background image

 

 

European Safety Systems Ltd.

  Impress House, Mansell Road, Acton, London W3 7QH 

 

 

 

 

 

[email protected]  Tel: +44 (0)208 743 8880 

Document D150-00-055-IS   Issue 1   26-08-20 

 

 

Sheet 3 of 3 

 

 

 

www.e2s.com  Fax +44 (0)208 740 4200 

 

 

 
Pivot point     Test Cam    Top Cam (rotate) 
 
Replace  the  cover  plate  and  tighten  the  4  off  M4 
cap head screws. 
 
Ensure the glass element is free to move under the 
cover  plate.  This  can  be  done  by  running  through 
the  units  test  operation.  See  section  8  of  this 
instruction manual. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10)  SIL 2 Reliability Data 

Reliability  and  Functional  safety  IEC/EN61508 
which  has  been  assessed  and  is  considered 
suitable for use in low demand safety function:  
  
•  Random Hardware Failures and Systematic 
   Failures (route 2H) 
•  As an unvoted item (i.e. hardware fault tolerance 
    of 0) at SIL 2 
The product was assessed against failure modes: 
 
•  Failure to close a contact when the call point is 
   struck with specified force 
•  Failure to open a contact when the call point is 
   struck with specified force 
•  Spurious output despite no input 

 
 

Integrity in respect of failure to close

SIL 2

Total Failure rate 

0.133 pmh 

“hazardous” failure rate (revealed) 

0 pmh 

“hazardous” failure rate (unrevealed)

0.1 pmh

“safe” failure rate (revealed)

0.033 pmh

“safe” failure rate (unrevealed) 

Diagnostic Coverage

99%

System type

A

Hardware Fault Tolerance

0

Safe Failure Fraction

>99%

PFD (hazardous failure)

1.25 x 10

‐3

Proof Test Interval

Up to 1 year