background image

SW4 -   ON = Only last minute warning tone will sound.

OFF = All progress tones will sound.

This enables the installer to disable all the progress tones (one per minute) except the last minute
shut down warning tone. This is beneficial for use in demo kits.

SW5 - ON = Enables the CENTRAL STATION DETECTION feature.

OFF = Disables the CENTRAL STATION DETECTION feature. This is recommended when the subscriber has

call waiting which cannot be disabled.

SW 6 - ON = Enables the AUTO TRIGGER FUNCTION.

OFF = Disables the AUTO TRIGGER FUNCTION. This is recommended when using a hard trigger from a control

panel.

SUMMARY OF SWITCH SETTINGS

SWITCH

1

2

3

ON

FACTORY TEST

 

IMMEDIATE TURN ON

POSITIVE EDGE 

 

 

  

OFF

 

 

NORMAL

SET UP RING DETECT WINDOW

 

N E G A T I V E   E D G E

ALL TONES ACTIVE LAST MINUTE TONE ONLY

     

   

5 CENTRAL STATION DETECT        D I S A B L E D

   

          

 

   

           

              

AUTO TRIP ON

 

AUTO TRIP OFF

3.3 WIRING AND PLACEMENT.

WIRE CONNECTION

BROWN

RED

ORANGE

   

      

Negative supply input (GROUND)

   

         

                

        

Positive supply input 

(+

 12 VDC)

          

 

                

   

Trigger input (see options)  

       

      

  

 

 

    

   

      

    

   

YELLOW Alarm active from control panel (Ground on alarm) see manual.

BLUE External siren input (-) (set P5 & P6, Section 6.1)

GRAY

Common relay contact.

BLACK Normally open relay contact. Closed when audio active.

P/N 1195 1 1 Rev. 2

Содержание 1225

Страница 1: ...EAGLEE Ii E INC MODEL 1225 TWO WAY AUDIO SYSTEM WITH REMOTE DIAL UP AND AUTO DETECT INSTALLATION INSTRUCTIONS...

Страница 2: ...r when communicating with the central station CALL BACK A procedure when the central station calls the premises after an alarm activation to initiate two way communications This can be used with or wi...

Страница 3: ...rs SW2 ON Activate immediately with the trigger input Line hold mode OFF Set up the ring detector to answer after one ring When SW2 is in the ON position the system will activate immediately with the...

Страница 4: ...TRIGGER FUNCTION This is recommended when using a hard trigger from a control panel SUMMARY OF SWITCH SETTINGS I I SWITCH 1 2 3 ON FACTORY TEST IMMEDIATE TURN ON POSITIVE EDGE OFF NORMAL SET UP RING...

Страница 5: ...e with GREEN positive input Connect alarm output here positive voltage active This activates the Model 1225 s internal siren driver Note do not use with YELLOW negative input External siren driver inp...

Страница 6: ...FROM PANEL SEE MANUAL BLUE ALARM OUTPUT FROM PANEL SEE MANUAL ALARM OUTPUT FROM PANEL SEE MANUAL TRIGGER INPUT SEE MANUAL I2 VDC FROM PANEL GND FROM PANEL EIII r L me _ _ tt IL SlCN4L WL __CNl 1463 4...

Страница 7: ...with the completion of the communicator s alarm report kiss off from the Central Station When the two way audio module is activated in this mode the operator if listening at that time will hear a two...

Страница 8: ...two way During two way the module will generate a beep once every minute Upon the fourth and final minute of two way the module will generate a two tone beep bop warning the central station that there...

Страница 9: ...itch to the high gain Listen only mode in the presence of loud background noise as that will only make it worse As with allelectronic devices electrostatic discharges can damage the components Handle...

Страница 10: ...at the products of its manufacture shall be free from defects in materials or workmanship to one Year from the date of invoice if such goods have been properly installed are subject to normal proper u...

Отзывы: