E2S STExB2X05DC012 Скачать руководство пользователя страница 4

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D199-00-201-IS

 

Issue 4

 

07-10-21

 

 

Sheet 4 of 7

 

 

5)  Special Conditions for Safe Use 

 
Repair of the flame path / flameproof joints is not permitted. 

 

Figure 1: Flame Path. 

 

The  metallic  enclosure has a non-conductive coating.  These 
may generate an ignition-capable level of electrostatic charges 
under certain extreme conditions. The user should ensure that 
the  equipment  is  not  installed  in  a  location  where  it  may  be 
subjected to external conditions that might cause a build-up of 
electrostatic charges on non-conducting surfaces. 
 

6)  Product Mounting and Access 

 

6.1.  Location and Mounting 

 

The location of the beacons should be made with due regard 
to the area over which the warning signal must be visible. They 
should only be fixed to services that can carry the weight of the 
unit. 
 
STExB2X21 models shall not be mounted with the lamp down. 
 
The STEx beacons should be securely bolted to a flat surface 
using 9.0mm diameter bolt holes in the base of the unit. See 
figure 2. 

 

Figure 2: Fixing Location for B2 Beacon.

 

 

6.2.  Access to the Flameproof Enclosure 

 

 

Warning 

 

Hot surfaces. External 

surfaces and internal components 
may be hot after operation, take 
care when handling the equipment. 

 

In order to connect the electrical supply cables to the beacon 
it is necessary to remove the flameproof cover to gain access 
to  the  flameproof  chamber.  To  access  the  Ex  d  chamber, 
loosen  the  M4  grub  screw  on  the  beacon  cover.  Open  the 
enclosure by turning the beacon cover counterclockwise and 
remove  the  cover,  taking  extreme  care  not  to  damage  the 
flameproof threads in the process (See figure 3).   
 

 

Figure 3: Accessing the Explosion Proof Enclosure.

 

 
On completion of the installation, the flameproof threaded joint 
should be inspected to ensure that they are clean and that they 
have not been damaged during installation. 
 
Repair of the flame path / flameproof joints is not permitted.  
 
Ensure 

that the ‘O’ ring seal is in place.

 

 
When  fitting  the  flameproof  cover  ensure  the  thread  is 
engaged correctly. Fully tighten the cover all the way, ensure 
no  gap  is visible between  the  cover and  base  of  the  beacon 
enclosure. Tighten the M4 grub screw. 
 

7)  Installation Requirements 

 

7.1.  Installation Standards Compliance 

 

 

Warning 

 High voltage may be 

present, risk of electric shock. 
DO NOT open when energised, 
disconnect power before opening. 

 
The  beacon  must  only  be  installed  by  suitably  qualified 
personnel in accordance with the latest issues of the relevant 
standards. 
 
ATEX / IECEx installation standards: 

 

EN60079-14  /  IEC60079-14:  Explosive  atmospheres  -  
Electrical installations design, selection and erection.

 

 

EN60079-10-1 / IEC60079-10-1: Explosive atmospheres - 
Classification of areas. Explosive gas atmospheres.

 

 

EN60079-10-2 / IEC60079-10-2: Explosive atmospheres - 
Classification of areas. Explosive dust atmospheres. 

 
 
 
 
 
 

Содержание STExB2X05DC012

Страница 1: ...Vac 110 120Vac 50 60Hz 140mA 200mA STExB2X05AC230 230Vac 220 240Vac 50 60Hz 70mA 100mA STExB2X10DC024 SIL 24Vdc 20 28Vdc 605mA 710mA STExB2X10DC048 48Vdc 42 54Vdc 230mA 250mA STExB2X10AC115 115Vac 110...

Страница 2: ...4 X15DC048 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T127 C Db Ta 55 C to 70 C STExB2 X15AC115 X15AC230 Ex db IIC T3 Gb Ta 50 C to 70 C Ex db IIC T4 Gb Ta 50 C to 65 C Ex tb IIIC T131 C Db Ta 55 C to...

Страница 3: ...th the National Electric Code Canadian Electric Code 4 Zones Gas Group Category and Temperature Classification The units can be installed in locations with the following conditions Area Classification...

Страница 4: ...les to the beacon it is necessary to remove the flameproof cover to gain access to the flameproof chamber To access the Ex d chamber loosen the M4 grub screw on the beacon cover Open the enclosure by...

Страница 5: ...h large cross sectional areas such as 2 5mm Earthing Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp terminal to secure the ea...

Страница 6: ...sser 8 Flash Pattern Settings 6 1 Flash Rate Setting The STExB2 beacons can produce different flash patterns as shown in Table 2 The flash patterns are selected by operation of the flash setting DIP s...

Страница 7: ...Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 1...

Страница 8: ...R DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT S...

Страница 9: ...NGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO...

Страница 10: ...Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T...

Страница 11: ...e and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...