background image

05

Science Behind The Technology

EXP Technology uses a 

corona discharge 

system to generate 

Oxygen ions O

2

+

 and O

2

-

 

at a high density.

These O

2

+

 and O

2

-

 ions 

have high chemical 

activity and when 

reacting with water 

(H2O) molecules in the 

air, hydroperoxide H

2

O

2

 

is formed.

Once airborne, these 

hydroperoxides (H

2

O

2

then cluster around 

harmful pollutants.

A chemical reaction 

occurs and the 

hydroperoxides (H

2

O

2

break down the protein 

structure of the 

pollutants, rendering 

them harmless.

Technology Overview

Содержание EXP D5 Series

Страница 1: ...USER S MANUAL EXP D5 SERIES D5i M...

Страница 2: ...and safety Our friendly customer service team is available for any questions or concerns please do not hesitate to contact us Our goal is to provide the highest quality indoor air across the globe We...

Страница 3: ...age 3 Product Introduction Page 4 Technology Overview Page 5 Testing Data Page 6 Installation Page 7 Operation Troubleshooting Page 8 Technical Specifications Page 9 Device Dimensions Page 10 Warranty...

Страница 4: ...e that purify and freshen indoor air by nuetralizing the harmful pollutants The D5i M is designed for installation in HVAC systems for commercial and residential applications This compact easy to inst...

Страница 5: ...ions have high chemical activity and when reacting with water H2O molecules in the air hydroperoxide H2 O2 is formed Once airborne these hydroperoxides H2 O2 then cluster around harmful pollutants A c...

Страница 6: ...aphylococcus Aureus MRSA EMSL Analytical USA 99 Fungus Aspergillus Niger EMSL Analytical USA 97 Dichobotrys Abundans Prof Joe F Boatman USA 90 Penicillium Prof Joe F Boatman USA 95 Mold Cladosporium C...

Страница 7: ...wo recessed needlepoint electrodes simultaneously 4 For best results place unit in a location where needlepoints will be exposed to maximum airflow If magnetically mounting directly on the fan housing...

Страница 8: ...d only when the supply fan is running Therefore to achieve improved air quality interlock the D5i M unit to run when the supply fan is powered Troubleshooting IF THE UNIT IS NOT WORKING CHECK IN THE F...

Страница 9: ...otection 500mA Operation Environment Temp 14 F 158 F Hum 70 Storage Environment Temp 14 F 158 F Hum 85 Ozone 0 005 ppm CFM 1 000 to 2 400 Life Cycle 5 7 years depending on environmental conditions Pow...

Страница 10: ...Device Dimensions 10 2 2 Power Supply Indicator LED Recessed Needlepoints 4 7 8...

Страница 11: ...the product 4 Has been damaged after leaving EXP s facility 5 Has been serviced by unauthorized personnel or if parts in the system were found or exchanged which were not original parts from EXP 6 If...

Страница 12: ...EXP D5 SERIES D5i M Eagle X Pro LLC Headquarters Address 5415 Cameron Street Suite 121 Las Vegas Nevada 89118 Phone 833 324 5397 Email office eaglexpro com...

Отзывы: