background image

3

MOUNTING LOCATIONS

CAUTION:

If a heat lamp is to be installed over a steam table, please see below for Eagle Group’s recommended installation heights. 

NOTE: The control switch box should be located and/or labeled so that it is clear to the operator which control switch box

operates its corresponding heat lamp.

WARNING - FIRE HAZARD

To avoid personal injury or damage to the unit, do not use the top surface of the heat lamp as a storage surface, 

as the heat lamp is not a load-bearing component. 

WARNING

The specified safe distance must be maintained between the heat lamp and any wall or countertop surfaces that are wooden or

combustible. If the safe distance is not maintained, discoloration or combustion can occur, causing personal injury or damage to

countertop, wall and heat lamp. If proper distances are maintained, all foods shall be kept at their ideal serving temperatures

without over-cooking. 

OPERATING MANUAL AND INSTRUCTIONS

WARNING

Standard Wattage Heat Lamps

There must be 10˝ minimum distance between the bottom of the heat lamp and the top of the combustible work surface and no less

than 8˝ between the bottom of the lamp and the top of a non-combustible work surface. There must be a 10˝ minimum distance

between the bottom of the heat lamp and the top surface of a steam table or heat-generating surface. There must also be a 1˝ clearance

from top of heat lamp. 

High Wattage Heat Lamps

There must be 16˝ minimum distance between the bottom of the heat lamp and the top of the combustible work surface and no less

than 8˝ between the bottom of the lamp and the top of a non-combustible work surface. There must be a 16˝ minimum distance

between the bottom of the heat lamp and the top surface of a steam table or heat-generating surface. There must also be a 1˝ clearance

from top of heat lamp.

Maintain a 7˝ minimum distance from rear and side walls that are considered combustible for both standard and high watt units. 

Содержание RedHots RHHL Series

Страница 1: ...tly GENERAL NOTES Eagle s RedHots Heat Lamps help keep your foods at their optimum serving temperatures while maintaining a high level of quality These heat lamps focus their heat over the entire area and provide even heat distribution to eliminate hot spots Eagle s RedHots Heat Lamps can be purchased in standard watt or high watt units with or without lights Heat lamp lengths range from 18 long t...

Страница 2: ...o be wired to cord plug ELECTRICAL REQUIREMENTS Optional Control Switch Box Connection When ordering a heat lamp with a remote the main unit does not contain any switches Following UL NEC and local codes install a copper supply wire temperature rated no lower than 90C to the control box Eagle Group supplies a 7 8 and 1 1 8 knockout on the sides of the aluminum housing and 6 long 12 gauge pigtails ...

Страница 3: ...ing temperatures without over cooking OPERATING MANUAL AND INSTRUCTIONS WARNING Standard Wattage Heat Lamps There must be 10 minimum distance between the bottom of the heat lamp and the top of the combustible work surface and no less than 8 between the bottom of the lamp and the top of a non combustible work surface There must be a 10 minimum distance between the bottom of the heat lamp and the to...

Страница 4: ...tab WARNING Chain must be 8 trade size and securely fastened or unit could come loose and possibly cause personal injury or damage to the unit Y shape chain connection part 358372 ordered per foot chain mounted heat lamp end view shelf bracket part 355148 8 32 screws 1 4 20 screws not included heat lamp UNDER SHELF MOUNT When mounting the heat lamp under a shelf maintain a 1 offset from the bottom...

Страница 5: ... Eagle Group Part Number 355148 for one bracket two brackets required Chain for Chain Mounted Units Eagle Group Part Number 358372 ordered per foot SAFETY PRECAUTIONS Only use mounting methods and materials described and suggested by Eagle Group to prevent personal injury or damage to the heat lamp and its components Be sure that all specified clearances have been maintained for safe operation and...

Страница 6: ...6 RedHots Heat Lamps WIRING DIAGRAMS ...

Страница 7: ...7 RedHots Heat Lamps WIRING DIAGRAMS ...

Страница 8: ...actory for assistance this warranty does not cover any cost associated with maintenance misuse abuse improper installation pilot light adjustments pilot outage improper ventilation adjustments alteration calibration wrong voltage wrong gas voltage or gas conversions resetting of circuit breakers or safety controls overtime charges travel charges on portable equipment mileage in excess of 100 miles...