background image

OPERATOR INSTRUCTIONS ANd PARTS 

WP6520 & WP6530 Water Pumps

Page 2

800-345-6007

GetEarthquake.com

GetEarthquake.com

Please read and save these instructions.  

Read carefully before attempting to as-

semble, install, operate or maintain the 

product described.  Protect yourself and 

others by observing all safety information.  

Failure to comply with instructions could 

result in personal injury and/or property 

damage!  Retain instructions for future 

reference.

description

Earthquake Pumps are general use centrifugal 
water pumps.

Safety Guidelines

This manual contains information that is very 
important to know and understand.  This infor-
mation is provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS.  To help recognize this 
information, observe the following symbols.

DANGER

danger indicates an imminently hazard-

ous situation which, if not avoided, will 

result in death or serious injury.

WARNING

Warning indicates a potentially hazardous 

situation which, if not avoided, could result 

in death or serious injury.

CAUTION

Caution indicates a potentially hazardous 

situation which, if not avoided, may result 

in minor or moderate injury.

NOTICE

Notice indicates important information, 

that if not followed, may cause damage to 

equipment.

GENERAL SAFETy INFORMATION

1. Know the pump application, limitations, and 
potential hazards.  Read these rules and the 
instructions carefully.  Failure to follow them could 
cause serious bodily injury and/or property dam-
age.

DANGER

Never run engine in an enclosed area.  Ex-

haust gases contain deadly poisonous car-

bon monoxide, which has no odor or taste.

WARNING

do not use to pump flammable or explo-

sive fluids such as gasoline, fuel oil, kero-

sene, etc.  do not use in flammable and/or 

explosive atmospheres.  Pump should only 

be used to pump water.  Failure to follow 

this warning can result in personal injury 

and/or property damage.

2. Observe all safety precautions for the handling 

of the fuel.

WARNING

do not refuel a hot engine.  Fuel spilled on 

a hot engine could result in a fire or explo-

sion.  do not refuel a running engine.

3. Pump should be located and should rest on a 

level solid foundation.  Do not suspend pump 
by means of the discharge pipe.

NOTICE

Be sure pump is on secure footing so it 

doesn't fall over.

4. Do not use torches or apply excessive heat, fire 

or flames to this pump as an explosion may 
result.

Содержание WP6520

Страница 1: ...GetEarthquake com GetEarthquake com WP6520 WP6530 WATER PUMPS OPERATOR S MANUAL OMWP65 R070209 2009 Ardisam Inc All Rights Reserved Printed in USA WP6520 ...

Страница 2: ...ich if not avoided may result in minor or moderate injury NOTICE Notice indicates important information that if not followed may cause damage to equipment General Safety Information 1 Know the pump application limitations and potential hazards Read these rules and the instructions carefully Failure to follow them could cause serious bodily injury and or property dam age DANGER Never run engine in ...

Страница 3: ...pecified below 1 The pump should be placed as close as pos sible to the liquid being pumped A pump with 20 foot suction lift will not remove water as quickly as a pump with 5 foot suction lift Fig ure 1 2 Suction hose and fitting must be airtight NOTICE An air leak in the suction line may prevent priming of the pump Use of thread seal ant is recommended Suction lines must be reinforced hose or rig...

Страница 4: ...stallation Failure to do so may cause piping to break pump to fail etc all of which can result in property damage and or personal injury All suction connections must be airtight If the pump won t prime check for leaks in the suction piping or fittings If flexible suction hose is used instead of pipe use reinforced hose with a two inch inner diameter Non reinforced flexible hose may collapse from t...

Страница 5: ...rk must be sent directly to Ardisam Inc or one of our authorized service centers and performed by them To obtain warranty service and replacement instructions contact our customer service department at 800 345 6007 M F 8 00am 5 00pm CST or by writing to Ardisam Inc 1690 Elm Street Cumberland WI 54829 All items must be shipped prepaid Ardisam Inc will at no charge repair or replace at their discret...

Страница 6: ...8 X 25 HHFCS 4 1 SOLD ONLY AS 913350 PUMP GASKET SERVICE KIT 2 INCH 2 SOLD ONLY AS 913346 PUMP SEAL SERVICE KIT 2 INCH NS not shown WP6530 PUMP PARTS LIST 3 INCH QTY EA 1 913320 PUMP OUTBOARD CASE 3 INCH 1 2 913321 PUMP INBOARD CASE 3 INCH 1 3 913322 PUMP DISCHARGE FLANGE 3 INCH 1 4 913323 PUMP INLET FLANGE 3 INCH 1 5 913324 PUMP HAND NUT 3 INCH 2 6 913351 PUMP IMPELLER 3 INCH 1 7 913326 PUMP VOLU...

Страница 7: ...Page 800 345 6007 OPERATOR INSTRUCTIONS and parts WP6520 WP6530 Water Pumps GetEarthquake com GetEarthquake com ...

Страница 8: ...Earthquake Division of Ardisam Inc 1690 Elm Street Cumberland Wisconsin 54829 800 345 6007 Fax 715 822 2223 E mail info ardisam com ...

Отзывы: