EarthCore ISOKERN ISOFLAME ISF24LB Скачать руководство пользователя страница 16

ISFOLAMES LINEAR BURNER 

 

2/2021 

16 

 

Burner Lighting Instructions 

INSTALLER INSTRUCTIONS 

It is required that the set of safety instruction labels that have been supplied with the appliance be affixed to the 

operation and control points of the appliance. It is the installers responsibility to ensure these warnings are properly 

affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this 

appliance

 

PRE-LIGHTING CHECKLIST 

Be sure to check these items before the initial lighting of the appliance: 

 

Gas pressure has been checked  carefully 

 

All gas fittings have been checked for  leaks. 

 

All clearances to combustibles have been  met 

 

All combustibles materials have been removed from the area in front of the appliance. 

 

All vented areas of the appliance face are unobstructed. 

 

House is ventilated to clear initial paint curing odors 

 

All packaging materials have been removed from the appliance. 

 

While appliance is cool, fingerprints or other marks have been cleaned from any plated surfaces with denatured 

alcohol and a soft cloth. Marks left on these surfaces may become permanent into the finish if not removed prior 

burning the unit. 

 

WARNING!!!: 

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY 

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 

SAFETY INSTRUCTIONS 

A.

 

This appliance is equipped with an ignition device which  automatically lights the pilot. Do NOT try to light the pilot by 

hand. 

B.

 

BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor. 

WHAT TO DO IFYOU SMELL GAS

 

Do not try to light any appliance. 

 

Do not touch any electric switch; do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire department. 

 

C.

 

If any portion of this appliance does not operate as the instructions indicate, do not try to repair it, call a qualified 

service technician. Do not use tools. Force or attempted repair may result in a fire or explosion. 

D.

 

Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to 

inspect the appliance and to replace any part of the system and any gas control which has been under  water. 

 

OPERATING INSTRUCTIONS 

Terminal X4 on module serves as Main Power switch. When X4 is jumpered, the Battery Holder Wall Switch functions 

as a burner and pilot override switch. When in the 

OFF

 position, it will not let the burner or pilot be turned on by the 

remote. When in the 

ON

 position the pilot and burner will initialize immediately. When in the 

REMOTE

 position, it 

gives the remote full control over burner and pilot functions. 

 

NOTE:

 See Remote Control System on pages 15-16 for remote specific operating instructions.

 

 

TO TURN OFF GAS TO APPLIANCE 

1)

 

Turn the burner ON/OFF switch to “OFF.”

 

2)

 

Turn off all electric power to the appliance if service is to be performed.

 

3)

 

Close the main line gas shut-off  valve.

 

 

WARNING!!!: OPERATION OF THIS APPLIANCE WHEN NOT CONNECTED TO A PROPERLY INSTALLED AND 

MAINTAINED VENTING SYSTEM CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND POSSIBLE 

DEATH. 

Содержание ISOKERN ISOFLAME ISF24LB

Страница 1: ...ual may change without prior notification PFS Report No F19 161 Issued February 2021 Revision 000 2020 Earthcore Industries LLC THESE FIREPLACES ARE DESIGNED FOR USE WITH PROPANE LP OR NATURAL GAS NG...

Страница 2: ...5 Isoflames Linear Burner Components List 6 Isoflames Linear Burner Specifications 7 Gas Line Valve Box Installation 8 Burner Installation 10 Burner Installation 11 Burner Assembly Connection 12 Burne...

Страница 3: ...pliance must be isolated from the gas piping system by closing its equipment shutoff valve during any pressure testing of the supply piping system at test pressures equal to or less than 1 2 psi 3 5 k...

Страница 4: ...r s warranty listings and approvals 25 The ISOFLAMES Linear Burner system is not intended to heat an entire home or to be used as a primary heat source 26 Children and adults should be alerted to the...

Страница 5: ...noxide Poisoning Early signs of carbon monoxide poisoning resemble flu symptoms including headaches dizziness or nausea If you have these signs the fireplace may not have been installed properly get f...

Страница 6: ...1 1 2 Pilot Assembly natural gas Pilot Assembly propane ISF E PAN ISF E PAP 1 1 3 Gas Valve natural gas Gas Valve propane ISF E GVN ISF E GVP 1 1 4 Control module remote receiver ISF E CM 1 5 Battery...

Страница 7: ...ear High Low High Low ISF24LB 17 5 16 36 25 36K 25K 32K 24K ISF36LB 17 5 16 48 37 54K 38K 48K 36K ISF60LB 17 5 16 72 61 90K 63K 80K 60K ISF72LB 17 5 16 84 73 108K 75K 96K 72K ISF96LB 17 5 16 108 97 10...

Страница 8: ...before starting installation or service 5 Make sure gas piping is pressure tested before control is connected High pressure can damage the control causing a hazardous condition 6 Make sure piping is c...

Страница 9: ...talled must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 If not installed and maintained in accordance with t...

Страница 10: ...1 4 and the length shall extend the entire width of firebox If the gas supply pipe from the external mounted valve is brought into the cavity through the sidewall of the firebox the cavity must exten...

Страница 11: ...flex connector to the gas supply 8 Avoid creating kinks in the flex connector 9 Make sure all connections are tightly secured 10 Before replacing the removed burner top from step 4 locate the perforat...

Страница 12: ...ISFOLAMES LINEAR BURNER 2 2021 12 Burner Assembly Connection 24 Burner Connection ISF36LB 36 Burner Connection ISF36LB ISF36LB Box No Part No Qty 4 E 18BP4 1 8 E 12BP1 1 4 8...

Страница 13: ...2 2021 ISOFLAMES LINEAR BURNER 13 48 Burner Connection ISF48LB 60 Burner Connection ISF60LB ISF60LB Box No Part No Qty 1 E 18BP1 1 4 E 18BP4 1 6 E 18BP6 1 4 6 1...

Страница 14: ...ISFOLAMES LINEAR BURNER 2 2021 14 72 Burner Connection ISF72LB ISF72LB Box No Part No Qty 4 E 18BP4 1 5 E 18BP5 1 9 E 12BP2 1 10 E 12BP3 1 13 E BPC 1 5 10 13 9 4...

Страница 15: ...2 2021 ISOFLAMES LINEAR BURNER 15 96 Burner Connection ISF96LB ISF96LB Box No Part No Qty 2 E 18BP2 1 3 E 18BP3 1 9 E 12BP2 1 10 E 12BP3 1 11 E 12BP4 1 12 E 12BP5 1 13 E BPC 1 13 3 10 12 9 2 11...

Страница 16: ...area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electric...

Страница 17: ...d the wall switch plate Correctly align polarity 3 On the wall switch place the three position slider switch in the REMOTE position 4 On the wall switch front cover insert the end of a paper clip or o...

Страница 18: ...wn Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while th...

Страница 19: ...ff valve is in ON position Pilot won t stay ignited Flame sensor obstruction Remove any obstruction near pilot igniter and flame sensor Loose pilot connections Check pilot wiring assembly is tightly s...

Страница 20: ...GLASS 10 LB JAR RFG 10 KD 1 2 REFLECTIVE KRYSTALLO DIAMOND FIRE GLASS 10 LB JAR RFG 10 AD 1 2 REFLECTIVE AMBER DIAMOND FIRE GLASS 10 LB JAR Glass Media will be included with the Isoflames Linear Burn...

Страница 21: ...Isokern Maximus Linear Fireplace Western Driftwood Cast Concrete Western Driftwood 36 Set For the 82L48 Fireplace ISF L 36LGC Western Driftwood 60 Set For the 82L72 Fireplace ISF L 60LGC Western Drift...

Страница 22: ...ISFOLAMES LINEAR BURNER 2 2021 22...

Страница 23: ...of this warranty the party to whom this warranty is extended shall notify ISOKERN 6899 Phillips Industrial Blvd Jacksonville Florida 32256 in writing by registered mail within thirty 30 days followin...

Отзывы: