European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D209-00-401-IS
Issue 1
20-08-22
Sheet 1 of 5
INSTRUCTION MANUAL
E2xBL2 LED Beacon
For use in Hazardous Locations
E2XBL2
1) Product Table
Ensure the system power supply is capable of providing the maximum current required for all units. Review associated cable
size, length and quantity of units on each circuit.
2) Warnings
DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGISED
POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
NE PAS OUVRIR UN PRESENCE
D’ATMOSPHERE EXPLOSIVE
NE PAS OUVRIR ENERGIE
DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L’ALIMENTATION AVANT
D’OUVRIR LA BOITIER
3) Rating & Marking Information
3.1. ATEX / IECEx / UKEx certification
The E2xBL2 LED beacon complies with the following
standards:
Standards
EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7):
Explosive Atmospheres - Equipment. General Requirements
EN IEC 60079-7:2015 +A1:2018 / IEC 60079-7:2018 (Ed. 5.1):
Explosive Atmospheres - Equipment Protection by Increased
Safety "e"
EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2):
Explosive Atmospheres - Equipment Dust Ignition Protection by
Enclosure "t"
Ratings
E2XBL2:
Ex ec IIC Gc T4 Ta -20°C to +55°C
Ex tb IIIC Dc T85°C Ta -20°C to +55°C
Certificate No.
DEMKO 06ATEX 0421554X
IECEx ULD 14.0012X
UL21UKEX2135X
ATEX Mark, Equipment
Group and Category:
II 3G
II 3D
CE Marking
UKCA Marking
Model
Nom. Voltage
Voltage Range
Max Operating
Current*
E2xBL2DC024
24Vdc
18-54Vdc
346mA
E2xBL2AC115
115-120Vac
50/60Hz
N/- 10%
102.4mA
E2xBL2AC230
220-230Vac
50/60Hz
N/- 10%
49.4mA
The current levels shown above are for the worst-case input voltage and flash setting resulting in max. current.
Table 1: Electrical Ratings.