manualshive.com logo in svg
background image

HCM-410CP-IM (12/15) 

 

Copyright 2015 Earthlinked Technologies, Inc 

 

Hybrid Cooling Module 

Models HCM-1836C and HCM-4272C 

Installation Manual 

for R-410A 

 

CONTENTS 

PAGE 

Pre-Installation 

Installation 

  Placement 

  Refrigerant Connections 

  Electrical and Start-Up 

  Fan Speed Control 

10 

 

 

 

 

 

Содержание HCM-1836C

Страница 1: ...inked Technologies Inc Hybrid Cooling Module Models HCM 1836C and HCM 4272C Installation Manual for R 410A CONTENTS PAGE Pre Installation 3 Installation 5 Placement 5 Refrigerant Connections 7 Electri...

Страница 2: ...within this manual Failure to provide installation and service by an ETI authorized technician in a manner consistent with this manual will void the limited warranty coverage for the EarthLinked syst...

Страница 3: ...e table below to determine the required coupling sizes COMPRESSOR UNIT HCM MODEL MATCH Compressor Unit Model Hybrid Cooling Module Vapor Line Set Size OD in Model HCM Connections OD In R 410A 018 1836...

Страница 4: ...Connections Tube OD inches Sound dB A Net Weight Lbs Coil H W D Inlet Outlet Rows Fins inch Face Area Sq Ft 25 7 8 36 17 3 8 7 8 7 8 52 0 95 2 15 7 0 Fan Electrical Type CFM RPM Dia inches Power Fan...

Страница 5: ...tside the building Figure 2 Hybrid Cooling Module Placement in EarthLinked System Location Requirements for the Hybrid Cooling Module 1 Within 20 Feet of the earth loop line set Minimize refrigerant l...

Страница 6: ...le for securing unit 6 Where conditions or local codes require the Hybrid Cooling Module to be attached to a mounting pad or frame tie down bolts should be used to fasten through the holes provided in...

Страница 7: ...e run parallel to and within 10 Feet of the building foundation or basement wall both lines are to be insulated with wall thickness Armaflex or InsulTube tubing insulation cased within a PVC pipe The...

Страница 8: ...ections All refrigerant piping joints and connections in the EarthLinked heating and cooling system including the Hybrid Cooling Module line sets and earth loop system are to be brazed with 15 silver...

Страница 9: ...The Hybrid Cooling Module contains a pressure actuated fan speed control that has been factory set for a pre determined R 410A system condensing pressure 4 Check all wiring and electrical connections...

Страница 10: ...1 4 Turn 12 2 Figure 6 R 410A Condensing Pressure and Temperature Information If it is necessary to adjust the full speed fan pressure setting in the field the Hybrid Cooling Module pressure control m...

Страница 11: ...ld Adjustment Procedure After adjustment has been made install the sealing plug and replace and fasten the control panel cover prior to restoring power to the Hybrid Cooling Module The Hybrid Cooling...

Отзывы: