SW4 - ON = Only last minute warning tone will sound.
OFF = All progress tones will sound.
This enables the installer to disable all the progress tones (one per minute) except the last minute
shut down warning tone. This is beneficial for use in demo kits.
SW5 - ON = Enables the CENTRAL STATION DETECTION feature.
OFF = Disables the CENTRAL STATION DETECTION feature. This is recommended when the subscriber has
call waiting which cannot be disabled.
SW 6 - ON = Enables the AUTO TRIGGER FUNCTION.
OFF = Disables the AUTO TRIGGER FUNCTION. This is recommended when using a hard trigger from a control
panel.
SUMMARY OF SWITCH SETTINGS
SWITCH
1
2
3
ON
FACTORY TEST
IMMEDIATE TURN ON
POSITIVE EDGE
OFF
NORMAL
SET UP RING DETECT WINDOW
N E G A T I V E E D G E
ALL TONES ACTIVE LAST MINUTE TONE ONLY
5 CENTRAL STATION DETECT D I S A B L E D
AUTO TRIP ON
AUTO TRIP OFF
3.3 WIRING AND PLACEMENT.
WIRE CONNECTION
BROWN
RED
ORANGE
Negative supply input (GROUND)
Positive supply input
(+
12 VDC)
Trigger input (see options)
YELLOW Alarm active from control panel (Ground on alarm) see manual.
BLUE External siren input (-) (set P5 & P6, Section 6.1)
GRAY
Common relay contact.
BLACK Normally open relay contact. Closed when audio active.
4
P/N 1195 1 1 Rev. 2