![E2S WP6-BG Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/e2s/wp6-bg/wp6-bg_instruction-manual_3493715003.webp)
Y
WIRE LINK
N/C
N/O
COM
8
7
M/S 1
6
5
4
3
2
1
R
B
Y
N/C
N/O
COM
EOL
SER
8
7
M/S 1
6
5
4
3
2
1
R
B
Y
N/C
N/O
COM
EOL
SER
8
7
M/S 1
6
5
4
3
2
1
R
B
Y
5
N/C
N/O
COM
EOL
SER
8
7
M/S 1
6
4
3
2
1
R
B
Y
N/C
N/O
COM
EOL
SER
8
7
M/S 1
6
5
4
3
2
1
R
B
-
N/C
-
N/C
-
-
N/O
COM
N/O
COM
DIODE
ZENER DIODE
POSITIVE (+) COMMON
(IF DIODES SUPPLIED & CONFIGURED BY E2S)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
+
+
+ +
-
-
-
N/O
-
-
-
-
+
+
+ +
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
POSITIVE (+) COMMON
(IF DIODES SUPPLIED & CONFIGURED BY E2S)
ZENER DIODE
DIODE
N/O
N/C
-
COM
-
N/C
COM
N/O - Normally Open
Key:
COM - Common
N/C - Normally Closed
(Contacts closed in unoperated state)
(Contacts open in unoperated state)
5
EOL
SER
IE
S
8
7
4
5
EOL
SER
IE
S
8
7
4
Y
8
N/C
N/O
WIRE LINK
7
COM
M/S 1
6
5
4
3
2
1
R
B
WP6 CALL POINTS
R.N.POTTS
2S
07-02-20
3
1
NTS
D.A.H - 07-02-2020
WWW.E2S.COM
C
LONDON W3 7QH
ACTON
MANSELL ROAD
IMPRESS HOUSE
EUROPEAN SAFETY SYSTEMS LTD
WP6-BG WEATHERPROOF BREAK GLASS
MANUAL CALL POINT WIRING SCHEMATIC
IF IN DOUBT, ASK -
AS PER LATEST DATE OF ISSUE SHOWN ABOVE
EUROPEAN SAFETY SYSTEMS LTD.
WRITTEN CONSENT.
MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR
ANGULAR DIMENSIONAL TOLS
STANDARDS
MOD No.
REASON - INITIAL - DATE
ISSUE
DATE
APPROVED
CHECKED
DATE
DATE
DRAWN
WEIGHT (Kg)
SURFACE FINISH
MATERIAL
ALTERNATIVE MATERIAL
SHEET
SCALE
TITLE
A3
LINEAR DIMENSIONAL TOLS
DO NOT SCALE
ALL DIMENSIONS IN MM
DRAWING NUMBER
A
B
C
D
E
F
G
10
9
G
F
E
7
8
6
5
D
C
1
3
4
2
A
B
D233-06-001
07-02-20
D.HOWGILL
R.N.POTTS
07-02-20
OF
THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE
MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND
IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY
SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY
BE DISCLOSED, LOANED, COPIED OR USED FOR
DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
INTRODUCTION
1
warning signals
E2S PART NO.
WP6-BG
DESCRIPTION
WP6-BG WEATHERPROOF BREAK GLASS MANUAL CALL POINT
1A - Circuit shown in Unoperated condition
(Glass Intact / Standby Condition)
Terminals (4,5) & (7,8) open
Terminals (4,5) & (6) closed
NOTE: Series / EOL devices can be fitted either by
customer or pre-installed by E2S at point of order.
polarity across devices must be observed
(Resistor polarity unimportant)
When fitting diodes or zener diodes,
Standard Unit as supplied by E2S
1B - Circuit shown in Operated condition
(Glass Broken / Button pushed in)
Standard Unit
Showing alternative configuration of optional Series / EOL Devices
Terminals (4,5) & (6) open
SWITCH TYPE: [S] - Single Microswitch
Terminals (4,5) & (7,8) closed
Wiring option shown with EOL &
series devices acting in parallel
Standard Unit
Showing positions of optional Series / EOL Devices
Wiring option shown with EOL &
series devices acting in series
Terminals (4,5) & (6) closed
Terminals (4,5) & (7,8) open
(Glass Intact / Standby Condition)
2A - Circuit shown in Unoperated condition
Terminals (4,5) & (6) open
Terminals (4,5) & (7,8) closed
(Glass Broken / Button pushed in)
2B - Circuit shown in Operated condition
Terminals (4,5) & (6) open
Terminals (4,5) & (7,8) closed
(Glass Broken / Button pushed in)
3B - Circuit shown in Operated condition
Terminals (4,5) & (6) closed
Terminals (4,5) & (7,8) open
(Glass Intact / Standby Condition)
(Resistor polarity unimportant)
WP6-BG[S]
polarity across devices must be observed
Without Series / EOL Devices
3A - Circuit shown in Unoperated condition
When fitting diodes or zener diodes,
NOTE: Series / EOL devices can be fitted either by
customer or pre-installed by E2S at point of order.
DATA REFERENCE
2-41-020