The current levels taken by the each loudspeaker will depend 
on which output tapping has been selected (see section 13 of 
this instruction manual). BExDL25D 70V and 100V Line units 

have  output  levels  of  25W,  12.5W,  6W  and  2W;  BExDL15D 
70V and 100V Line units have output levels of 15W, 7.5W, 3W 

and 1W. 

9) 

  Cable Selection 

When selecting the cable size consideration must be given to 

the current that each  unit draws, the number of loudspeakers 
on the line and the length of the cable runs. 

 
SAFETY  WARNING:  If  the  loudspeakers  are  used  at  high 
ambient  temperatures,  i.e.  over  +40ºC,  then  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting  cables  must  be  used,  with  a  rated  service 

temperature of at least 110ºC. 
 

10) 

  Earthing 

 

All loudspeakers must  be  connected  to  a good  quality earth. 
The  units  are  provided  with  internal  and  external  earthing 

terminals  which  are  both  located  on  the  flameproof  cover 
section of the unit (see figures 2 and 3).  

 

 

 
When  using  the  internal  earth  terminal  ensure  that  the 
stainless steel  M4  flat  washer  is between the incoming earth 
wire and the enclosure. 
 
When using the external earth terminal a cable crimp lug must 
be used.  The cable lug should be located between the two M5 

stainless  steel  flat  washers.  The  M5  stainless  steel  spring 
washer  must  be fixed  between  the  outer flat  washer  and  the 
M5 stainless steel nut to ensure that the cable lug is secured 
against loosening and twisting.  
 
The  internal  earth  bonding  wire  ensures  that  a  good  quality 
earth  is  maintained between the flameproof chamber  casting 

and the flameproof cover casting. 
 

11) 

 Cable Glands

 

 

The BExDL25D and BExDL15D loudspeakers have dual cable 
gland  entries  which  have  an  M20  x  1.5  entry  thread  as 
standard.  Only cable  glands approved for  Ex ‘d’  applications 
can be used, which must be suitable for the type of cable being 
used and also meet the requirements of the Ex ‘d’ flameproof 

installation standard  EN 60079-142008 / IEC60079-14:2007. 

When  only  one  cable  entry  is  used  the  other  one  must  be 
closed with an Ex ‘d’ flameproof blanking plug, which must be 
suitably approved for the installation requirements.  

 
For combustible dust applications, the cable entry device and 

blanking  elements  shall  be  in  type  of  explosion  protection 
increased safety "e" or flameproof enclosure "d" and shall have 
an IP 6X rating according to EN60529:1992. 
SAFETY  WARNING:  If  the  loudspeakers  are  used  at  high 
ambient  temperatures,  i.e.  over  +40ºC,  then  the  cable entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting  cable  glands  must  be  used,  with  a  rated  service 

temperature of at least 110ºC. 
 

12) 

  Cable Connections 

 

The  cable connections  are  made  into  the terminal blocks  on 
the  pcb  assembly  located  in  the  flameproof  enclosure.  See 

section  7  of  this  manual  for  access  to  the  flameproof 
enclosure. The 70V and 100V Line loudspeakers are fitted with 

a  five  way  terminal  block.  Terminal  A is  common  and one of 
the other terminals B, C, D or E should be selected depending 

on what output level is required (see table below). 

A

B

C

D

E

 

 

Terminals 

BExDL25D (25W)             BExDL15D (15W) 

 
A - B 

 

     25W   

 

15W 

A - C 

 

     12.5W 

 

7.5W 

A - D 

 

     6W   

 

3W 

A - E 

 

     2W   

 

1W 

 

A single wire with a cross sectional area of up to 4mm² can be 
connected to each terminal way or if an input  and output wire 
is  required  two  2.5mm²  wires  can  be  connected  to  each 
terminal  way.  When  connecting  wires  to  the  terminals  great 
care should be taken to dress the wire so that when the cover 

is  inserted  into  the  chamber  the  wires  do  not  exert  excess 
pressure on  the  terminal blocks. This is  particularly  important 

when  using  cables  with  large  cross  sectional  areas  such  as 
2.5mm² and above. 

2 off M20  

Cable Entries 

Internal Earth Terminal 

Figure 3 

Internal Bonding 
Wire Terminal 

Figure 4 

BExDL25D and BExDL15D 70V and 100V Line Loudspeakers 