9
EM
-
Ocean Water Softener
In service.
Water flows into the valve at the top, down through the resin and then up through the riser tube in the
middle of the vessel. As the water travels through the resin the ion exchange takes place. The
controllers are set to automatically regenerate on capacity.
The display on the control will show the following;
In service
and (
remaining capacity).
Routine Maintenance.
•
Check the salt level (this may need to be done more regularly depending on
consumption and the size of property/number of bathrooms).
•
The salt level should always be above the water level.
•
Check there is no sign of damage or leaks.
Programming the valve (in case of memory loss)
Should the programming have been lost in transit, the following instructions in conjunction with the
setting sheet will allow you to reset it. When the power has been connected, the valve will display the
valve model and initialise itself and then display
TIME
; you can then start to programme the valve.
Selections are made using the
UP
and
DOWN
buttons until the required setting is displayed; after each
setting, press
CONFIRM
to continue
Menu/confirm
Manual/
return
Down
Up
Display
screen