6.3.9
Save & Restore Settings
The settings (or Main configuration) of the Camera can be saved in 4 different User banks and one
Integrator bank. This setting includes also the FFC and LUT enable
This function is available in the Save & Restore Settings section :
•
Load settings from Bank
:
Allows to restore the Camera settings.
Read function : “
r rcfg
” : Get the current Tap Bank in use
Write function : “
w rcfg <val>
” : Load settings from bank <val> (0: Factory , 1 to 4 for Users, 5 for
Integrator)
Save settings to Bank
:
Allows to save the Camera settings in User or Integrator Bank
Write function : “
w scfg
<val>
” : Save the current settings in the User bank <val> (1 to 4 for User, 5
for Integrator)
The integrator bank (User Set5) can be written only if the Camera is set in integrator mode
(Privilege level = 1). This integrator bank can be used as a « Factory default » by a system
integrator.
Configuration Bank Usage
At the power up :
Last User Bank used is loaded in RAM
“Integrator” Bank (5) can be locked by switching the Camera in “User” mode (cf : Privilege feature).
Then it can’t be saved any more without switching back the Camera in “Integrator” Mode.
Ram Memory
Save
Load
Factory
Integrator
User1
User2
User3
User4
User
Load
Save