![EA3GCY ILER-40MK2 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/ea3gcy/iler-40mk2/iler-40mk2_assembly-manual_3250262021.webp)
ILER-40 MK2 SSB QRP Transceiver Kit
Page 21
IMPORTANT: Wind the toroid exactly as shown in the pictures. You must pay attention to number of
turns as well as to the direction of the winding.
Toroidal transformer T6
T6 is an impedance matching transformer with a bifilar winding. A FT37-43 is used (black toroid with
9.5mm/0.375in OD). It has 8+8 turns.
- Cut a 31-32cm (12in) long piece of 0.5mm diameter enameled wire.
- Bend the wire in half.
- Twist it so that there are about two twists per cm.
16cm (32 cm bent in half)