All the pictures in this manual are for explanation purpose only.
They may be slightly different from the heat pump you
purchased(depend on model).The actual shape shall prevail.
NOTE
Fix with bolt
6.4 Water Outlet
Four condensed water outlets on the chassis for selection
display as the follow figure:
Reserve water outlet
Reserve water outlet
Water Outlet
Outlet for power and connecting pipes
(Need to knock open)
(With rubber stopper)
10~16kW
2) Parallel connect the two units or above
3) Parallel connect the front with rear sides
>2000
>500
>3000
>3000
>300
>600
>2000
>300
6.3 Moving and installation
Since the gravity center of the unit is not at its physical center,
so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
1) Do not touch the fan with hands or other objects.
2) Do not lean it more than 45, and do not lay it sidelong.
3) Make concrete foundation accoding to the sepecif-ications of the
outdoor units.(refer to Fig.6-8)
4) Fasten the feet of this unit with bolts firmly to prevent it from
collapsing in case of earthquake or strong wind.Refer to Fig.6-8
CAUTION
While installing the outdoor unit, pay attention to the installation
place and the drainage pattern;
● For 4~8kW model units, there is only one water outlet on the
bottom pan. If it’s installed at low ambient temperature zone
(such as the ambient temperature is lower than -7 for a long
period), some heating devices should be install at the bottom pan
to prevent the drainage channel and water outlet from freezing,
or order a special unit for low temperature zone.
● For 10~16kW model units, if it’s installed at the low ambient
temperature zone, the frozen condensed water will block up the
water outlet, please pull out the rubber stopper of the reserve
water outlet. If that still fails to satisfy for the water draining,
please knock open the other two water outlets, and keep the
water can drain in time. Pay attention to the knock the reserve
water outlet from outside to inside, and it will be beyond repair
after knocking open, please pay attention to the installation
place, lest cause the inconvenience. Please do the moth proofing
for the knocked out hole, to avoid the pest processing into and
destroy the components.
4~8kW
Water Outlet
Fig.6-6
Fig.6-7
Fig.6-8
Fig.6-9
Fig.6-10
V.2
Содержание ETH-4VB
Страница 1: ...EAS THERMAL BIBLOCK MANUAL DE INSTALACI N Y MANUAL DE USUARIO MODELOS ETH 10VB ETH 12VB ETH 16VB V 2...
Страница 21: ...CONTROL POR CABLE CON PROGRAMACI N SEMANAL MANUAL DE INSTALACI N Y MANUAL DE USUARIO MODELO ECRTH V 2 V 2...
Страница 45: ...60mm B C A 25 V 2...
Страница 47: ...EAS THERMAL BIBLOCK INSTALLATION S AND OWNER S MANUAL MODELS ETH 10VB ETH 12VB ETH 16VB V 2...
Страница 80: ...V 2 WIRE CONTROL WITH WEEKLY PROGRAMMING OWNER S MANUAL MODEL ECRTH...
Страница 103: ...V 2 www easelectric es...