background image

ACM-410CP-IM (05/13) 

 

Page 2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disclaimer 

The EarthLinked

®

 Auxiliary Cooling Module is sold as a system component part and must be 

properly sized and matched to the system compressor unit to provide the intended performance 
and safe operation of the system.  This component must be installed and serviced by a trained 
technician who has successfully completed the ETI training class and passed the final examination. 
Installation and service must be made in accordance with the instructions set forth within this 
manual and the current 

EarthLinked

®

 Heating and Cooling System Installation, Operation and 

Maintenance Manual. 

Failure to provide installation and service by an authorized, trained installer in a manner consistent 
with this manual will void the limited warranty coverage for the EarthLinked

® 

system.

 

Earthlinked

 

Technologies shall not be liable for any defect, unsatisfactory performance, damage or 

loss, whether direct or consequential, relative to the design, manufacture, construction, application 
or installation of other components in the EarthLinked

® 

system. 

 

 
 
 
 
 
 
 
 
 

Earthlinked Technologies, Inc. 

4151 South Pipkin Road 

Lakeland, Florida 33811 

tel. 863-701-

0096 ● fax 863-701-7796 

info@earthlinked

.com ● 

www.earthlinked.com

 

Содержание ACM-1836C

Страница 1: ...echnologies Inc EarthLinked Auxiliary Cooling Module Models ACM 1836C and ACM 4272C for R 410A Installation Manual CONTENTS PAGE Pre Installation 3 Installation 5 Placement 5 Refrigerant Connections 7...

Страница 2: ...s manual and the current EarthLinked Heating and Cooling System Installation Operation and Maintenance Manual Failure to provide installation and service by an authorized trained installer in a manner...

Страница 3: ...e models with EarthLinked compressor unit models Application of the Auxiliary Cooling Module ACM to EarthLinked systems will require the use of two 2 field supplied Type ACR copper couplings to match...

Страница 4: ...Connections Tube OD inches Sound dB A Net Weight Lbs Coil H W D Inlet Outlet Rows Fins inch Face Area Sq Ft 25 7 8 36 17 3 8 7 8 7 8 52 0 95 2 15 7 0 Fan Electrical Type CFM RPM Dia inches Power Fan...

Страница 5: ...igerant line set vapor tube outside the building Figure 2 Auxiliary Cooling Module Placement in EarthLinked System Location Requirements for the Auxiliary Cooling Module 1 Within 40 Feet of the earth...

Страница 6: ...e EL3648 3 36 x 48 x 3 Plastic drillable for securing unit 7 Where conditions or local codes require the Auxiliary Cooling Module to be attached to a mounting pad or frame tie down bolts should be use...

Страница 7: ...he Auxiliary Cooling Module to the earth loop line set If the lines to and from the Auxiliary Cooling Module are to be run parallel to and within 10 Feet of the building foundation or basement wall bo...

Страница 8: ...tions All refrigerant piping joints and connections in the EarthLinked heating and cooling system including the Auxiliary Cooling Module line sets and earth loop system are to be brazed with 15 silver...

Страница 9: ...und wire to the Auxiliary Cooling Module as shown in Figure 5 Figure 5 Auxiliary Cooling Module Field Wiring 3 The Auxiliary Cooling Module contains a pressure actuated fan speed control that has been...

Страница 10: ...ure Change psig Condensing Temperature Change F 448 125 1 4 Turn 12 2 Figure 6 R 410A Condensing Pressure and Temperature Information If it is necessary to adjust the full speed fan pressure setting i...

Страница 11: ...Adjustment Procedure After adjustment has been made install the sealing plug and replace and fasten the control panel cover prior to restoring power to the Auxiliary Cooling Module The Auxiliary Cooli...

Отзывы: