 Choose  output  port  NC/NO  according  to  actual  needs,  then  connect  it  and  port 

COM to the certain lift control system input port. 

REMARK: 

If the lift control module is installed at the end of the vertical bus, it needs to set the match switch. Operation 

way: set the SW1 to be ON. 

If there are more than 1 lift control module in the system, it needs to set the order switch SW2. Operation way:   

Set both 1 and 2 on SW2 OFF: 1st to 16th floor. 

Set 1 OFF and 2 ON: 17th to 32th floor. 

Set 1 ON and 2 OFF: 33rd to 48th floor. 

Set both 1 and 2 ON: 49 to 64 floor.   

 

Indicator: 

The yellow lights on V-UP and V-DOWN ports: They 

are off at standby state.When there’s communication, 

they shall flicker. 

The green lights would be on at standby state. When they are flickering every 1 second, it means the 

communication on vertical bus is abnormal. When they are flickering 3 times every second, it indicates that 

the voltage on the vertical bus is too low(It can check the power load status when install the system, the green 

lights do not flicker at standby state, and will flicker quickly when there’s communication.). When the green 

lights flick every 3 seconds, it means that the communication is abnormal and the voltage is too low. 

 

Short press K1 button(on PCBA) to do communication self-checking, if it

’s normal, the yellow lights will flicker 

a few times.   

Long press K1 button(on PCBA) to do self-checking of lift control output: all reply will be active one by one, 

and call the lift from 1st to 16th floor.         

 

6. Installation                       

(1) Surface mounted 

Fix the lift control module with fixing screws and expansion bolts. 

 

 

 

     

Содержание NL01

Страница 1: ...k you for purchasing our products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The products are subject to change without prior notice ...

Страница 2: ...ex 1 Warning 1 2 The outlook and ports of the product 1 3 Features 错误 未定义书签 4 Package content 2 5 System wiring 2 6 Installation 3 1 Surface mounted 3 2 Guide rail mounted 3 7 Specification 4 Version V1 0 ...

Страница 3: ...product near a heat or humid place 4 It s forbidden for any unprofessional people to change the coding switch or the connection wires 2 The outlook and ports of the product 1 Vertical upward bus port 1 4 Lift control port for 9th to 16th floor 2 Vertical downward bus port 2 5 Coding switch 3 Lift control port for 1st to 8th floor 6 Reserve RS485 Port ...

Страница 4: ...or maintenance Relay output support all kinds of lift control system Signal isolation function can make the system work more stable 4 Package contents Lift control module User manual Desiccant 4 M4 30 fixing screws 4 Expansion bolt 5 System wiring 1 The connection way is same as vertical distributor it can be connected into vertical bus as below diagram see below bold cable The cable is standard C...

Страница 5: ...lights would be on at standby state When they are flickering every 1 second it means the communication on vertical bus is abnormal When they are flickering 3 times every second it indicates that the voltage on the vertical bus is too low It can check the power load status when install the system the green lights do not flicker at standby state and will flicker quickly when there s communication Wh...

Страница 6: ...7 Specifications NO Item Specification 1 Operation voltage DC18V 36V 2 Operation Currency 200mA max 30mA standby 3 Operation temperature 30 to 50 4 Operation humid 0 95 5 Lift control signal 16 channels relay output NO NC optional no screw needed 6 Extended lift control module quantity 4 Maximum support 64 floors 7 Communication mode CAN bus 8 Communication signal isolation mode Optoelectronic iso...

Отзывы: