Eagle ECON Series Скачать руководство пользователя страница 18

Product Information

EAGLE offers a Limited Warranty (Parts and Labour) for the components that fail

due  to  defects  in  materials  or  workmanship.  Warranty  starts  from  the  date  of 

purchase up to 12 months . 

During the warranty period, should any repairs be necessary, the purchaser must 

inform its suppler or EAGLE Company. The company or its authorised Technician 

reserves the right to repair or replace the components at the purchaser's site or any 

of its workshops depending on the severity  of the problems at no additional cost. 

However, any freight involved in sending the faulty units or parts to the service 

center will be borne by the purchaser.

The warranty will cease to operate if  the equipment is not returned in the original 

packaging and with correct documentation for a claim to be processed. All claims 

are at the sole discretion of EAGLE company.

This warranty does not cover equipment where defects or poor performance is due 

to  misuse,  accidental  damage,  exposure  to  radioactive  or  corrosive  materials, 

negligence, faulty installation, unauthorized   modification or attempted repair or 

failure to observe  the requirements and recommendations as  given in this User 

Manual.

Repairs  carried  out  under  the  warranty  does  not  extend  the  warranty  period.

Components removed during the warranty repairs become the company property.

Warranty Information

Model No.
Serial No.
Invoice No.
Date of Purchase
Name, Address & Stamp of Dealer :

11

PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES

Survey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, 

Fax : + 91 - 20 - 30418126. Email : [email protected]

Содержание ECON Series

Страница 1: ...Digital Weighing Scale ECON Series USER MANUAL...

Страница 2: ...30418100 110 Fax 91 20 30418126 Email sales egkantawalla com INDEX 1 Gratitude 2 Unpacking 3 Installation Procedure 2 Technical Data of Scale 3 Connections 4 Key Operation 5 Scale Functions 6 User Pa...

Страница 3: ...nversion Weight Accumulation Function up to 999999 Selectable display speed Auto Tare Peak Hold Auto Sleep Zero Locking counts and Stable time setting These Scales also feature a variety of other func...

Страница 4: ...Red Pin 2 Supply Black Pin 3 Signal Green Pin 4 Signal White Pin 5 Shield RS 232 Cable Wiring Db9 Pin Female Connector Scale End DB9 Pin Female Connector Scale End GND Pin 5 Pin 5 GND Tx Pin 3 Pin 2...

Страница 5: ...can count the similar items on the scale The scale have 6 fixed sample sizes they are 10 20 50 100 200 and 500 pieces When the Func Key is pressed the display alternates between the following 1 S 0 th...

Страница 6: ...r of samples on the scale as 10 To Recall Previous Counting Mode 1 Press Func key the display will show S 0 2 Press Func key again to change the option and select S Cnt 3 Press M key for the confirmat...

Страница 7: ...ated weight three times and then back to weighing mode To clear the accumulated weight Press M key in zero mode sale display will show Add xxx for 1 sec and then flashes accumulated weight During the...

Страница 8: ...tr 01 tr 02 tr 13 b rAt b 1200 b 2400 b 4800 b 9600 OUt N d OUt OUt G OUt t TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO M M M M Chapter 8 User Parameter Setting Mod...

Страница 9: ...ro function Peak Hold Function Auto Sleep Time Zero Lock Counts Stable Time Auto Tare function Stable Time Pn Zro Zro y Zro n P HLd HLd n HLd y A SLP SLP 00 to 99 Zr Loc Loc 00 to 99 Stb t Stb 2 Stb 1...

Страница 10: ...ssing FUNC key it will back to display Speed Selection If without selection escaped out then scale will work on previously set speed 2 RS 232 Data Format tr 232 The scale have 13 different Data format...

Страница 11: ...Data Format d Scale always shows previously set Data Format Using TARE ZERO keys select from tr 01 to tr 13 e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing...

Страница 12: ...e immediately removed only if scale goes in negative value e g Acontainer is kept on the scale and is automaticallyTARE the weight once now material is filled in the container i e scale is showing wei...

Страница 13: ...ly set Power ON Zero Using TARE ZERO keys select trE y or trE n e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing FUNC key it should back to Power ON Zero If...

Страница 14: ...o SleepTime c Press M key to selectAutoTare d Scale always shows previously set Auto Sleep Time Using TARE for DECREASE ZERO for INCREASE and N G key for SHIFT can change the Sleep time e Press M key...

Страница 15: ...conversion factor maximum value allowed is 1 000 To setAuto SleepTime a Enter in to User Parameter Setting Mode b using TARE ZERO keys select Set Liter Factor c Press M key to enter Liter Factor d Sc...

Страница 16: ...eys select from Stb 1 to Stb 3 e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing FUNC key scale will go back to Stable Time If without selection escaped out...

Страница 17: ...solvent e g benzene nitro class oil to clean the housing 5 Liquid or electricity conducting particles should not be poured into the scale 6 You should cut off power supply of scale and relevant devic...

Страница 18: ...nt is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of EAGLE company This warranty does not cover equipment wh...

Страница 19: ...le Top Scales Platform Scales Crane Scales Pallet Scale LifeStyle Scales Hanging Scales 12 PROVIDER OF LIFE STYLE INDUSTRIAL SCALES Survey No 28 1 Damodar Nagar Kharadi Pune 411014 Tel 91 20 30418100...

Отзывы: