Siting the softener 



This should be as close to the rising main as possible. Allow hard water take off points for a drinking 
water facility and /or an outside tap 

if required. 

With modern softeners this is not essential, due to the 

quality of the resin. 



For easy DIY installation we recommend the fitting of a hard or filter water kit.  If the stopcock is located in 
a difficult position to create a hard water supply, you can fit a Reverse Osmosis system.  



The distance between the waste and the softener should be as short as possible.  



Ensure that both the waste and overflow are not subject to excessive temperatures 

(freezing or over 120°

F).  

 



If you are siting the softener in a cupboard, ensure that the base of the cupboard is adequately 
supported.  



If the softener is being installed in a loft, it is recommended that you place the softener within a well 
insulated 25-gallon tank. The overflow on the tank should be below the softener overflow and be a 
minimum of ¾” in size.  

Non Return Valve 

In single dwellings, a single check valve should be fitted. This is supplied with our 15mm installation kits and 
can be ordered separately.  

Check list  

If you purchased an EMWC fitting kit with your softener, all valves required for installation will be included. 
Combi boilers require a 

Combi Kit. 

Pressurised systems require a 

22mm Fitting Kit. 

Check you have ordered 

the correct fitting kit for your installation, before you start. 

Water Pressure Test 

It is important that you carry out a pressure test. High and low water pressure can result in damage to/failure of 
the softener. Although the softener is tested to a pressure of 8 bar we recommend the fitting of a pressure 
limiter should your pressure exceed 5 bar (70 psi). We also recommend that any household appliance using 

Planning your installation– the plumbing part. 

Always observe the water bylaws. Make sure there is only one rising main and that you are allowing space for access to 
the unit, for filling with salt and possible maintenance in the future. 



Check the water pressure - see below 



Locate the rising main (stop cock),  



You will need a waste facility  



The softener needs to be level  

SUMO Water Softener 

IMPORTANT INFORMATION 

Before starting the installation of the valves, ensure your STOP COCK IS IN A 

CLOSED position. 

NEED HELP? Check our installation video  

h ps://www.eastmidlandswater.com/Fi ngVideos

 

Page 4 

Содержание SUMO

Страница 1: ...Preparing to go into service 11 Resin Tank Valve Brine valve 6 Salt type and replenishment 12 Siting your softener 4 Setting up your softener 6 11 Starting up first time 11 Waste connection assembly 6...

Страница 2: ...environments It is not a water purifier It is recommended that you fit this softener to a municipal water supply Benefits include Energy savings Increased life of electrical appliances dishwashers was...

Страница 3: ...to dissolve ready for the next time the machine needs to regenerate The level of water in the tank will depend on the type size and water pressure feeding the softener Dependent on the amount of salt...

Страница 4: ...nstallation kits and can be ordered separately Check list If you purchased an EMWC fitting kit with your softener all valves required for installation will be included Combi boilers require a Combi Ki...

Страница 5: ...te 22mm t pieces and non return valves are not included in the fitting kit NEED HELP Check our installation video h ps www eastmidlandswater com Fi ngVideos SUMO Water Softener Drinking hard water div...

Страница 6: ...important as the brine line will be under pressure when your Sumo sof tener is in service Failure to check this element may result in leaks Step 3 Waste Connection Connect the 1 2 tube to the waste el...

Страница 7: ...y adjustments 1 Remove the small blue plastic locking clip on the adjustment knob It is simply removed by gently using your fingernail or a small screwdriver It is plastic so over zealous removal may...

Страница 8: ...Water Softener Hardness adjustment knob with blue clip Regeneration activator Viewer for programming Meter dial Close up of the hardness settings meter dial through the viewer This is set at 260 250 p...

Страница 9: ...e nut is on the inside of the cabinet With the elbow facing upwards ensure the nut on the inside is a snug finger tight tightness Step 4 Holding the nut with your fingers on the inside turn the elbow...

Страница 10: ...an be done by connecting to a 15mm copper tube for a maximum run of 8 meters with a minimum daytime pressure of 40psi Ensure that the waste hose is not kinked in any way as this could lead to an overf...

Страница 11: ...n See box below 6 When the water starts to flow continuously to waste fully open the water inlet valve to the system At this point you may notice that the waste water may have a slight yellowy brownis...

Страница 12: ...his product is available under many different names but it is basically a water softener resin cleaner For further advice please contact our sales department on 0116 276 3334 This product is available...

Отзывы: