27 of 39
Dated 17/09/19 V1.2
ESP-HC-DHW 11DC
ESP-HC-DHW 17DC
07
DIP switch input state
0(air source), 1(water source)
08
DIP switch input state
0(DHW invalid), 1(DHW valid)
09
DIP switch input state
0(G1 valid), 1(G1invalid)
10
High pressure switch state
1(On), 0(Off)
11
Over current protection switch
1(On), 0(Off) not valid
12
Low pressure switch state
1(On), 0(Off)
13
Inner water flow switch (for AH, GH)
1(On), 0(Off)
14
External water flow switch (for GH)
1(On), 0(Off)
15
Second high pressure switch state
1(On), 0(Off)
19
Compressor running Hz
Inverter: Show actual frequency
20
Outdoor fan motor
1:running, 0:stop
21
Bent axle heater
1(On), 0(Off)
22
Four way valve
1(On), 0(Off)
23
Bypass valve
1(On), 0(Off)
24
1 electrical valve
1(On), 0(Off)
25
2 electrical valve
1(On), 0(Off)
26
3 electrical valve
1(On), 0(Off)
27
1 electrical heater 1
1(On), 0(Off)
28
2 electrical heater 2
1(On), 0(Off)
29
C4 water pump
1(On), 0(Off)
30
C5 water pump
1(On), 0(Off)
31
C6 water pump
1(On), 0(Off)
32
Accumulation days since last antibacterial
0-99
33
Cooling setting temp
Real setting temp
34
Heating setting temp
Real setting temp
35
Hot water setting temp
Real setting temp
36
Anti-bacterial setting temp
Real setting temp
37
Outdoor modular temp
-30~97° C
38
Outdoor back temp
-30~97° C
39
Inner pipe temp
-30~97° C
40
Expansion valve open degree
41
Water source side inlet water temp
-30~97° C
42
Water side leaving temp
-30~97° C
43
Solar water tank temp
-30~97° C
44
Inner pipe temp
Entrance of the plate heat exchanger
45
Room temp display
46
Home optimization target temp
Calculation
parameter A
Whilst Checking Parameters, particular care should be taken to ensure
that they are not changed.
Содержание ESP-HC-DHW 11DC
Страница 2: ...Dated 17 09 19 V1 2 ESP HC DHW 11DC ESP HC DHW 17DC...
Страница 31: ...30 of 39 Dated 17 09 19 V1 2 ESP HC DHW 11DC ESP HC DHW 17DC 5 2 System Schematic...
Страница 36: ...35 of 39 Dated 17 09 19 V1 2 ESP HC DHW 11DC ESP HC DHW 17DC 6 Water pump water flow curves RS 15 7 0 RS 25 7 5...