Ambient Temperature Range 

-20°C to +55°C 

IP Rating 

IP64 to EN/IEC60079-0 

IP66 to EN60529 
To maintain the ingress protection rating, the two off cable entries 
must be fitted with suitably rated, certified cable entry and/or 
blanking devices during installation. 

Type Rating 

Per UL50E / NEMA250: 4 / 4X / 3R / 13

 

 
Installation must be carried out in compliance with the latest 
issue of the following standards: 
 
EN60079-14 / IEC60079-14: Explosive atmospheres - 
Electrical installations design, selection and erection 
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres - 
Classification of areas. Explosive gas atmospheres 
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres –  
Classification of areas. Explosive dust atmospheres 
 

5)  Special Conditions of Use 

 

When  used  for  a  Group  III  application,  the  surface  of  the 
enclosure  may  store  electrostatic  charge  and  become  a 
source  of  ignition in applications with  a low relative  humidity 
<~30% relative humidity where the surface is relatively free of 
surface contamination such as dirt, dust, or oil. 
 
Guidance  on  protection  against  the  risk  of  ignition  due  to 
electrostatic discharge can be found in EN TR50404 and IEC 
TR60079-32. 

 

End  user shall  adhere  to  the  manufacturer’s  installation  and 
instruction  when  performing  housekeeping  to  avoid  the 
potential for hazardous electrostatic charges during cleaning, 
by using a damp cloth. 
 
To  maintain  the  ingress  protection  rating  and  mode  of 
protection, the cable entries must be fitted with suitably rated, 
certified  cable  entry  and/or  blanking  devices  during 
installation.  
 
Equipment  with  the  flare  horn  shall  not be  installed  with  the 
flare higher than horizontal (to avoid accumulation of dust). 
 
The equipment incorporates metal parts isolated from earth, 
having capacitance values exceeding the limits permitted in 
the standards of certification. Mounting bracket – 10.33pF. 

 

6)  Product Mounting and Access 
 

6.1. 

Location and Mounting 

 

The location of the sounder should be made with due regard 
to  the  area  over  which  the  warning  signal  must  be  audible. 
They  should  only  be  fixed  to  services  that  can  carry  the 
weight of the unit. 

 

The E2x sounder should be secured to any flat surface using 
the  three  7mm  fixing  holes  on  the  stainless  steel  U  shaped 
mounting bracket.  See  Figure  1.  The  required  angle  can  be 
achieved  by  loosening  the  two  large  bracket  screws  in  the 
side  of  the  unit,  which  allow  adjustment  of  the  sounder  in 
steps  of  18°.  On  completion of  the  installation  the  two  large 

bracket  adjustment  screws  on  the  side  of  the  unit  must  be 
fully tightened to ensure that the unit cannot move in service. 

 

 

Fig. 1a Fixing Location for Sounder Flare 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Fig. 1b Fixing Location for Sounder Radial 

 

6.2. 

Access to the Enclosure 

 

 

Warning – High voltage may be 
present, risk of electric shock.  
DO NOT open when energised, 
disconnect power before opening. 

 

Warning – Hot surfaces. External 
surfaces and internal components 
may be hot after operation, take 
care when handling the equipment. 

 

To access the enclosure, remove the four M4 posi pan head 
screws, M4 spring and plain washers and withdraw the cover.  
 

 

 

 

 

Fig. 2 Accessing the Enclosure. 

(Appropriate cable entry devices 
to be customer supplied)  

Cover  

M4 Cover 
Screw 

M4 Spring 
Washer 

M4 Plain 
Washer 

Содержание E2xS2FDC024

Страница 1: ...ON HUMIDE HAUT TENSION RISK DE CHOC ATTENDEZ 5 MINUTES APRES AVOIR DEBRANCHE L ALIMENTATION AVANT D OUVRIR LA BOITIER 3 Rating Marking Information 3 1 ATEX IECEx UKEx certification The E2xS2 alarm hor...

Страница 2: ...l Electric Code CEC Class Zone ratings Canada Standards CAN CSA C22 2 No 60079 0 Ed 4 02 2019 Explosive Atmospheres Part 0 Equipment General Requirements CAN CSA C22 2 No 60079 7 Ed 2 Explosive Atmosp...

Страница 3: ...ction the cable entries must be fitted with suitably rated certified cable entry and or blanking devices during installation Equipment with the flare horn shall not be installed with the flare higher...

Страница 4: ...ons are to be made into the terminal blocks on the PCBA located in the enclosure See section 6 of this manual for access to the enclosure Wires having a cross sectional area between 0 5 mm to 2 5mm ca...

Страница 5: ...1 0 0 1 544Hz 100mS 440Hz 400mS NF S 32 001 40 Tone 17 Tone 23 0 1 1 0 0 1 800Hz 0 25 sec on 1 sec off Intermittent 39 Tone 45 Tone 34 1 0 1 0 0 1 2000Hz Continuous 38 Tone 45 Tone 9 0 0 1 0 0 1 1000...

Страница 6: ...IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 001 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xS1R E2xS1F E2xS2F SOUNDER WIRING DIAGRAMS INTRODUCTION RSR 05 08 2020 NT...

Страница 7: ...Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standar...

Страница 8: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 9: ...on Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 6007...

Страница 10: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: