 0281 Cp D 600mV Cp pF D 100 0mV 1kHz Cp D Cp D 0mV Cp 1 4728pF D 0 0281 600mV 1kHz Cp D Cp 1 4728pF D 0 0281 MAX Cp D 0m...

Страница 12: ...e Turn on the instrument to enter the interface of measurement display move the cursor to the measurement range area and switch the range through the up and down direction keys AUTO 30 100 300 1k 3k 1...

Страница 13: ...ponent with the similar desired nominal value Step two Press the COMPARE key to open the Interface of Measurement Setting At this time the position of the cursor is at the nominal value in default The...

Страница 14: ...00 OFF 001 4pF MEAS SET Nom Comp MAX Local Low High 1 2 3 2nd 05 00 OFF 001 4pF Fig 4 5 Fig 4 6 Method Two Step one the same as method one Step two move the cursor to the tolerance through the left a...

Страница 15: ...ion keys and enter Interface of List Scanning by means of switching the up and down switch Keys as shown in Fig 4 9 and 4 10 The List Scanning Function can carry out circulated scanning over seven gro...

Страница 16: ...Function Short press the NULL key to open and take the current value as the reference value secondary parameter will display the reference value and Main parameter will display the relative value the...

Страница 17: ...r example Press MAX key the first time to display the maximum value press the second to exit the record maximum mode The interface is as shown in Fig 4 16 Cp D 0mV Cp 1 4728pF D 0 0281 600mV 1kHz Cp D...

Страница 18: ...HORT with the interface as shown in Fig 4 18 the number will be added 1 along with the correction progress If the correction is successful the word success is displayed in the position where Digital i...

Страница 19: ...dicators 5 1 Measurement Parameter 1 Main parameter L inductance C capacitance R resistance Z impedance 2 Secondary parameter X reactance D loss Q quality factor impedance angle ESR series equivalent...

Страница 20: ...e series connection equivalent and p represents the parallel connection equivalent In general the series equivalent circuit shall be used for low value impedance elements basically high value capacita...

Страница 21: ...tor The maximum and minimum values of the measurement parameters that affect accuracy Frequenc y Hz 100 120 200 400 800 1K 2K 4K 8K 10K Cmax 800 667 400 200 100 80 40 20 10 8 Cmin 1500 1250 750 375 18...

Страница 22: ...4 0 4 2 2 5 4 DCR MEASUREMENT ACCURACY Range Display Range Accuracy Re 100M 20 00M 99 99M 10 0 20 words 20M 10 00M 20 00M 5 0 10 words 10M 4 000M 9 999M 2 0 5 words 4M 400 0k 3 9999M 1 2 3 words 400k...

Страница 23: ...on protocol refers to SCPI part 6 2 RS232 INTERFACE The RS232 connector uses 9 pin DB socket with the pin sequence as shown below Pin definition 2 pins RXD receive data 3 pins TXD send data 5 pins GND...

Страница 24: ...be maintained and repaired by professional technical personnel please do not arbitrarily replace various components within the instrument in maintenance after the maintenance a new measurement and cal...

Отзывы: