Содержание Ultra II

Страница 1: ...uhavetwosignals ofequal size onewithgray andtheotherwithout thenthetarget with grayis the stronger signal This helps distinguish weedsfromtreesonthebottom orfish fromstructure GRAYLINE is adjustable Since GRAYLINE shows the differencebe tween strongand weaksignals adjusting thesensitivity mayrequirea 8 TFpuurnuth A ts A different GRAYLINE level also The levelchosenbythe UltraII at power on isusual...

Страница 2: ... acrossthe screen arethe exactsame echoes on both sidesofthescreen They re simply enlarged on the left side Thisfeaturetracksthebottom keeping itonthedisplayatalltimes whenthe automatic feature is on Onceyou vesetthe zoom asdesired press the CLEAR keyto erase the menus ZOOM MANUAL MODE Whenyoupress thezoom keywhile the unitis in the manual mode the screen shown below appears All of the menus onihi...

Страница 3: ... nextpagealso appear Turnthezoomfeatureon oroff bypressingthekeyadjacentto the OFF ON label chor Since theunitisnotmov ing fishsignalsare long drawn out lines on a normal chart display FASTRAKconverts thegraphtoaverticalbargraph that with practice makes a useful addition to fishingat a stationary location SELECTUNITS OFMEASURE TheUltraIIcandisplaythewater depth infeet fathoms ormeters surface wate...

Страница 4: ...ngthe High ASPsetting However ifyouare havingtrouble withnoise wesuggestthatyoutakestepstofindtheinterferencesource andfixit rather than continually usingthe unitwiththe highASPsetting 26 thenpresstheright arrow key SENSITIVITY Thesensitivitykeyonthe Ultra IIcontrols theabilityofthe unittopickup echoes A lowsensitivity levelexcludes much ofthebottominformation fish signals and othertargetinformati...

Страница 5: ... switch to the manual mode The letters Man ap pearintheupperleftcorner of thedisplay indicating the unit j113 9FTft Thisallowsyoutoviewallincomingechoesbeforetheyareprocessed by the ASPfeature TochangetheASPlevel presstheMENU keyfivetimes Thenpress the keynexttothe ADJUST LEVEL OFCHARTASP labeluntil thedesired level isobtained CLEARDISTANCELOG Ultra II Plus Only TheUltraIIPlus candisplaythelog dis...

Страница 6: ...lears placingthe newwindowintheupperleftcornerofthescreen lithe new windowtakes uphalfthescreen theunitwillplaceitontheleftsideofthe screen Continuewiththewindowselections untilthescreen isfilled Theunitwill stayinthewindowsmodeusingyournewcustomizedscreen Ifyoudon t wanttofillascreen and onlyuseone two orthreewindowsinagroup simplypressthekey adjacenttothe STOP label Thissavesthegroup and exitsth...

Страница 7: ... Adescription ofthescreenshowsinthe Selectthe letter of thegroup youwishtocustomizebypress ing the key adjacent to the group s label Ifthelabel isn t shown onthispage press the key adjacentto the MORE label Inthis example thekey nextto the GROUPA label was pressed The screen shown at the top of the next page appears 8 29 I FEET I 58 2 boxatthebottomofthescreen Nowpressthekeyadjacenttothe NEXT labe...

Страница 8: ...ejunctionofawarm and cool layerofwateris called athermocline Thedepth andthickness ofthethermoclinecanvarywiththeseasonortimeofday Indeeplakes theremaybetwoormoreatdifferentdepths Thermoclines areimportant tofishermenbecause theyareareaswhere fishare active Manytimes baitfishwillbeabovethethermocline whilelargergame fishwillsuspend in orjustbelowit TheUltra II candetect this invisiblelayerinthe wa...

Страница 9: ...anchangethedisplays ontheUltraII and UltraIt Plusbyusingthe windows feature Thisletsyoucustomize displays toyourown fishing or boating situations Thisfeaturealso gives you 7displayscreensonthe Ultra II and 15 on the Ultra It Plus 500 Thescreens available inthewindowsmode aredividedintotwoormore windowsperscreen Eachscreen ofwindows iscalleda group Group A asshownat thetopofthe nextpagehas the digi...

Страница 10: ...yis pressed thechartstopsscrolling Thisdoesn t affectthe digital display however ARROWKEYS Thesekeys are usedto make menu selections andto moveoblectson the screen ON TheONkeyturnsthe UltraIIon OFF Press and HOLDthe OffkeytoturntheUltraII off DISPLAY General Thelightsareturnedonforapproximately ten seconds whentheUltraII is firstturnedon Menus appear atthesametime To keepthe lights on pressthekeya...

Страница 11: ...orking orifyou need technical help pleaseusethe followingtroubleshootingsection beforecontacting thefactorycustomer servicedepartment Itmaysaveyouthe troubleof returning yourunit Unit won tturn on 1 Checkthepower cable s connection attheunit Alsocheckthewiring 2 Make certainthepowercableiswiredproperly The redwireconnects to the positive batteryterminal black to negative orground 3 Check the fuse ...

Страница 12: ...nittodisplay afish arch ithastobeabletoreceivethefish sechofromthetimeitenters the cone until it leaves Ifthe sensitivity is not high enough the unit displaysthefish onlywhen itis in thecenterofthe cone 3 Usethe Zoomfeature Itismuch easierto displayfish arches when zoomedin onasmallrangeofwaterthana large one Forexample you will havemuch betterluckseeing fish arches with a30 to 60foot range thana0...

Страница 13: ...m signal on the display Nowturnon each pieceofelectrical equipmenton the boat and viewtheeffectonthesonar sdisplay Forexample turnonthebilgepump andviewthesonardisplayfornoise Ifnonoiseispresent turnthepump off then turn on the VHF radio and transmit Keep doingthis until all electrical equipment hasbeen turnedon theireffectonthesonardisplay noted then turnedoff Ifyoufindnoiseinterference fromanele...

Страница 14: ...so getdigital boat speed surface watertemperature anddistancetravelled log displays Readthismanualandtakeitwithyouthefirstfewtimesyouuseyourunit It sagreatreference ifyou need it MOUNTING InstalltheUltraII inanyconvenient location provided thereisclearance behindthe unitwhen it istilted for the bestviewing angle Holes in the bracketbaseallowwoodscreworthrough boltmounting Youmayneed toplaceapieceo...

Страница 15: ...wnonthefollowing pages w ir FISH 36 6 U FTIUIDEPTH 48 1 GROUP B 37 UDI k I I I FEET I I F I 45 2 65 4 sIe I MPH I IMILESI 5 4 2 0 GROUP C DI4i I FEET I 51 1 r I JOLTS I 12 6 lou GROUP A GROUP D GROUP E GROUP F GROUP G PDF compression OCR web optimization with CVISION s PdfCompressor ...

Страница 16: ...R 23 DISPLAY ZOOM BAR 23 DISPLAY ZONEBAR 24 DIGITALSONAR 24 MENU PAGE4 24 FASTRAK 24 SELECTUNITSOFMEASURE 25 MENU PAGE5 26 ADJUSTCHARTSURFACE CLARITY 26 ADVANCED SIGNALPROCESSING ASP 26 CLEARDISTANCELOG 27 SIGNALINTERPRETATION 27 TRANSDUCERS ANDCONEANGLES 28 FISH ARCHES 28 WATERTEMPERATUREANDTHERMOCLINES 30 SURVEYINGALAKE 31 BAIT FISH 32 SONARTROUBLESHOOTING 33 Copyrighte 1992 EagleElectronics All...

Страница 17: ...PDF compression OCR web optimization with CVISION s PdfCompressor ...

Страница 18: ...Ultra II and Ultra II Plus INSTALLATION AND OPERATION INSTRUCTIONS LITHOIN U S A 988 0132 00RevA EAGI PDF compression OCR web optimization with CVISION s PdfCompressor ...

Отзывы:

Похожие инструкции для Ultra II