CREATED ON: August 23, 2021
Dimension
Note: All Dimensions are in mm.
Front Panel
Rear View
Terminal Details
1, 2 : Source voltage
6 : +12V
7 : Output
8 : GND
8, 9 : Short for – NPN and LIMIT SWITCH
Open – PNP
12, 10 : RESET (short for atleast 250mS)
11, 10 : Short – HOLD
Open – RESTART
3 : NC
4 : NO
5 : C
NOTE:
Select PNP or NPN sensor/Limit switch before power ON.
Connect Limit switch between 7 & 8.
Wiring
* Though the standard relay output rating is 5A,
it is always necessary to use rated contactor to switch
ON/OFF the load as shown above.
This ensures healthyness of equipment in case of fault
short created on the power output lines.
Programming Instruction :
Timing Example:-
Counts = 99999
SENS = 100
Press “SELECT” once, display shows “SET” for 2 seconds and then
display shows previous set value with MSD flashing.
Press “ADVANCE” till display shows 9.
Press “SELECT” again; 2nd digit starts flashing.
Press “ADVANCE” till display shows 9.
Press “SELECT” again; 3rd digit starts flashing.
Press “ADVANCE” till display shows 9.
Press “SELECT” again; 4th digit starts flashing.
Press “ADVANCE” till display shows 9.
Press “SELECT” again; 5th digit starts flashing.
Press “ADVANCE” till display shows 9.
Press “SELECT” again; the set value is saved in memory and the
display shows “SEnS” for 2 seconds and then display shows
previous sensitivity value.
Press “ADVANCE” till the display shows 100.
Press “SELECT” display shows ‘00000’ to indicate counter is ready
for operation. Same procedure shall be followed for different
counts and sensitivity values.
Contact Rating
RLY 1C/O rated for 5Amps@250VAC/30VDC (NO) and
3Amps@250VAC/30VDC (NC)
Disposition
Once the product life is over, you may send back the
unit to EAPL for disposition.
Contact
Electronic Automation Private Limited
#20, KHB Industrial area
Yelahanka
Bangalore -64
Ph:+91-80-28567561/2,/42802345
Customer support :Ph:+91-80-42802323
Email :
www.eaplindia.com
OD RH YN 610002 REV 02/23-08-2021