Earthsafe EVACLEAN PX200ES Скачать руководство пользователя страница 2

1. Removal of 32 oz. Tank.  Rotate the dial of the tank lock towards

the unlock position. Pull the tank release ring and carefully

remove the tank. Hold on to the tank while pulling the ring or the

tank may fall.

1

3.  Inserting tank back into sprayer. Place the tank on a flat surface,

and align the groves of the tank with the sprayer.  Insert the

tank into the sprayer until you hear the click of the release ring

locking back into place. Rotate the dial of the tank lock towards

the lock position to secure the tank in place.

6.  Care instructions. 

Never store the sprayer with a full tank.

Remove tank, prior to storing the sprayer, and use the tank lid to

seal any remaining PurTabs solution for the next use. Regularly

flush the sprayer and nozzle by filling the tank with warm water

and spraying each nozzle setting for approximately 30 seconds.

Evacuate water fully from sprayer tubing prior to storing.  Wipe

nozzle area dry after each use.

4. Electrostatic on/off. Turn on the electrostatic component by

sliding it to the “on” position.

2.  Diluting PURTABS into the tank. Fill the tank up to the fill line

with warm water. Dro

p the number of 

tablets

 needed

 into the 

tank.  Close the tank with the lid, and wai

t

 for complete 

dilution prior to re-inserting the tank.

 Check

 

visually to 

confirm dilution.

 Label the date of dilution on the tank. 

Please

 

reference the dilution table for

 concentrations

.

5.  Optimal distance. To ensure optimal electrostatic performance

always keep your hand firmly wrapped around the handle and in

contact with the ground strap. Keep a distance of 2-3 feet from

desired surface. Pull the trigger and spray.

1

  Locking the trigger: Press on the trigger lock to engage the lock prior to removing the tank, storing  

the sprayer, and in between uses.

7.  Nozzle care. “Do not touch or insert foreign

object into the nozzle to avoid electric shock”. If

your single  becomes clogged, soak in hot soapy

water and blow out with pressurized air to

remove blockage. When not properly cleaned,

the sprayer nozzle residual chemical deposits

build up. Deposit build up results in decreased

bar pressure and decreased spray patterns.

© EarthSafe Chemical Alternatives, LLC. All rights reserved.

(reference nozzle  

care instructions)