EAST PENN Deka unigy I Battery 1 Скачать руководство пользователя страница 10

®

10 

APPENDIX D

BATTERY MAINTENANCE REPORT

Charger Output  _____________________ Amp 

Air Temperature ______________________°F

Total Battery String Voltage ________________ 

Panel Meter Volts ______________________

  Unit 

 

Ohms or  Unit 

 

Ohms or  Unit 

 

Ohms or  Unit 

 

Ohms or  Unit 

 

Ohms or  Unit 

 

Ohms or 

 No. Volts  Mhos  No. Volts  Mhos  No. Volts  Mhos  No. Volts Mhos  No. Volts  Mhos  No.  Volts  Mhos

Inspection Date _____________________________________________________________________ 

No. of Units/String __________________

Company ___________________________________________________________________________ Type _______________________________

Address ____________________________________________________________________________ 

Date New __________________________

Battery location and/or number ______________________________________________________ 

Date Installed _______________________

Readings Taken By ____________________________  Remarks/Recommendations __________________________________________________________

Readings should be taken at installation and annually thereafter.                

 _________________________________________________________________________________

 1 

41 

81 

121 

161 

201

 2 

42 

82 

122 

162 

202

 3 

43 

83 

123 

163 

203

 4 

44 

84 

124 

164 

204

 5 

45 

85 

125 

165 

205

 6 

46 

86 

126 

166 

206

 7 

47 

87 

127 

167 

207

 8 

48 

88 

128 

168 

208

 9 

49 

89 

129 

169 

209

 10 

50 

90 

130 

170 

210

 11 

51 

91 

131 

171 

211

 12 

52 

92 

132 

172 

212

 13 

53 

93 

133 

173 

213

 14 

54 

94 

134 

174 

214

 15 

55 

95 

135 

175 

215

 16 

56 

96 

136 

176 

216

 17 

57 

97 

137 

177 

217

 18 

58 

98 

138 

178 

218

 19 

59 

99 

139 

179 

219

 20 

60 

100 

140 

180 

220

 21 

61 

101 

141 

181 

221

 22 

62 

102 

142 

182 

222

 23 

63 

103 

142 

183 

223

 24 

64 

104 

144 

184 

224

 25 

65 

105 

145 

185 

225

 26 

66 

106 

146 

186 

226

 27 

67 

107 

147 

187 

227

 28 

68 

108 

148 

188 

228

 29 

69 

109 

149 

189 

229

 30 

70 

110 

150 

190 

230

 31 

71 

111 

151 

191 

231

 32 

72 

112 

152 

192 

232

 33 

73 

113 

153 

193 

233

 34 

74 

114 

154 

194 

234

 35 

75 

115 

155 

195 

235

 36 

76 

116 

156 

196 

236

 37 

77 

117 

157 

197 

237

 38 

78 

118 

158 

198 

238

 39 

79 

119 

159 

199 

239

 40 

80 

120 

160 

200 

240

  Avg. Voltage 

Avg. Voltage 

Avg. Voltage 

Avg. Voltage 

Avg. Voltage 

Avg. Voltage

Individual  

Battery Readings

Содержание Deka unigy I Battery 1

Страница 1: ...tring is defined as a series connected electrical system comprised of batteries individual 12 volt units Protective Equipment Although VRLA batteries can vent or leak small amounts of electrolyte elec...

Страница 2: ...d at the time of actual unloading each package should be visually inspected for any possible damage or electrolyte leakage If either the entire shipment should be conducted and noted on the bill of la...

Страница 3: ...ompleted for each refresh charge 8 Batteries shall not be stored beyond 12 months Storing beyond 12 months will affect warranty 9 If the storage refresh requirements cannot be met contact the East Pen...

Страница 4: ...East Penn Mfg Safe installation of any venting equipment is the responsibility of the installer BATTERY ASSEMBLY ALWAYS WEAR EYE PROTECTION 1 Set up the battery string so that the positive post of one...

Страница 5: ...rify that the installer did torque all connections properly to 100 in lb 5 Micro ohm readings should be taken across every connection Refer to meter manufacturer s instructions for proper placement of...

Страница 6: ...an 20 from initial readings taken retorque the connection Retourque value is equal to initial torque value as indicated in BATTERY ASSEMBLY section Recheck the micro ohm reading If the reading remains...

Страница 7: ...tery 2 Battery 3 Battery 4 Battery 5 Battery 6 Battery 7 Battery 8 Battery 9 Battery 10 Battery 11 Battery 12 Battery 13 Battery 14 Battery 15 Battery 16 Battery 17 Battery 18 Battery 19 Battery 20 Ba...

Страница 8: ...84 2 28 13 46 14 36 82 4 27 13 48 14 38 80 6 26 13 49 14 39 78 8 25 13 50 14 40 77 0 24 13 51 14 41 75 2 23 13 52 14 42 73 4 22 13 54 14 44 71 6 21 13 55 14 45 69 8 20 13 56 14 46 68 0 19 13 57 14 47...

Страница 9: ...VR30 5 1 1 5 12AVR40 6 7 2 0 12AVR75 13 4 4 0 12AVR90 15 5 4 7 12AVR100 17 9 5 4 12AVR130 23 6 7 1 12AVR100ET 17 6 5 3 12AVR145ET 26 3 7 9 12AVR150ET 27 1 8 1 12AVR170ET 30 8 9 3 12AVR200ET 38 3 11 5...

Страница 10: ..._______________________________________________ Readings should be taken at installation and annually thereafter _________________________________________________________________________________ 1 41...

Страница 11: ...11 P a g e I n t e n t i o n a l l y B l a n k...

Страница 12: ...duced electronically or mechanically without written permission from the company E P M Form No 0902 02 22 2022 by EPM Printed in U S A East Penn Manufacturing Co Lyon Station PA 19536 0147 Phone 610 6...

Отзывы: