European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com Tel: +44 (0)208 743 8880
Document D154-00-101-IS Issue 6 12-09-2022
Sheet 1 of 2
INSTRUCTION MANUAL
GNExCP6A-PB Push Button Manual Call Point
For use in Flammable Gas and Dust Atmospheres
GNExCP6A-PB
Manual Call Point – Push Button
For use in Flammable Gas and
Combustible Dust Atmospheres.
1)
Introduction
The GNExCP6A-PB is a push button manual call
point which is certified to the European and
International Gas and Dust standards. The unit
meets the requirements of the ATEX directive
2014/34/EU, IECEx and UKEX schemes.
The call point can be used in hazardous areas
where potentially flammable gas and dust
atmospheres may be present.
All units have no monitoring resistors, diodes or
zener diodes and are not fitted with an LED
indicator.
The units are Group II, EPL (equipment protection
level) Gb. The equipment is certified ‘Ex db eb IIC
T6 Gb’ and as such may be used in Zones 1 and 2
with flammable gases and vapours with apparatus
groups IIA, IIB & IIC and temperature classes T1,
T2, T3, T4, T5 and T6.
These units are also Group III, EPL Db. The
equipment is certified ‘Ex tb IIIC T75ºC Db’ and as
such may be used in Zones 21 and 22 for
combustible dusts groups IIIA, IIIB & IIIC.
2)
Ratings & Markings
All units have a rating label, which carries the
following important information: -
Unit Type No.:
GNExCP6A-PB Manual Call Point
Input Voltage:
AC voltage 250V Max Current 5.0A Max
DC voltage 250V Max Current 0.25A Max Resistive
load : 0.03A Max Inductive load
DC voltage 125V Max Current 0.5A Max Resistive
load : 0.03A Max Inductive load
DC voltage 75V Max Current 0.75A Max
DC voltage 50V Max Current 1.0A Max
DC voltage 30V Max Current 5.0A Max Resistive
Load; Inductive Load 3.0A Max
DC voltage 12V Max Current 5.0A Max
Code:
Ex db eb IIC T6 Gb
Ex tb IIIC T75 ºC Db
IP66
–40ºC <= Ta <= +70ºC
Certificate No.:
SIRA 09ATEX3286X
IECEx SIR 09.0121X
CSAE 21UKEX3556X
Epsilon x: II 2GD
CE Marking
Notified
2813
Body No.
UKCA Marking
Notified Body No.
0518
Year/Serial No. i.e. 20/1CP6APB000001
WARNING - DO NOT OPEN WHEN AN
EXPLOSIVE ATMOSPHERE MAY BE PRESENT
ELECTROSTATIC HAZARD – CLEAN ONLY
WITH A DAMP CLOTH
3)
Type Approval Standards
The call point has an EC Type examination
certificate issued by SIRA and have been approved
to the following standards: -
EN60079-0:2018 / IEC60079-0:2017
EN60079-1:2014 / IEC60079-1:2014
EN60079-7:2015 / IEC60079-7:2017
EN60079-18:2015 / IEC60079-18:2014
EN60079-31:2014 / IEC60079-31:2013
The equipment is certified for use in ambient
temperatures in the range -40
o
C to +70
o
C and shall
not be used outside this range.
4)
Installation Requirements
Installation of this equipment shall only be carried
out by suitably trained personnel in accordance
with the applicable code of practice e.g.
IEC 60079-14/EN 60079-14
Repair of this equipment shall only be carried out
by the manufacturer or in accordance with the
applicable code of practice e.g. IEC 60079-19/EN
60079-19.
Refer to certificates SIRA 09ATEX3286X, IECEx
SIR 09.0121X and CSAE 21UKEX3556X for
special conditions of safe use.
The certification of this equipment relies on the
following materials used in its construction:
Enclosure:
GRP - Glass Reinforced Polyester
Through enclosure mechanism: Plastic Nylon Zytel
Injection Moulded
Sealing of enclosure and mechanism: O-ring
Acrylonitrile-Butadiene Rubber
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility
of the user to take suitable precautions that prevent
it from being adversely affected, thus ensuring that
the type of protection is not compromised.
“Aggressive substances” - e.g. acidic liquids, gases
or solvents that may affect polymeric materials.
“Suitable precautions” - e.g. regular checks as part
of routine inspections or establishing from the
material’s data sheet that it is resistant to specific
chemicals.
Under extreme conditions the unit may generate an
ignition-capable level of electrostatic charges. The
unit must not be installed in a location where it may
be subjected to external conditions (such as high
pressure steam) which may cause a build-up of
electrostatic charges on non-conducting surfaces.
Cleaning of the unit must only be carried out with a
damp cloth.
5)
Call Point Location and Mounting
The location of the call point should enable ease of
access for operation and testing. The unit should
be mounted using the 4 off fixing holes which will
accept up to M5 sized fixings.
View of base unit showing fixing centres (in mm).
To gain access to the mounting holes in the base
the front cover must be removed.
This is achieved by removing the 4 off M4 cap
head bolts holding on the cover.
Once the screws are removed the cover will hang
down out of the way to gain access to the Ex e
terminal block, the internal earth terminal and
mounting hole recesses.