background image

 

 

 

 
 

 

  The  original  address  code  set-up  before  the  products  leave  the  factory: 

patterns and colors streamline, X,Y axis is the positive direction 

●  

Use the XLR-XLR cable from the signal output port of the consol to connect the signal input port of 

the  first  light,  connect  the  signal  output  port  of  the  first  light  with  the  signal  input  port  of  the  second 

light, and so on, until all lights are connected. Then connect the terminal plug with the signal output port 

of the last light. (Figure Appendix 1) 

 

Warning: Please remember the signal output of the last light should be connected with the terminal plug. 

This plug add a resistance around 120

Ω

  between 2nd and 3rd pin of CANON plug. Use this plug could 

effectively avoid the signal reflection created during DMX512 signal transmission. 

 

1200 Moving Head Light uses 3 core XLR outlet(plug). A transfer line from 5 core to 3 core will be 

needed if the controller you use is 5 core outlet (plug). (Please refer to Appendix 2) 

 

HMI 1200W lamp is discharge lamp, it is fully illuminated about 5-10 minutes after power is on. In 

the meantime, please restart about 10 minutes after power is off. 

 

  When  power  is  on,  the  equipment  will  undertake  self-examination,  and  can  undertake  operation 

after the self-examination is finished. 

 

Please don’t shake the equipment during operation. 

 

Please do not use the light continuously for over 8 hours. 

  Control Channel 

1200Moving  Head Light adopts international standard DMX512 signal.  There are  10  control channels 

and the detailed information of control is as follow:   

 
● Table of 18 control channels 

Channel 

0 – 255   

Control content   

Strobe 

0 – 255 

Shutter open/strobe slo

w~fast 10-10times/second

 

Vector mode   

0 – 255 

….. 

PAN 

0 – 255 

0 – 255,    pan 0-540

0

 

 

scan 

Tilt 

0 - 255 

0 – 255,    tilt 0-270

0

    scan 

X, Y speed adjustment 

0 – 255 

0 – 255 adjust speed from slow to fast 

Color Wheel A 

0 - 255 

0 – 255,    tilt 0-270

0

    scan 

Color Wheel B 

0 – 255 

 

Содержание 1000

Страница 1: ...SF SH04 Spot 1200W 220V 50 60HZ 18CH Moving Head Light USER MANUAL ...

Страница 2: ...ction It combines mechanism electron and optics and adopted international standard DMX 512 signal Technology Parameter Voltage AC220V 240V Frequency 50 60HZ Power 1500W HMI1200 lamp Channel 18channels Color Temperature 7000K Applied modern ABS engineer plastic housing Digital display can be reversed 180 degree suitable for different installation 16Bit super smooth scan pan 540 tilt 270 8Bit or16Bi...

Страница 3: ...nd maintenance persons must get familiar with the light performance before operation so that to avoid damage to the machine Please check if there is any damage during transportation before first usage Before changing the bulb please make sure the electric power is cut off and the lamp is cooled off Bulb temperature can reach above 200 degree Push the maintenance cover open the small bulb lid encas...

Страница 4: ...fer line from 5 core to 3 core will be needed if the controller you use is 5 core outlet plug Please refer to Appendix 2 HMI 1200W lamp is discharge lamp it is fully illuminated about 5 10 minutes after power is on In the meantime please restart about 10 minutes after power is off When power is on the equipment will undertake self examination and can undertake operation after the self examination ...

Страница 5: ... core and 5 core XLR control outlet plug 3 3 3 5 3 5 3 core plug 3 core plug 5 core plug 3 core pl ug 5 corepl ug 3 core pl ug DMX512 signal circuit Pin 1 screen Pin 2 signal Pin 3 signal The Instruction Manual for Computer Lightings The menu of control display boards is designed for various types of computer lights equipped with multiple functions of control mode and controlled easily For some sp...

Страница 6: ...TER to enter 1 nod 1 testing mode 1 Press UP or DOWN to select other modes press ENTER to enter showing RUN testing work If you need to exit please press ESC 2 nAst mainframe controlling This function allows you to test directly which don t require mainframe to send DMX synchronous signal to deputy plane Press UP or DOWN to select other modes press ENTER to enter appear ON as mainframe sending out...

Страница 7: ...ou to reverse in vertical Press ENTER to enter use UP or DOWN if you need to reverse please select ON if you don t need to reverse please select OFF press ENTER to save and exit press ESC to exit directly 七 rset device replacement This function allows you to restart up device to come back to original standard setting Press ENTER to confirm Esc Down Up Enter ...

Отзывы: