Eagle Pro EL Series Скачать руководство пользователя страница 6

6

Problem

Cylinder will not extend
or fully extend

1.Pump release valve open
2.Couplers not fully tightened
3.Oil level in pump reservoir is low
4.Pump or valve malfunctioning
5.Overload for cylinder
6.Cylinder piston rod binding

1.Fully tighten pump release valve
2.Fully tighten couplers
3.Fill oil in pump
4.Repair or use another pump and valve
5.Change another cylinder with

appropriate capacity

6.Check for dirt or leaks, change the

damage parts

Cause

Solution

Cylinder can not
maintain pressure

1.Leaky connection
2.Cylinder seals leaking
3.Release valve not fully closed
4.Pump or valve malfunctioning

1.Clean and reseal thread, tighten connection
2. Replace worn seals. Clean inside cylinder

and use clean hydraulic oil

3. Fully tightening the release valve
4. Repair, or use another pump and valve

Cylinder extends
slower than normal

1. Leaky connection
2. Coupler not fully tightened
3. Pump malfunctioning

1.Clean and reseal thread, tighten

connection

2. Fully tighten couplers
3. Repair or use another pump and

valve

Cylinder extend in dithering

1. Air in system
2. Cylinder piston rod binding

1. Bleeding air in the system
3. Check for dirt or leaks. Check for bent,

misaligned and worn parts

Cylinder leaks hydraulic oil

1. Leaky connection
2. Worn or damaged seals
3. Cylinder damage

1.Clean and reseal thread, tighten

connection

2.Replace worn seals, clean inside cylinder

and use clean hydraulic oil

3. Use new cylinder of contact with your

nearest Authorized EAGLE PRO

Hydraulic Service Center.

Cylinder will not retract or
Retracts slower than normal

1. Pump release valve closed
2. Couplers are not fully tightened
3. Pump reservoir is full
4. Hose is blocked
5.EL cylinders are load return
6. Cylinder damaged

1. 0pen release valve
2.Tightening the couplers
3. Drain hydraulic oil to correct level
4. Clean or change hose
5. Retract cylinder by load
6.Use new cylinder or contact your
nearest Authorized EAGLEPRO
Hydraulic Service Center

07

TROUBLE-SHOOTING

WARNING:

EAGLE PRO Cylinders should be repaired only by a qualified

operator or authorized EAGLE PRO Service Center. Repair cylinders without
special tools and knowledge may result in personal injury. Please release

pressure and disconnect hose(s) before making repair.

EAGLE PRO INDUSTRIES, INC.

Form No. E01104

Rev. A Date: 06.10.2009