background image

Commissioning

4.

3.2

3.3

Step 1

Step 2

Step 3

Unscrew the swivel nut from 
the threaded sleeve,
then thread the swivel nut and 
threaded sleeve over 
the AC cable

Insert the conductor into a suitable ferrule 
acc. to DIN 46228-4 and crimp.
Insert the crimped conductors, L, N and PE 
into corresponding terminals and tighten 
the screws (torque 0.6±0.1N·m).

Assemble the locking cap, 
threaded sleeve and swivel 
nut together.

Screw the AC connector and 
tighten firmly into socket.

 Approx. 60mm

For “L1” , “L2”,“L3”and “N”

7-9mm

4....6mm²

φ

12

-1

8

m

m

 Approx. 65mm

1

2

1

2

L

N

PE

DC Wire Assembly and Connection

Note: According to  AS/NZS 5033, PV arrays for installation on domestic 
dwellings shall not have PV array maximum voltages greater than 600V.

1

Wi-Fi/GPRS Connection

 (Optional)

3.4

The stick is included in the scope of delivery as an option.

3.4.1 Tighten the stick into the COM1 port. Make sure the stick is 
securely connected.
3.4.2 For the connection and configuration of the Wi-Fi stick please refer to 
<Wi-Fi stick User manual> .

2

1

1

3.5

RS485/Smart Meter/DRED Connection

Step 1

DRED

Meter

R   485

S

DRED

Meter

R   485

S

DRED

METER

RS485

or

or

Ap

pr

ox

.6

0m

m

Step 2

Step 3

B

A

1

2

screwdriver type: Blade 0.4 x 2.5

RS485/METER  connection

Connect the crimped cables to RS485 / Meter terminals/

DRED

and secure by (blade 0.4x2.5) screwdriver

123 4 5 6 78

Pin1:DRM1/5
Pin2:DRM2/6
Pin3:DRM3/7
Pin4:DRM4/8

Pin5:RefGen
Pin6:Com/DRM0
Pin7:N/A
Pin8:N/A

 8

D

RED

 

connection

R   45 Plug

J

R   45 Plug

J

Step 4

T

ighten

 

the

 

nut

 

to

 

prevent

 

the

 

cable

 

from

wobbling,

 p

ut on the COM

2

 

sealing plate and 

firmly tighten the screws . 
(Screwdriver type: T25; Torque: 2.5 Nm)

1

2

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

click

click

10

7mm

7mm

PV1-F/UL-ZKLA/USE2

PV1-F/UL-ZKLA/USE2

Assemble the connectors

2.6-2.9 N·m

Positive

Negative

Assemble the 

 cable ends

D4

Positive terminal

Negative terminal

Crimp pliers to cable ends

Note: Don't crimp this part!

Assemble the 

 cable ends

MC4

Positive terminal

Negative terminal

www.

easelectric.es

EAS ELECTRIC SMART TECHNOLOGY, S.L.

Address: 

P.I. Codonyers, C/Principal, 4 46220 Picassent (Valencia, SPAIN)

Содержание EINSOLAR5Y

Страница 1: ...ije la placa de montaje con los tornillos y los pernos de expansión incluidos en los accesorios de montaje 3 Monte el inversor en la placa de montaje 4 Compruebe ambos lados del disipador de calor y asegúrese de que el inversor está instalado de forma estable 5 Use tornillos M5 con par de apriete de 2 5Nm para unir las aletas del disipador de calor a la placa de montaje 6 Es recomendable incorpora...

Страница 2: ...miento AVISO Compruebe la polaridad de los strings FV Compruebe que la tensión de circuito abierto es inferior al límite de entrada del inversor 600V Retire los tapones sellantes de los terminales FV Si hay un terminal que no se vaya a usar séllelo con un tapón Compruebe si los cables están bien instalados tirando hacia fuera Paso 6 Introduzca los conectores en el terminal hasta que oiga un clic A...

Страница 3: ... 5 4 7 6 RS485 DRED Dimension W H D 425 346 160mm Packing List Inverter Mounting Bracket Mounting Accessories Documents 1 1 1 2 1 1 1 2 Wi Fi GPRS stick optional 3 1 1 Use the mounting paper guide to mark holes on the wall Drill three holes in the marked position of 10mm diameter and 70mm depth 3 1 2 Fix the expansion bolts and mount the main bracket with the screws in mounting accessories 3 1 3 A...

Страница 4: ...guration of the Wi Fi stick please refer to Wi Fi stick User manual 2 1 1 3 5RS485 Smart Meter DRED Connection Step 1 DRED Meter R 485 S DRED Meter R 485 S DRED METER RS485 or or Approx 60m m Step 2 Step 3 B A 1 2 screwdriver type Blade 0 4 x 2 5 RS485 METER connection Connect the crimped cables to RS485 Meter terminals DRED and secure by blade 0 4x2 5 screwdriver 123 45 678 Pin1 DRM1 5 Pin2 DRM2 ...

Отзывы: