Document No. D211-00-471-IS-SC           Issue A          27-11-19                         Sheet 4 of 8

 

       

--   

          ++  

External 
Earth  

Internal 
Earth  

-

+

- - + +

- - + +

- - + +

7)  Cable Connections

 

 

Electrical connections are to be made into the terminal blocks 
on  the  PCBA  located  in  the  enclosure.  See  section  5  of  this 
manual for access to the enclosure.  
Wires  having  a  cross  sectional  area  between  0.5  mm²  to 
2.5mm²  can  be  connected  to  each  terminal  way.  If  an  input 
and  output  wire  is  required  the  2-off  +/-  terminals  can  be 
used. If fitting 2-off wires to one terminal way the sum of the 
2-off  wires  must  be  a  maximum  cross  sectional  area  of 
2.5mm².  Strip  wires  to  8mm.  Wires  may  also  be  fitted  using 
ferrules.  Terminal  screws  need  to  be  tightened  down  with  a 
tightening  torque  of  0.56  Nm  /  5  Lb-in.  When  connecting 
wires to the terminals great care should be taken to dress the 
wires so that when the cover is inserted into the chamber the 
wires  do  not  exert  excess  pressure  on  the  terminal  blocks. 
This  is  particularly  important  when  using  cables  with  large 
cross sectional areas such as 2.5mm². 

 

8)  Wiring 

 

2-off  2-way  terminal  blocks  are  provided  on  the  beacon  for 
power. There are 2-off +ve & 2-off 

–ve terminals in total. 

 

8.1 

Wiring Diagrams 

 
 

 
 
 
 
 
 
 

Fig. 3 D2xB1LD3 DC Simplified Block Diagram  

 
 

 
 

 

Fig. 4 D2xB1LD3 Terminals 

 
8.2 

Line Monitoring 

 

DC  reverse  line  monitoring  can  be  used  if  required.  All 
beacons  have  a  blocking  diode  fitted  in  their  supply  input 
lines.  An  end  of  line  monitoring  resistor  can  be  connected 
across the +ve and 

–ve terminals. If an end of line resistor is 

used it must have the following values: 
 
24V DC applications 
 
Minimum resistance 3K9 Ohms 

Minimum Power 0.5W 

Minimum resistance 1K Ohms 

Minimum Power 2.0W 

 

The resistor must be connected directly across the +ve and  
-ve terminals as shown in the following drawing. Form the 
resistor legs as shown in Fig. 5a, remove the +ve and 

–ve 

terminal plugs and fit the resistor across the two terminal 
plugs before refitting them to the PCBA as shown in Fig. 5b. 
A spacing of at 

least 1/16” (1.58mm)

 

must be provided 

through air and over surfaces between uninsulated live parts. 

 

 

 

Fig. 5a End of Line Resistor Forming 

 

 
 
 
 

 
 
 

 
 
 

 

 

Fig. 5b End of Line Resistor Placement 

 

9)  Earthing 

 

The  unit  has  both  internal  and  external  earth  points,  (please 
see fig 6). 
 
Internal earthing  connections should be made  to  the  internal 
earth  point  on  the  PCBA,  (please  see  fig  6).  The  earth 
conductor  should  be  at  least  equal  in  size  and  rating  to  the 
incoming  power  conductors.  The  internal  earth  bonding  wire 
connects the cover earth point to the internal earth terminal in 
the base. 
 
External  earth  connections  should  be  made  to  the  M5  earth 
stud,  using  a  ring  crimp  terminal  to  secure  the  earth 
conductor  to  the  earth  stud.  The  external  earth  conductor 
should be at least 4mm

2

 in size. The external earth crimp ring 

should  be  located  between  the  two  M5  plain  washers 
provided  and  securely  locked  down  with  the  M5  spring 
washer and M5 nut. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Fig 6 Earth locations 

 
 
 
 
 

End of Line Resistor 

-

 

               

+

 

Содержание D2xB1LD3DC024

Страница 1: ...when powered from the same source 2 2 Private Mode Fire Alarm Ratings All models are approved for use as a Visual Appliance for use in Private Mode Fire Alarm Systems in accordance with UL1638 Fifth...

Страница 2: ...79 10 2 Explosive atmospheres Classification of areas Explosive dust atmospheres 2 7 Ingress Protection Ratings The product is rated for ingress Protection as follows IP rating IP66 Type rating per UL...

Страница 3: ...th of the cable runs The cable size selected must have the necessary capacity to provide the input current to all of the sounders connected to the line When selecting the cable size consideration must...

Страница 4: ...erminals 8 2 Line Monitoring DC reverse line monitoring can be used if required All beacons have a blocking diode fitted in their supply input lines An end of line monitoring resistor can be connected...

Страница 5: ...Flashing 1 33Hz 11 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant stand...

Страница 6: ...0 15 15 30 45 60 75 90 90 30 45 60 75 Fig 9 Horizontal dispersion angles for wall mounting Table 2 Horizontal Light Output Dispersion for Wall Mounting Viewing Angle of Rating Intensity cd at 1Hz fla...

Страница 7: ...rate 0 100 80 1 77 1 77 3 82 1 5 90 72 1 69 4 69 5 73 9 10 90 72 1 69 4 69 5 73 9 15 90 72 1 69 4 69 5 73 9 20 90 72 1 69 4 69 5 73 9 25 90 72 1 69 4 69 5 73 9 30 75 60 1 57 8 58 0 61 6 35 75 60 1 57...

Страница 8: ...om operating current Max operating current D2xB1LD3DC024 24Vdc Regulated 16 33Vdc 1Hz 60fpm 153mA 465mA 1 33Hz 80fpm 189mA 488mA 1 5 Hz 90fpm 203mA 456mA 2Hz 120fpm 248mA 528mA For Public Mode or priv...

Отзывы: