background image

3.4 Installation Caution

16

Since this machine adopts compulsory air inlet and exhaust, it is permissible to be installed in the 

bathroom, however, the exit of exhaust system must be extended outdoors, and the distance between 

the end of outdoor exhaust pipe and adjacent or other articles must be larger than 600mm.

This machine is not allowed to be installed outdoors to prevent damage of the heater caused by 

freezing of water.

A water inlet valve shall be installed at the water inlet pipe of the unit, so that the water supply can be 

switched off in repair.

The mounting position of the unit is made of a nonflammable material. If it is made of an inflammable 

or flame resistant material, a heatproof plate shall be used for heat insulation, whose distance from the 

wall shall be greater than 10mm.

The lower edge of the unit shall be about 1.5m above the ground, so that its combustion can be easily 

observed and its temperature adjusted.

A LPG user shall select a suitable, high-quality gas relief valve, whose specification shall not be less 

than 1.5m³/h to guarantee the gas pressure and flow input into the unit. ``

Natural gas users shall use a hard metal pipe with the same diameter as the gas inlet of the unit to 

reduce gas closure ande pressure loss.

There should be no inflammable or explosive material around the unit and the fume exhaust port, e.g., 

kerosene, gasoline, alcohol, paints, paper, clothes, etc.

Do not point the exhaust port directly to a nearby window when install the unit.

The unit shall not be installed where there is corrosive gas or article, and there should be no exposed 

wire, electric appliance or gas pipe above it, or any gas range or baking oven below it.

V.1

Содержание EMG11BT

Страница 1: ...o est ndar Calentador de agua a gas de combusti n dom stico Manual de Instrucciones Modelo EMG11BT EMG11NG EMG13BT EMG13NG Muchas gracias por comprar nuestro calentador de agua Antes de utilizar su ai...

Страница 2: ...n de Gas Natural 2014 30 UE Directivas para la compatibilidad electromagn tica EN 26 calentadores de agua en el sanitario equipados con quemador de gas atmosf rico con gas natural como combustible EN...

Страница 3: ...tar riesgos ADVERTENCIA No seremos responsables de ning n accidente que surja de un desmontaje no autorizado o de la falla en el funcionamiento de este manual de instrucciones 1 PRECAUCIONES 1 2 Preve...

Страница 4: ...ador solo puede usarse para fines generales pero no es adecuada para beber Prevenci n de accidentes el ctricos Desconecte el enchufe el ctrico antes de limpiarlo o realizar tareas de mantenimiento No...

Страница 5: ...8 0 14 0 8 0 0 2 10 8 22 9 5 88 19 4 10 14 0 8 0 0 2 10 230 I 2Alt 20 G20 45 22 0 11 5 25 10 1 88 10 14 0 8 0 0 2 Flujo de agua m ximo 2bar L min L min Flujo de agua m nimo 2bar 50 50 50 50 Hz I3P 37...

Страница 6: ...PT SK SI ES SE CH TR Conexiones Conexi n de gas Conexi n de agua fr a Conexi n de agua caliente Di metro de la tuber a de gases de combusti n D Temperatura m xima de tubos de escape QHi Longitud de la...

Страница 7: ...a Salida de agua Entrada de gas Quemador V lvula de liberaci n de presi n V lvula de decantado de agua Ensamblaje de la aguja de encendido V lvula proporcional de gas Transformador de voltaje Sensor d...

Страница 8: ...HV GHPDVLDGR DOWD OD YiOYXOD GH VHJXULGDG GHO FDOHQWDGRU GH DJXD SXHGH DOLYLDU OD SUHVLyQ DXWRPiWLFDPHQWH SDUD HYLWDU GDxRV HQ HO FDOHQWDGRU GH DJXD Conveniente filtro de agua extra ble 3DUD iUHDV GRQ...

Страница 9: ...os gases o propulsores l quidos y limpiadores dom sticos Si estas condiciones no se pueden garantizar se debe elegir otro lugar para la toma de aire 3 INSTALACI N DE LA UNIDAD 8 3 3 Modos de instalaci...

Страница 10: ...ctar directamente a la boquilla de la ducha y se debe instalar una v lvula de salida de agua como se muestra en la ilustraci n anterior ADVERTENCIA Esta unidad debe instalarse en interiores y no debe...

Страница 11: ...straci n Instalaci n del tubo de suministro y escape obligatorio de la unidad M s de 600mm M s de 300mm M s de 150 mm M s de 150 mm a Modo de instalaci n del escape superior Tornillo autorroscante Cod...

Страница 12: ...cantes b Modo de instalaci n del escape de la parte superior trasera 2 orificios de montaje para enchufe de pl stico con tornillo autorroscante 1 orificio de montaje para tornillos expansores Inclinac...

Страница 13: ...scante Como se muestra en la imagen siguiente ajuste los tornillos expansores para fijarlos cuelgue la unidad verticalmente y atorn llela con tuercas inserte tapones de pl stico debajo de este y atorn...

Страница 14: ...l stico debajo de este y atornille los autorroscantes Tornillo autorroscante Codo Tornillo autorroscante ST4 2 6 5 tres Sello de empaque Tubo de suministro y escape Inclinaci n hacia debajo de 3 2 ori...

Страница 15: ...Modo de instalaci n del escape de la parte superior trasera Inclinaci n hacia debajo de 3 Sello de empaque EMG11BT EMG11NG EMG13BT EMG13NG 3 8 90 100 orificio redondo atraviesa pared 1 orificio de mon...

Страница 16: ...manguera de goma especial para gas o un tubo r gido adecuado y una v lvula de descarga de gas Seleccione el tama o de tubo adecuado seg n el Cuadro 1 La longitud de la manguera de goma no debe exceder...

Страница 17: ...e ser mayor a 10mm El borde inferior de la unidad debe estar a alrededor de 1 5 m del suelo as la combusti n se puede observar de manera f cil y se puede ajustar la temperatura Un usuario LPG debe ele...

Страница 18: ...t culo conectado a tierra de manera confiable a la izquierda o a la derecha de la unidad Inserte el enchufe de la fuente de alimentaci n y enci ndalo Abra el interruptor principal de la v lvula de gas...

Страница 19: ...pida y continuamente Pulse la tecla ON OFF ENCENDI DO APAGADO la alarma desaparecer y la pantalla se cerrar pero el indicador de encendido no se apagar verde Utilice controladores de l nea m ltiple El...

Страница 20: ...a tecla de ON OFF ENCENDI DO APAGADO del mismo debe estar en la posici n OFF APAGADO antes de proceder con las siguientes operaciones Cierre la v lvula de salida de agua la unidad se detendr autom tic...

Страница 21: ...ntamiento el ctrico ni el m todo de drenaje anticongelante pueden evitar el congelamiento de las tuber as y v lvulas Todas las tuber as y v lvulas de la entrada de agua fr a hasta la salida de agua ca...

Страница 22: ...Retire el enchufe de alimentaci n cuando abra la carcasa de un calentador de agua No moje la toma de corriente con agua en uso para garantizar la seguridad 21 5 MANTENIMIENTO 6 SOLUCI N DE PROBLEMAS...

Страница 23: ...ulica inadecuada El quemador est bloqueado Baja El fuego no desaparece incluso despu s que el calentador se apag La llama se apaga cuando la unidad se configura en posici n Invierno El agua est demas...

Страница 24: ...a temperatura del agua incorrecto Entrada de aire fresco inadecuada Conducto de humo obstruido P ngase en contacto con el personal de mantenimiento P ngase en contacto con el personal de mantenimiento...

Страница 25: ...o tiene una garant a de reparaci n de dos a os a partir de la fecha de venta contra todo defecto de funcionamiento proveniente de la fabricaci n incluyendo mano de obra y piezas de recambio Para justi...

Страница 26: ...V 1 www easelectric es...

Страница 27: ...your water heater please read this manual carefully and keep it for future reference The diagram above is just for reference Please take the appearance of the actual product as the standard Domestic...

Страница 28: ...atural Gas Installation 2014 30 EU Directives for the electromagnetic compatibility EN 26 water heatersin the sanitaryequipped withatm ospheric gasburner with natural gasas fuel EN 50165 non electroni...

Страница 29: ...rder to avoid a hazard WARNING We shall not be liable for any accident arising from unauthorized disassembly or failure to operate on this instruction manual 1 CAUTIONS 1 2 Prevention of Gas Accident...

Страница 30: ...water supplied by the heater can only be used for general purposes but not suitable for drinking During ignition it is strictly forbidden to let the eyes close to the observation hole to examine the i...

Страница 31: ...utput Efficiency of energy sources Nominal Heat Input Q 88 26 10 8 9 5 88 22 19 4 Water supply pressure Max water pressure Min water pressure bar bar 10 0 2 14 0 8 0 14 0 8 0 0 2 10 8 22 9 5 88 19 4 1...

Страница 32: ...of nozzle mm unit 24 IPX4 C12 C32 IPX0 B22 C12 C32 B22 1 40 0 86 24 0 54 30 0 86 30 ERP Declare load profile Water heating energy efficiency class Water heating energy efficiency Daily gas consumptio...

Страница 33: ...r outlet Gas inlet Burner Pressure release valve Water draw off valve Ignition needle assembly Gas proportional valve Voltage transformer Water inlet temperature sensor Water outlet temperature sensor...

Страница 34: ...amage to the water heater Convenient Removable Water Filter For areas where the water quality is poor an easily removable water filter is provided specially for cleaning Brand new Ultra thin Appearanc...

Страница 35: ...solvents paints adhesives gasses or liquid propellants and household cleaners If these conditions are not able to guarantee another place should be chosen for the air intake 3 UNIT INSTALLATION 8 3 3...

Страница 36: ...ate The B22 gas water heater can not be installed in bathroom 9 WARNING The water outlet pipe cannot be connected to the shower nozzle directly and a water outlet valve must be installed as shown in a...

Страница 37: ...tration Installation of compulsory gas supply and exhaust pipe of the unit More than 600mm More than 300mm More than 150mm More than 150mm a Installation mode of topside exhaust Self tapping screw Elb...

Страница 38: ...screw down self tapping screws b Installation mode of top rear exhaust 2 mounting holes for self tapping screw plastic plug 1 mounting holes for expansion screws Incline downward by 3 Packing seal Con...

Страница 39: ...crew ST4 2 6 5 Self tapping screw As show in the figure below tap in expansion screws for fixation hang the unit vertically and screw it down with nuts insert plastic plugs below it and screw down sel...

Страница 40: ...nuts insert plastic plugs below it and screw down self tapping screws Self tapping screw Elbow Self tapping screw ST4 2 6 5 three Packing seal Supply and exhaust pipe Incline downward by 3 2 mounting...

Страница 41: ...tapping screws b Installation mode of top rear exhaust Incline downward by 3 Packing seal EMG11BT EMG11NG EMG13BT EMG13NG 3 8 90 100 round hole Wall through hole 1 mounting hole for expansion screws...

Страница 42: ...After installation check the unit with suds for gas leak b Connect the unit to the gas joint with G1 2 pipe thread When LPG is used connect the attached gas inlet hose joint to the gas supply pipe joi...

Страница 43: ...on whose distance from the wall shall be greater than 10mm The lower edge of the unit shall be about 1 5m above the ground so that its combustion can be easily observed and its temperature adjusted A...

Страница 44: ...METHODS OF USING 17 Receptacle shall be installed on the left or right side of the unit and must be grounded reliably Insert the power supply plug and switch on the power Open the main gas valve switc...

Страница 45: ...iple line controllers The priority principle will apply to the use of multiple line controllers whichever is stated first will have the priority while the power indicator of the controller with priori...

Страница 46: ...line controller the ON OFF key of the line controller shall be at the OFF position before you proceed with the following operations Close the water outlet valve the unit will stop automatically Close...

Страница 47: ...ating antifreeze method nor the antifreeze drainage method can prevent freezing of the pipes and valves All pipelines and valves from the cold water inlet to the hot water outlet shall be wrapped with...

Страница 48: ...open the cases of water heaters Pull out the power plug when opening the case of a water heater Do not wet the power socket with water in use to ensure safety 21 5 MAINTENANCE 6 TROUBLESHOOTING WARNIN...

Страница 49: ...t temperature sensor error A7 Water flow over the maximum value CA Exhaust Blockage CF Air Pressure Switch Wrong Connection C4 APS doesn t have pressure C6 Over temperature protection E1 Inlet tempera...

Страница 50: ...ater heater immediately and notify the professional maintenance department for repair The users shall not remove or repair the water heaters without prior permission otherwise an accident might occur...

Страница 51: ...ct disposal of their old appliance COMMERCIAL WARRANTY CONDITIONS OF COMMERCIAL WARRANTY This product has a repair warranty of two years from the date of sale against any malfunction from the manufact...

Страница 52: ...V 1 www easelectric es...

Отзывы: