5
COMPLETION & STORAGE
1. Switch off steam and vacuum pump switches, and unplug the unit.
2. Allow the unit to cool completely and then empty the unit and waste water collection tank of any remaining water. Never leave
water in the unit whilst being stored.
3. Once the unit has cooled, wind the cable around the base of the feet on the unit and then wind the hose around the leg clips.
Slot the steam plate into the side slots on the feet.
HOW TO ASSEMBLE THE SPARE VACUUM CUP
AND STEAM PLATE FILTER
Insert the vacuum seal (6) into the steam plate as shown.
Insert the foam pump filter (7) as shown.
1.1
1.2
1.3
1.4
1.5
2.1
2.2
2.3
2.4
1. If you are right handed, hold the steam plate in your left hand and place flat against the ceiling where you wish to commence
removing the Artex/paper.
2. Leave the plate on the ceiling for a maximum of 10 seconds. The length of time will depend on the type of covering you are
removing.
3. If you are left handed you may find it easier to operate with the other hand.
4. Move the steam plate to the section immediately next to where you have just been working and use a wallscraper to remove the
section that has just been steamed.
5. Empty the ceiling waste water tank when it starts to become full. It holds a total of 500ml of water and in 78 minutes should only
require emptying once if a full tank is used.
6. By working in this way you should be able to remove Artex/Paper continuously.
7. You may have to leave the plate on the ceiling for longer periods or re-steam if not completely removed.
8. Operate the steamer until steam is no longer produced (there is a safety cut out when water level gets too low), switch off the
vacuum and leave for a minimum of 2 minutes before refilling. Allow to cool completely before packing away.
5mm