E2S BExCP3A-BG Скачать руководство пользователя страница 2

 
 

 

 

 

European Safety Systems Ltd.

  Impress House, Mansell Road, Acton, London W3 7QH 

 

 

 

 

 

[email protected]  Tel: +44 (0)208 743 8880 

Document D150-00-155-IS   Issue 2   11-08-2022 

 

 

Sheet 2 of 3 

 

 

 

www.e2s.com  Fax +44 (0)208 740 4200 

 

6) 

Earthing 

The  unit  has  both  internal  and  external  earth 
terminals. 
It  is  recommended  that  a  cable  crimp  lug  is  used 
on the earth wires. 
The  internal  earth  wire  is  placed  under  an  earth 
clamp  which  will  stop  the  cable  twisting.  This 
secured by an M4 screw and spring washer. 
The  external  earth  lug  should  be  located  between 
the two M5 washers provided and securely locked 
down with the M5 spring washer and two locknuts. 
 

 

Internal Earth 
terminals   

 

External 

 

 

               Earth Stud 

 

Ex e terminal block 

 
Note: Depending on options chosen an 8-Way DIN 
Rail or 6-Way terminal block may be selected. 
 

7) 

Cable connections 

There  are  3  off  cable  entry  holes  suitable  for 
M20x1.5  Ex  e  approved  cable  glands  or  stopping 
plugs with a minimum ingress protection of IP66. 
 
The unit can be wired in a number of different ways 
depending  on  the  resistor  combination  selected. 
Refer to wiring schematic D150-06-051 for detail. 
 
EOL (End of line) device: 
resistor – ExxxR / diode – ED1 / zener – ExxxZ  
Series (In line) device: 
resistor – SxxxR / diode – SD1 / zener – SxxxZ 
Microswitch 1 = M/S 1 
 
When  wiring  to  Increased  Safety  terminal 
enclosures, you are only permitted to connect one 
wire into each way on the terminal block, unless a 
pair of wires are crimped into a suitable ferrule.  

For the six-way terminal block wire sizes allowable 
are 0.5mm² to 4.0mm². For the 8-way DIN rail wire 
sizes allowable are 0.5mm² to 2.5mm² 
 
Leads connected to the terminals shall be insulated 
for the appropriate voltage and this insulation shall 
extend  to  within  1mm  of  the  metal  of  the  terminal 
throat.  They  shall  only  be  installed  and  wired  with 
cable  in  an  ambient  temperature  of  -10°C  to 
+80°C. 
 
All  terminal  screws,  used  or  unused,  shall  be 
tightened down to between 0.5 Nm and 0.7 Nm. 
 

Voltage 
option 

Max 
Voltage  

Min resistor value 
allowable in module 
Type C unit (1.5W) 

6 V dc 

6 V dc 

27 ohms 

12V dc 

12 V dc 

110 ohms 

24V dc 

24 V dc 

430 ohms 

48V dc 

48 V dc 

1K8 ohms 

Table 1 

 

7.1)    Current Limitations 

The  maximum  allowable  current  is  determined  as 
the smallest value from the following scenarios:

 

 

1. 

When  both  module  resistor  values  are  the 
same  as  or  above  the  minimum  range  of 
values  shown  in  table  1,  the  current  is  not 
further limited. 
 
However, when either resistor value is 

lower

 

than those shown in table 1, the current must 
be limited to the values given in table 2. 
 

Voltage 
option 

Max 
Voltage  

Max current when 
resistor values lower 
than minimum 

6 V dc 

6 V dc 

250mA 

12V dc 

12 V dc 

125mA 

24V dc 

24 V dc 

62mA 

48V dc 

48 V dc 

31mA 

Table 2 

 

For example, if a 24V DC unit is fitted with a 
series  resistor  of  270  ohms,  the  maximum 
current of the unit would be reduced to 62mA 
since the resistance is less than the minimum 
430 ohms allowable at this voltage. 
 

E2S  recommends  a  minimum  resistor  value 
of  100  ohms  for  a  Series  device  and  180 
ohms for an EOL device fitted to a 24V unit. 
 

2. 

If  a  diode  module  is  pre-fitted  as  either  an 
EOL  or  Series  Device,  the  following  current 
limitation applies: 

 

Unit Voltage 

Max. Diode Current 

48V DC 

0.75A 

6, 12 & 24V DC 

2.0A  

 
3. 

If a Zener diode module is pre-fitted as either 
EOL  or  Series  device,  the  following  current 
limitation applies: 

 

Zener 
Voltage 

Max. Input 
Voltage 

Max. Current 

3.3V 

56V DC 

230mA 

4.7V 

162mA 

5.1V 

149mA 

5.6V 

136mA 

6.2V 

122mA 

6.8V 

112mA 

10V 

76mA 

12V 

63mA 

 

8) 

Testing unit operation 

The  push  button  unit  can  be  tested  without  the 
need to replace any element.  
 
To  test,  lift  the  cover  lift  flap  to  reveal  the  push 
button. The button should be pressed into the body 
to  activate  the  unit  and  place  it  into  the  operated 
condition. 
 

 

 

The  call  point  switch  will  now  change  over  its 
contacts to operate the alarm. 
Once testing is complete the unit needs to be reset 
from the operated condition.  
 
Rotate  the  push  button  anticlockwise  by  an  angle 
of  55º,  see  guide  alignment  marks  on  button  and 
cover,  shown  below  (1).  The  push  button  should 
pop back up to its original position. 
Ensure that the push button has also twisted back 
clockwise  by  55º  to  its  original  position  see  guide 
marks on button and cover, shown below (2). 
The unit is now reset. 
  

 

 

1. On operated unit 

         2. Button should pop 

Twist push button 

         up and twist back to 

Anticlockwise 55º 

         original position 

to reset 

 

          

 

 
Note: use alignment 
marks circled to 
indicate the push 
button’s status 
/position.  
 
Unit currently shown 
as ‘standby 
condition’ 
 

Resetting an operated unit is the same as resetting 
a tested unit. 
 
 
 
 

Содержание BExCP3A-BG

Страница 1: ...ion certificate issued by SIRA and have been approved to the following standards EN60079 0 2018 IEC60079 0 2017 EN60079 1 2014 IEC60079 1 2014 EN60079 7 2015 IEC60079 7 2017 EN60079 18 2015 IEC60079 1...

Страница 2: ...t is determined as the smallest value from the following scenarios 1 When both module resistor values are the same as or above the minimum range of values shown in table 1 the current is not further l...

Страница 3: ...re fault tolerance of 0 at SIL 2 The product was assessed against failure modes Failure to close a contact when the call point is struck with specified force Failure to open a contact when the call po...

Страница 4: ...CP3A PB BExCP3B PB BExCP3C PB BExCP3D PB BExCP3E PB Acionador Manual de Alarme com Bot o Pulsador de Rearme Rotativo por Chave BExCP3A PT BExCP3B PT BExCP3C PT BExCP3D PT BExCP3E PT Certificado Sira 0...

Страница 5: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Страница 6: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Страница 7: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Страница 8: ...os s o certificados como Ex db eb IIC T6 Gb e como tais podem ser utilizados nas Zonas 1 e 2 com gases e vapores inflam veis e com os grupos de aparelhos IIA IIB IIC e classes de temperatura T1 T2 T3...

Страница 9: ...e IIIC Os equipamentos s o certificados somente para uso em temperaturas entre 40o C e 65o C e n o dever o ser utilizados fora desta faixa Acionador Manual de Alarme Quebra Vidro BExCP3D BG Acionador...

Страница 10: ...ser realizado somente por pessoal adequadamente treinado em conformidade com o c digo de pr tica aplic vel ex IEC 60079 19 EN 60079 19 7 A certifica o destes equipamentos se deve a estes materiais ut...

Страница 11: ...CALL POINT BExCP3B C D PB PUSH BUTTON MANUAL CALL POINT BExCP3B C D PT TOOL RESET MANUAL CALL POINT IS CP4B BG BREAK GLASS MANUAL CALL POINT IS CP4B PB PUSH BUTTON MANUAL CALL POINT IS CP4B PT TOOL R...

Страница 12: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment BExCP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db...

Страница 13: ...y high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11...

Страница 14: ...CP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db eb IIC T6 Gb 40 C Ta 70 C II 2D Ex tb IIIC T75 C Db 40 C Ta 70 C or II 2G Ex db eb mb IIC T4 Gb 40 C Ta 50 C II 2D Ex tb IIIC T60 C Db 40 C Ta 50 C or...

Страница 15: ...d by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11 2001 clause 4 7 BExCP3A BG B BG C BG D BG only fitted with burning house symbol shown in figure 3...

Отзывы: