ILER-20 MK2 SSB QRP Transceiver Kit
Page 16
Capacitors
There are ceramic, polystyrene (styroflex) and electrolytic capacitors. They all have their value printed on
the body. Refer to the “identified” column in the parts list.
When you mount them, make sure to leave the leads as short as possible.
C79, C80 and C81 are polystyrene capacitors; these are axial capacitors, but they must be placed in a
vertical position.
The values which are in decade increments can be easily confused, such as 100n and 10n, so be sure
to verify the numbers of their value before soldering them in place!
The electrolytic capacitors must be placed with the correct orientation: the LONG LEAD goes in the hole
labeled “+” and the SHORT LEAD is "-", indicated by a band containing "-" signs on the side of the
capacitor.
CV1 is a trimmer capacitor which is black in color. It does not have printed numbers. Place it with the
rounded edge closest to the relay.
CV2 + CV3 are the same capacitor; it is a dual-section “Polyvaricon” variable tuning capacitor. DO NOT
INSTALL IT yet.
Radial Inductors VK200
L8 and L10 are broadband ferrite RF chokes; they are mounted in a vertical position.
Separate them approximately 0.5 - 1mm above the board to prevent the windings from touching any part
of the printed circuit.