manualshive.com logo in svg
background image

ET1300/1301/1302/1303 Programmable

DC Electronic Load User Manual

Hangzhou Zhongchuang Electronics Co., Ltd.

Содержание ET1300

Страница 1: ...ET1300 1301 1302 1303 Programmable DC Electronic Load User Manual Hangzhou Zhongchuang Electronics Co Ltd...

Страница 2: ...Hangzhou Zhongchuang Electronics Co Ltd Adress NO 3 Kangle Road Gongshu District Hangzhou China Postcode 310015 Telephone 0086 571 56861333 Fax 0086 571 56861355 Website http www east tester com...

Страница 3: ...ower output within a certain range Support 4 wire measurement The list test mode can simulate a variety of loading status changes The short circuit test can be used to simulate load short circuit Supp...

Страница 4: ...tant power mode 6 2 4 5 Constant current to constant voltage mode 6 2 4 6 Constant resistance to constant voltage mode 6 2 5 Tran Test 7 2 6 List Test 8 2 7 Scan Test 11 2 8 Battery Test 12 2 9 LED Te...

Страница 5: ...art Guide 1 1 Front panel LCD display Icon bar there are five types of icons on the electronic load interface 1 2 Front panel key It indicates keyboard lockout It indicates remote control It indicates...

Страница 6: ...s cannot be used Local For switching to the local mode Trigger Trigger key for manual trigger Keys used for moving the cursor left or right Range I Shortcut key for current range switching Range V Sho...

Страница 7: ...n remote operation mode the corresponding icon will be displayed on the top of the interface At this time the interface is locked and the status and operation of the instrument can be controlled throu...

Страница 8: ...nt voltage mode CV constant resistance mode CR constant power mode CP constant current to constant voltage mode CC CV constant resistance to constant voltage mode CC CR The parameter settings for the...

Страница 9: ...ettings please refer to 1 4 Numeric Parameter Setting for details 3 Press the corresponding On Off to turn on the load Figure 2 4 2 Constant voltage mode 2 4 3 Constant resistance mode In constant res...

Страница 10: ...rce to be measured from being damaged by overcurrent discharge In this mode when the source to be measured cannot output the current value set by the load it will automatically switch from constant cu...

Страница 11: ...be used to test the dynamic characteristics of the power source Moreover the Tran test is divided into three modes continuous mode pulse mode and trigger mode as described below Continuous mode in th...

Страница 12: ...mated testing of production line Preset the steps of the list test and then edit the test steps and test parameters of the source to be measured into a list and complete a series of tests in sequence...

Страница 13: ...tch to the edit state before any parameter can be edited Press the direction key to select the previous or next page and then press Enter to turn the page Press the direction key to select save and th...

Страница 14: ...he edit state before any file can be edited Press the direction key to select the previous or next page and then press Enter to turn the page 3 Turn the knob to select store recall or delete the file...

Страница 15: ...orking conditions of the source to be measured within a certain range and makes it easy to capture various critical parameters of the source to be measured such as protection current break over voltag...

Страница 16: ...to measure the discharge capacity of the battery Operating instructions 1 Press Menu in the main interface of battery test to enter the battery parameters setting interface 2 Select the action item b...

Страница 17: ...structions 1 Select the action item by rotating the knob 2 For parameter setting please refer to 1 4 Numeric Parameters Setting for details 3 Press On Off to turn on or off the mode Option Description...

Страница 18: ...voltage overpower over temperature protection and reverse polarity prompt the prompt information is subject to the real picture 2 13 Trigger function The load has trigger function which is mainly used...

Страница 19: ...ction The load also added the lock function to prevent user misoperations The title bar will display the lock identifier In the lock out state all the other keys including the knob are locked except O...

Страница 20: ...ffectiveness F1 The list test result is unqualified low effectiveness G GND Expansion port input N1 External trigger input The extension port output is OC gate output The user needs to connect the pul...

Страница 21: ...ange 0 400W Resolution 10mW Accuracy 0 1 0 5 FS Tran Test Mode CC CV T1 T2 50ms 60s Battery Test Accuracy CC CR Discharge mode 9999Ah Maximum discharge capacity 1mA 10mA 10m 100m Range of measurement...

Страница 22: ...Resolution 10mW Accuracy 0 1 0 5 FS Tran Test Mode CC CV T1 T2 50ms 60s Battery Test Accuracy CC CR Discharge mode 9999Ah Maximum discharge capacity 1mA 10mA 10m 100m Range of measurement Voltage read...

Отзывы: