E2S D1 B2LD2 Series Скачать руководство пользователя страница 1

INSTRUCTION MANUAL 

D1xB2LD2 
LED Beacon  
For use in Hazardous Locations 

 

E2S Warning Signals

      Impress House, Mansell Road, Acton, London W3 7QH

www.e2s.com

 

Tel: +44 (0)208 743 8880

Document No. D191-00-401-IS

 

Issue 3

 

28-11-22

Sheet 1 of 6

 

 
 

D1xB2LD2 

 
 
 

1)  Warnings 

 

 DO NOT OPEN WHEN AN EXPLOSIVE 

ATMOSPHERE IS PRESENT 

 DO NOT OPEN WHEN ENERGISED 

 POTENTIAL ELECTROSTATIC CHARGING 

HAZARD - CLEAN ONLY WITH A DAMP 
CLOTH 

 DO NOT PAINT 

 TO REDUCE THE RISK OF IGNITION OF 

HAZARDOUS ATMOSPHERES, THE FIRST 
CONDUIT RUN MUST HAVE A SEALING 
FITTING CONNECTED WITHIN 18 INCHES 
OF ENCLOSE. SUBSEQUENT CONDUIT 
RUNS MUST HAVE A SEALING FITTING 
CONNECTED AS CLOSE AS PRACTICAL TO 
THE WALL OF THE ENCLOSURE, BUT IN 
NO CASE MORE THAN THE SIZE OF THE 
CONDUIT OR 50MM, WHICHEVER IS THE 
LESSER. 

 TO PREVENT IGNITION OF GROUP A, B, C 

AND D ATMOSPHERES - SEE       
INSTRUCTION FOR CHEMICAL 
COMPATIBILITY 

 

Avertissement: 

 

 NE PAS OUVRIR UN PRESENCE 

D’ATMOSPHERE EXPLOSIVE 

 NE PAS OUVRIR ENERGIE 

 DANGER POTENTIEL CHARGE 

ÉLECTROSTATIQUE - NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE 

 NE PAS PEINTURER 

 POUR RÉDUIRE LE RISQUE 

D'INFLAMMATION DES ATMOSPHÈRES 
DANGEREUSES, LE PREMIER CONDUIT DE 
CONDUIT DOIVENT AVOIR UN RACCORD 
D'ÉTANCHÉITÉ RACCORDÉ À MOINS DE 18 
POUCES DE L'ENFERMEMENT. POUR 
SUBSÉQUENT LES

 

CONDUITES DE 

CONDUIT LA DISTANCE ENTRE LA 
SURFACE DE LA MASSE DE REMPLISSAGE 
AU PLUS PRÈS DE L’ENVELOPPE DOIT 
ÊTRE AUSSI PETITE QUE CE QUI EST 
RÉALISABLE MAIS EN AUCUN CAS 

SUPÉRIEURE À LA PLUS PETITE DES 
DIMENSIONS CORRESPONDANT À LA 
TAILLE DU CONDUIT OU À 50 MM. 

 POUR PRÉVENIR L'INFLAMMATION DES 

ATMOSPHÈRES DES GROUPES A, B, C ET 
D-VOIR L'INSTRUCTION POUR LA 
COMPATIBILITÉ CHIMIQUE 

 

2)  Rating & Marking Information 

 

2.1 NEC & CEC Class / Division Ratings for US / 
Canada 

 
The D1xB2LD2 LED beacons comply with the following 
standards: 
 

UL 1203 (Ed. 5) 2015 
CSA C22.2 No. 30-M1986 (Ed. 1) 2003 
CSA C22.2 No. 25 (Ed. 4) 2017 
CSA C22.2 No. 205 (Ed. 3) 2017 

 
The D1xB2LD2 LED Beacon is rated as follows: 
 

Class I Div 1 Group ABCD T5 Ta -55°C to +80°C 
Class I Div 1 Group ABCD T6 Ta -55°C to +75°C 
Class II Div 1 Group EFG T5 Ta -55°C to +80°C 
Class III Div 1 Ta -55°C to +80°C 

 

Installation must be carried out in compliance with the 
National Electric Code / Canadian Electric Code 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание D1 B2LD2 Series

Страница 1: ...R UNIQUEMENT AVEC UN CHIFFON HUMIDE NE PAS PEINTURER POUR R DUIRE LE RISQUE D INFLAMMATION DES ATMOSPH RES DANGEREUSES LE PREMIER CONDUIT DE CONDUIT DOIVENT AVOIR UN RACCORD D TANCH IT RACCORD MOINS D...

Страница 2: ...units the certification approval has validated continuous use up to 38 C ambient and are for transient use up to 80 C ambient Certificate No DEMKO 19 ATEX 2009X IECEx ULD 19 0006X UL21UKEX2130X ATEX M...

Страница 3: ...sification of areas Explosive gas atmospheres EN60079 10 2 IEC60079 10 2 Explosive atmospheres Classification of areas Explosive dust atmospheres The installation of the units must also be in accordan...

Страница 4: ...s or blanking plugs For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in explosive gas atmospheres a minimum ingress protection rating of IP5...

Страница 5: ...000001 Steady Low Power Flashing 1Hz Flashing Triple Strike 100000 Flashing 1Hz Flashing Double Strike Flashing Triple Strike 101000 Flashing 1 5Hz Flashing 2Hz Flashing Double Strike 010000 Flashing...

Страница 6: ...h the new lens cover Fig 10 Replacement of beacon lens cover Fit the wire guard back onto the housing over the new lens cover aligning the fixing holes of the guard lens cover and housing Refit the fi...

Страница 7: ...Page left Intentionally blank...

Страница 8: ...AR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT...

Страница 9: ...Page left Intentionally blank...

Страница 10: ...Gb II 2D Ex tb IIIC T95 C T169 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Compatibility...

Страница 11: ...Ex d IIC T6 T3 Gb II 2D Ex tb IIIC T95 C T169 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic...

Страница 12: ...Page left Intentionally blank...

Отзывы: