1.  Product Table 

 

Unit Type Code 

Nominal 

Input Voltage 

Nominal 

Input Current 

Max I/P Voltage  

Sound 

Pressure Level 

dB(A) 

Max* 

Nom

.†

 

BExS110DDC012 / 

BExS110DDC012-R 

12Vdc 

195mA 

15V 

Flare: 

117dB(A) 

Radial: 

115dB(A) 

Flare: 

110dB(A) 

Radial: 

110dB(A) 

BExS110DDC024 / 

BExS110DDC024-R 

24Vdc 

265mA 

30V 

BExS110DDC048 / 

BExS110DDC048-R 

48Vdc 

130mA 

60V 

BExS110DAC115 / 

BExS110DAC115-R 

115Vac 

110mA 

126V 

BExS110DAC230 / 

BExS110DAC230-R 

230Vac 

56mA 

253V 

*Max = Tone 4 

Nom. = Tone 44 

 
The table shows the input current taken by the various sounders. 
The current levels shown above are for the 440Hz Continuous tone @ nominal input voltage.  
Nominal current at nominal voltage. 

Table 1: Electrical Ratings. 

 

It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity 
to provide the input current to all of the units. 

 

The above table shows the input current taken by the various sounders and shows the maximum voltage at which the sounders can 
be operated: 

 

The input current will vary according to the voltage input level and the frequency of the tone selected. 

 

2.  Warnings 

  

 

  DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT 

  DO NOT OPEN WHEN ENERGIZED 

  POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A  DAMP CLOTH 

  COVER BOLTS CLASS A4-80 

  USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER 

40°C 

 

Содержание BExS110D

Страница 1: ...44 The table shows the input current taken by the various sounders The current levels shown above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Ele...

Страница 2: ...ation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Appli...

Страница 3: ...tightened to ensure that the unit cannot move in service Fig 1a Fixing Location for Sounder Radial Fig 1b Fixing Location for Sounder Flare 7 Access to the Flameproof Enclosure To access the Ex d cha...

Страница 4: ...are both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming...

Страница 5: ...d a minimum power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor must be connected directly across the ve and ve terminals as shown in the...

Страница 6: ...current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repair overhaul and reclamation EN 60079 17 IEC60079 17 Explosive atmospheres Electrical installations inspection and...

Страница 7: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Страница 8: ...ISARD R N POTTS OF NTS 1 1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Optional Line Monitoring Heade...

Страница 9: ...TE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F...

Страница 10: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db eb IIB or I...

Страница 11: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Страница 12: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Страница 13: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Страница 14: ...Page left Intentionally blank...

Страница 15: ...Page left Intentionally blank...

Страница 16: ...Page left Intentionally blank...

Отзывы: