Level Controls

This feature adjusts the maximum desired output of the associated zone to prevent overpowering of small 
speakers.
Note: This knob is by-passed when its zone selector switch(feature 2) is set to BUS.

LOCAL/BUS Switch

It switches the audio source between LOCAL and common BUS. In LOCAL mode, the zone acts independently 
from the rest of system by only amplifying the information fed through the associated RCA inputs. In BUS mode, 
that particular zone will amplify the signal fed through the main BUS input (page 11 - feature 9).

Audio RCA Input

Individual stereo RCA inputs to drive signal into associated zones. Both RCA’s, LEFT and RIGHT, are active 
when the STEREO/MONO switch is set to MONO (feature 4). Thus, you can use either RCA inputs. 
Note: This RCA input also serves as an Auto Signal Sensing whenever there is a signal greater than 12mV 
present. 

STEREO/MONO Selector

Switches the amplifier’s output between STEREO or MONO.

·

  In 

STEREO

  mode,  the  LEFT  and  RIGHT  outputs  operate  independently  at  75  Watts  per  channel  at  4Ù 

speaker load. Level, Gain, Auto Turn ON and MUTE are all common to both.

·

 In 

MONO

 mode, the LEFT and RIGHT stereo signals are summed internally for a single high power output. 

You can drive two 4Ù speakers in this mode or a single 4Ù Bridged for maximum power of 150WRMS. Also, if 
the source is already a mono signal, you may use either RCA, LEFT or RIGHT.

Keypad/Zone Connector

With  four  (4)  removable  conductors  (IR  IN,  STATUS,  GROUND  and  CI–Control  Input),  these  screw  type 
connector accepts wire sized from 24 to 12 AWG. We recommend using the CAT5, CAT5E, CAT6 or CAT6E 
wires. 

·

 

IR IN

 – receive all types of IR signal transmitted through the Earthquake Keypad. It allows Volume up/down 

and mute function at the local amplifier. Also, it allows most IR signal to pass through the four built-in IR 
repeaters of the Cinénova 16IR (page 11 - feature 12). 

·

 

STATUS 

–  this  connector  delivers  DC  signal  to  the  Keypad’s  LED  status  indicator  when  the  associated 

amplifier is ON.

·

 

GROUND

 – for the Keypad.

·

 

CI

 – Control Input is the communicator line used to control amplifier’s ON/OFF (Mute) status manually.

Fault Fuse Indicator (FFI)

This LED indicates the safe operation of the amplifier’s internal circuit for the associated zone. Under normal 
condition, this LED is off. When it is lit, the fuse on the internal circuit of that associated zone is blown, usually 
due to a shorted circuit. Simply replace with the same size fuse. For your convenience, we’ve included four (4) 
additional fuses with every amplifier.

Speaker Terminals

This screw type connector with four (4) removable conductors accepts wire sizes from 16 to 12 AWG. Observe 
the Polarity printed on the terminal. Observe the printed instruction above and below the Speaker terminal.

1

2

7

3

4

5

6

Rear Panel Map - LOCAL

1

2

3

4

5

6

7

STATUS
GROUND

IR IN

BUS

MONO

CI

FFI

0.2V

3V

LEVEL

1V

BRIDGE

1

STEREO

LOCAL

FFI

L

M

R

L

M

R

L

M

R

L

M

R

L

M

R

L

M

R

L

M

R

L

M

R

SPEAKER OUTPUT

L

L

L

L

L

L

L

L

R

R

R

R

R

R

R

R

L

R

L

R

FUSE

110-120VAC-60Hz
220-240VAC-50Hz

Earthquake Sound

10

Содержание Cinenova IR16

Страница 1: ...Will Move You 8 ZONES MULTI SOURCE IR DRIVEN AMPLIFIER USER S MANUAL Cin nova 16 IR Earthquake Sound Corporation 2727 McCone Avenue Hayward CA 94545 Phone 510 732 1000 Fax 510 732 1095 www earthquakes...

Страница 2: ......

Страница 3: ...tion Unpacking 4 5 6 7 Specifications 17 Product Warranty 19 Troubleshooting Maintenance 18 Front Rear Panel Overview Front Panel Map Rear Panel Map LOCAL Rear Panel Map BUS Keypad Remote Map Special...

Страница 4: ...not correctly performed or adhered to could result in injury or death Calls attention to a procedure practice condition or the like that if not correctly performed or adhered to could result in damag...

Страница 5: ...o not install near any heat sources such as radiators heat been spilled or objects have fallen into the apparatus the registers stoves or other apparatuses that produce heat apparatus has been exposed...

Страница 6: ...s a LOCAL BUS input audio selector 12V DC trigger Individually driven amplifier blocks each block is driven by a discrete complementary output classA B stage with selected components Individual power...

Страница 7: ...enix pad connectors 1 16 channelAmplifier Cin nova 16 included components IR There are several factors to consider before installing the Earthquake Sound Cin nova IR16 system What are the intended lis...

Страница 8: ...C 18 375 466 5mm 17 431mm 19 482 6mm 4 101 5mm 6 876 174 5mm Front Rear Panel Overview 8 Earthquake Sound L M R L M R L M R L M R L M R L M R L M R L M R SPEAKER OUTPUT L L L L L L L L R R R R R R R R...

Страница 9: ...ut unless this LED is ON Note When using another device to turn on the Cin nova IR16 amplifier this LED will come on when external device sends DC signal between 5 and 28V DC to the back ofTrigger con...

Страница 10: ...removable conductors IR IN STATUS GROUND and CI Control Input these screw type connector accepts wire sized from 24 to 12 AWG We recommend using the CAT5 CAT5E CAT6 or CAT6E wires IR IN receive all t...

Страница 11: ...n 5V DC and up to 28V DC This remote turn on option does not override the auto signal sensing turn on feature of this amplifier Note The front power switch page 9 feature 1 must be left in the OFF pos...

Страница 12: ...eature 12 NOTE One Keypad is capable of driving multiple zones Simply connect the CI wire of those zones in parallel For example if you want to use the Keypad from zone 1 to control zone 1 through 5 r...

Страница 13: ...hannel is equipped with a thermal sensor designed to Bus input shut the amplifier down when it overheats Overheating is not typical It only occurs if the amplifier is over driven with low impedance sp...

Страница 14: ...te that you will need to use your source remote aim it at the pad and it will deliver the IR signal to the source Mono Stereo input control You must switch to MONO when the amplifier is wired for MONO...

Страница 15: ...the back of the amplifier that can be connected to the source IR sensor Once connected the user can control the source from the room the illustration below has a DVD player connected to the IR repeate...

Страница 16: ...R L M R L M R SPEAKER OUTPUT L L L L L L L L R R R R R R R R L R L R FUSE 110 120VAC 60Hz 220 240VAC 50Hz 75 Watts RMS Per Channel Background room s 6 Zones STEREO 150 Watts RMS Per Channel 1 High Pow...

Страница 17: ...k 70 k 92dB 12 minutes 86dB 50V sec 29 200 8 5 5 28 VDC 15 Amp 120VAC 60Hz 10 Amp 220VAC 50Hz 115V T15A 250V 230 T10A 250V 3 AG type slow blow 5A 250V 61 7 lbs 28 kg 66 1 lbs 30 kg Date of purchase S...

Страница 18: ...volume level to prevent damage to the unit Turn amplifier ON and circuit breaker shuts down This can either be a short in amp or poor circuit breaker in the house Plug amplifier into another outlet o...

Страница 19: ...to resolve the problem over the phone thus warranty Customer will be charged a minimum of one 1 hour of labor at the eliminating the need to ship the product ongoing rates plus shipping charges back...

Страница 20: ...he right to amend details of the specifications without notice Copyright Earthquake Sound Corporation Earthquake Sound Corporation 2727 McCone Avenue Hayward CA 94545 Phone 510 732 1000 Fax 510 732 10...

Отзывы: