DAILY MAINTENANCE
1. Always keep the machine clean inside and out.
2. Pour 2 gallons of clean hot water in the solution tank. Turn the pump on and flush the entire
system through the wand nozzles for about a minute to prevent alkaline build-up.
3. Remove dirt and lint build-up inside the filter screen in the recovery tank. Lint should be
cleaned off so that air flow is not impeded.
4. Check the solution tank strainer in the solution tank. If lint has accumulated in the screen,
remove and rinse it in clear running water.
PERIODIC MAINTENANCE
All Eagle Power machines are engineered and built to require a minimum of maintenance. But like any
machine, it does require some care to keep it in optimum working condition. Careful attention to these
maintenance instructions will give you maximum operating performance and will increase the life
expectancy of your machine.
Solution Lines and Fittings. Flush the machine at least once a month with a solution of 1 part
water with 3 parts white vinegar in order to neutralize the alkaline residue left by the cleaning
solution.
Quick connect coupler. Spray with WD-40 or equivalent lubricant to prevent coupler from sticking.
Drain Valve. Apply light oil on gate seals. If machine has to be stored, leave the gate valve open.
Solution pump. The same above procedure used on solution line and fittings applies to the pump.