background image

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D209-00-101-IS

 

Issue 1

 

20-08-22

 

 

Sheet 2 of 5

 

 

Certificate No. 

DEMKO 06ATEX 0421554X 
IECEx ULD 14.0012X 
UL21UKEX2135X

 

ATEX Mark, Equipment 
Group and Category: 

 

II 3G 
II 3D

 

CE Marking 
 

 

 

UKCA Marking 

 

 

 

3.2. NEC & CEC Ratings 
 
NEC & CEC Class / Division Ratings for US / 
Canada 

 

Standards 

UL 121201-2021 (Ed. 9) 
CAN/CSA C22.2 No. 213-17 (Ed. 3) 

Ratings 

E2XL15: 

Class I, Div 2,  

ABCD   T3C Ta -20°C to +55°C 

Class I, Div 2,  

ABCD   T4 Ta -20°C to +40°C 

Class II, Div 2,   FG  

T6 Ta -20°C to +55°C 

Class III, Div 1&2  

Ta -20°C to +55°C 

E2XL25: 

Class I, Div 2, ABCD T2C Ta -20°C to +55°C 
Class I, Div 2, ABCD T2D Ta -20°C to +40°C 
Class II, Div 2, FG T5 Ta -20°C to +55°C 
Class II, Div 2, FG T6 Ta -20°C to +40°C 
Class III, Div 1&2 Ta -20°C to +55°C 

Installation must be carried out in compliance with the National 
Electric Code / Canadian Electric Code 

 

NEC Class / Zone ratings US 

 

Standards 

UL 60079-0 (Ed. 7): 

Explosive Atmospheres - part 0: Equipment - General 
Requirements  

UL 60079-7 (Ed. 5): 

Explosive Atmospheres - Equipment Protection by Increased 

Safety "e" 

UL 60079-31 (Ed. 2) 

Explosive Atmospheres - Equipment Dust Ignition Protection 

by Enclosure "t" 

Ratings 

E2XL15: 

Class I Zone 2 AEx ec IIC T4 Gc Ta -20°C to +55°C 
Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C 

E2XL25: 

Class I Zone 2 AEx ec IIC T2 Gc Ta -20°C to +55°C 
Zone 22 AEx tc IIIC 85°C Dc Ta -20°C to +40°C 
Zone 22 AEx tc IIIC 100°C Dc Ta -20°C to +55°C 

Installation must be carried out in compliance with the National 
Electric Code. 

 
 
 
 

CEC Class / Zone ratings Canada 

 

Standards 

CAN/CSA C22.2 No. 60079-0 (Ed. 4) 02/2019 

Explosive Atmospheres - Part 0: Equipment - General 
Requirements  

CAN/CSA C22.2 No. 60079-7 (Ed. 2) 

Explosive Atmospheres - Equipment Protection by Increased 

Safety "e" 

CAN/CSA C22.2 No. 60079-31 (Ed. 2) 

Explosive Atmospheres - Equipment Dust Ignition Protection 

by Enclosure "t" 

Rating 

E2XL15::

 

Ex ec IIC T4 Gc Ta -20°C to +55°C 
Ex tc IIIC T85°C Dc Ta -20°C to +55°C 

E2XL25: 

Ex ec IIC T2 Gc Ta -20°C to +55°C 
Ex tc IIIC 85°C Dc Ta -20°C to +40°C 
Ex tc IIIC 100°C Dc Ta -20°C to +55°C 

Installation must be carried out in compliance with the Canadian 
Electric Code 

 

4)  Zones, Gas Groups, Category and 

Temperature Classification 

 

When connected to an approved system the E2X alarm horn 
may be installed in: 
 

Area Classification 

Zone 2 

Explosive gas air mixture not likely to occur in 
normal operation, and if it does, it will only 
exist for a short time. 

Zone 22 

Explosive dust air mixture not likely to occur in 
normal operation, and if it does, it will only 
exist for a short time. 

Gas Groupings 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

Temperature Classification for Gas Applications 

T1 

450ºC  

T2 

300ºC 

T3 

200ºC (E2XL15 Only) 

T4 

135°C (E2XL15 Only) 

Dust Groupings 

(ATEX / IECEx / UKEX only) 

Group IIIA 

Combustible Flyings 

Group IIIB 

Non-conductive Dust 

Group IIIC 

Conductive Dust 

Maximum Surface Temperature for Dust Applications 

(ATEX / IECEx / UKEX only) 

E2XL15: 
 

85°C 

E2XL25: 
 

100°C 
85°C (Only up to 40°C Ambient) 

Содержание E2xL15R

Страница 1: ...Rating Marking Information 3 1 ATEX IECEx UKEx certification The E2xL15 and E2xL25 loudspeakers comply with the following standards Standards EN IEC 60079 0 2018 IEC60079 0 2017 Ed 7 Explosive Atmosp...

Страница 2: ...C Zone 22 AEx tc IIIC 100 C Dc Ta 20 C to 55 C Installation must be carried out in compliance with the National Electric Code CEC Class Zone ratings Canada Standards CAN CSA C22 2 No 60079 0 Ed 4 02 2...

Страница 3: ...2 End user shall adhere to the manufacturer s installation and instruction when performing housekeeping to avoid the potential for hazardous electrostatic charges during cleaning by using a damp cloth...

Страница 4: ...es and cable glands must be used as per table below Ambient Temp 40 C 45 C 50 C 55 C Min Rating of cables and cable glands 90 C 95 C 100 C 105 C If a high IP Ingress Protection rating is required then...

Страница 5: ...its leads as short as possible a spacing of at least 1 16 1 58mm must be provided through air and over surfaces between uninsulated live parts 10 Low Impedance Wiring 10 1 L15 Low Impedance A 4 way te...

Страница 6: ...ACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 101 R S RAIT R N...

Страница 7: ...S TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERI...

Страница 8: ...Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standar...

Страница 9: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 10: ...on Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 6007...

Страница 11: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: