41
set below
alarm output options as below.
1.Follow alarm output 2. Follow AC power fault output
3.Follow arm output 4, Follow disarm output
5, Follow Communication fault output 6. Password control output
Example: set PGM output port follow the password control output.
When follow the password control output. Press [5] button from the alarm control
panel for 3 seconds. Input the password, enable or disable the PGM port. Or can
operate it through the voice phone call and GSM message remote control.
6.8.5 delete system log
Press[*] for 3 seconds
6.8.6 restore to factory fault
Press[*] for 3 seconds
*
Enter password
0 1 2 3 4 5
#
8 #
4 #
Please select PGM output port follow event
1.Follow alarm output
2. Follow AC power fault output
3.Follow arm output
4, Follow disarm output 5, Follow
Communication fault output 6. Password control output,press
confirm key to save, press back key to exit.
5 #
*
Enter password
0 1 2 3 4 5
#
8 #
5 #
Please re-confirm to delete system
event,press confirm key to
save,press back key to exit.
#
*
Enter password
0 1 2 3 4 5
#
8 #
6 #
Please re-confirm to restore to
factory default,press confirm key to
save,press back key to exit.
#
Содержание ST-VGT
Страница 1: ...TCP IP GSM Home Alarm Control Panel Instruction Manual ST VGT ...
Страница 19: ...14 3 5 Alarm Procedure ...
Страница 57: ...52 7 6 Voice Phone Please refer to the manual 6 4 ...
Страница 63: ...58 7 12 System Reboot Including system reboot and restore to factory default setting 7 13 Alert Setting ...
Страница 65: ...60 7 16 Home Automation It can set 16CH appliance switch ...
Страница 70: ...65 8 4 Function Settings First enter into the function setting have to set the gesture password ...