background image

 

 

E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH    [email protected]        e2s.com                                            D221

-

00

-

201

-

IS Issue 3  30/06/2022 

 

 

AL112NXDC024 / AL112NXDC048  (P2) @ 1m

 

 

Horizontal Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Horizontal Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

106.1

 

105.8

 

105.1

 

105.4

 

105.2

 

93.9

 

101.2

 

101.6

 

101.1

 

101

 

101.2

 

91

 

45°

 

105.2

 

107.2

 

106.3

 

104.1

 

98.7

 

101.6

 

101.3

 

102.9

 

102.1

 

100.2

 

94.7

 

99

 

75°

 

112.1

 

112.6

 

111.9

 

111.7

 

110.1

 

104.8

 

108.1

 

108.5

 

107.7

 

108.1

 

106.5

 

103

 

105°

 

111.9

 

112.5

 

111.7

 

111.7

 

110.2

 

104.8

 

107.9

 

108.4

 

107.6

 

108.1

 

106.4

 

103

 

135°

 

104.8

 

107.4

 

106.4

 

103.8

 

99.2

 

101.6

 

101.1

 

103.2

 

102.1

 

99.8

 

95.5

 

99

 

165°

 

105.2

 

105.8

 

105.2

 

105.3

 

105.1

 

93.8

 

100.8

 

101.5

 

100.8

 

100.9

 

102

 

90.8

 

 

Vertical Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Vertical Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

107.2

 

107.1

 

105.9

 

107.4

 

105.5

 

95.5

 

103.1

 

102.8

 

101.5

 

103.1

 

101.5

 

91.8

 

45°

 

106

 

109.3

 

107.9

 

104.6

 

100.5

 

103.7

 

102.2

 

105.4

 

103.8

 

100.4

 

96.6

 

99.9

 

75°

 

113.2

 

113.3

 

112.9

 

113

 

110.8

 

106.1

 

109.2

 

109.3

 

108.7

 

109.1

 

107.1

 

103

 

105°

 

112.9

 

113.1

 

112.7

 

112.8

 

111.4

 

106.1

 

109

 

108.9

 

108.5

 

108.9

 

107.7

 

103.1

 

135°

 

105.5

 

109.3

 

107.7

 

104.7

 

100.3

 

104.3

 

101.4

 

105.3

 

103.5

 

100.7

 

96.5

 

100.7

 

165°

 

107

 

106.5

 

105.9

 

106.4

 

105.3

 

95

 

102.6

 

102.1

 

101.5

 

102.2

 

101.1

 

91.2

 

AL112NXDC024 (P1) @ 1m

 

 

Horizontal Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Horizontal Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

103.3

 

103.7

 

103.1

 

103.3

 

103.2

 

91.5

 

101

 

101.5

 

100.9

 

101

 

100.3

 

89.4

 

45°

 

103.4

 

104.8

 

104.2

 

101.6

 

96.3

 

99.4

 

101.5

 

102.7

 

101.8

 

99.6

 

94.3

 

97.4

 

75°

 

109.1

 

110.4

 

109.7

 

109.6

 

108.3

 

103.2

 

107.1

 

108.2

 

107.4

 

107.7

 

105.9

 

101.4

 

105°

 

109.9

 

110.2

 

109.6

 

109.7

 

108.6

 

103

 

107.7

 

108.1

 

107.4

 

107.6

 

105.9

 

101.6

 

135°

 

103.4

 

104.8

 

104

 

101.8

 

96.5

 

99.4

 

101.1

 

102.8

 

101.7

 

99.6

 

94.5

 

97.4

 

165°

 

103.4

 

103.5

 

103

 

103.3

 

103

 

91.6

 

101

 

101.4

 

100.8

 

101.1

 

100.2

 

89.4

 

 

Vertical Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Vertical Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

104.1

 

104.1

 

103.2

 

104.1

 

102.3

 

92.3

 

101.8

 

101.8

 

100.8

 

101.8

 

100

 

90.4

 

45°

 

103.4

 

106.4

 

105.2

 

101.9

 

96.3

 

100.2

 

101.3

 

104.3

 

103.1

 

99.7

 

94.1

 

98.2

 

75°

 

109.8

 

110.1

 

109.8

 

110.4

 

108.3

 

103.2

 

107.7

 

107.8

 

107.7

 

108.4

 

106.2

 

101.4

 

105°

 

109.1

 

109.9

 

109.5

 

110

 

108.3

 

102.9

 

106.9

 

107.7

 

107.1

 

107.6

 

105.7

 

101.3

 

135°

 

101.1

 

106.4

 

104.7

 

101.8

 

96.6

 

101

 

100.6

 

104.1

 

102.3

 

99.6

 

94.5

 

99.1

 

165°

 

103.6

 

103.1

 

102.8

 

103.6

 

102.8

 

91.8

 

101.2

 

100.9

 

100.7

 

101.4

 

99.8

 

89.8

 

Order Code: AL112NXDC024

 

Voltage Range: 20

-

28Vdc

 

Nominal Voltage: 24Vdc 

 

Max Sounder Current: P1: 280mA @ 

20Vdc; P2: 430mA @24Vdc 

 

Max Beacon Current: 271mA @ 20Vdc

 

DP

-

2821

-

CPR

-

0110

 

Construction Product Regulation

 

• 

AL112NXDC024 & AL112NXDC048 are compliant to EN54

-

3:2001+A1+A2 & EN54

-

23:2010

 

• 

VAD for use in fire detection and fire alarm systems installed in and around buildings 

 

• 

Type 4 / 4X / 3R / 13, IP66, Independently tested to EN60529:1991, (IP33C Compliant to 
EN54

-

3)

 

• 

Type B Product, For Indoor & Outdoor use

 

• 

Observe Precautions for handling electrostatic devices

 

• 

-

25°C to +55°C compliant to EN54

-

3

 

• 

Cable Glands must be suitably sealed and meet minimum IP33 for EN54

-

3 applications

 

• 

Storage Temperature: 

-

40°C to +70°C

 

• 

Maintenance –

 

None

 

• 

Mounting 

-

 Units can be mounted using the 2

-

off ø9mm holes in the mounting lugs or 

through the back of the housing using the supplied gasket seal.

 

 

Approved Tones for EN54

-

3 Applications:

 

 

•(

Alternating Tone) 800/1000Hz @ 2Hz Alternating Tone 44

 

•(

Rising Tone) 500/1200Hz @ 0.26Hz (3.3s on, 0.5s off) Tone 8

 

•(

Fainting Tone) 1200/500Hz @ 1Hz Tone 2

 

•(

Continuous Tone) 800Hz Tone 21

 

•(

Pulsed Tone) 660Hz (150mS on, 150mS off) Tone 31

 

•(

Alternating Tone) 544Hz(100mS)/440Hz (400mS) Tone 5

 

2821

 

S36282

 

21

 

2821

 

S36282

 

21

 

Order Code: AL112NXDC048

 

Voltage Range: 42

-

52Vdc

 

Nominal Voltage: 48Vdc 

 

Max Sounder Current: P1: 280mA @42Vdc;

 

 

P2: 430mA @42Vdc 

 

Max Beacon Current: 160mA @ 42Vdc

 

DP

-

2821

-

CPR

-

0110

 

Содержание AlertAlight AL112NXDC012

Страница 1: ...iker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden Attenzione L installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti Atención La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones Atenção A instalação deve ser realizada por um eletricista de acordo com os códigos e regula...

Страница 2: ...0 201 IS Issue 3 30 06 2022 See D221 06 205 S2 S3 S2 S1 DC A B C S2 S1 L N L N E C S2 S3 E N L AC E N L See D221 06 201 P1 P2 Default S2 Tone 1 Default S1 Tone 44 ON 1 OFF 0 AC DC See D221 95 001 A B C A B C A B C A B C A B C DC Only DC Only Not CPR Compliant Not CPR Compliant 1Hz 1 5Hz 2x P1 P2 ...

Страница 3: ...AL AL112NX AlertAlight Combined Sounder Xenon E2S Warning Signals Impress House Mansell Road Acton London W3 7QH sales e2s com e2s com D221 00 201 IS Issue 3 30 06 2022 6x 1Nm ø20mm 190 7 48in 35 9 1 41in 35 9 1 41in 61 2 40in ...

Страница 4: ...7 6 105 9 101 6 135 103 4 104 8 104 101 8 96 5 99 4 101 1 102 8 101 7 99 6 94 5 97 4 165 103 4 103 5 103 103 3 103 91 6 101 101 4 100 8 101 1 100 2 89 4 Vertical Sound Output Max Voltage 54 Vdc LAFmax T dB A Vertical Sound Output Min Voltage 11 5 Vdc LAFmax T dB A Angle Tone 44 Tone 8 Tone 2 Tone 21 Tone 31 Tone 5 Tone 44 Tone 8 Tone 2 Tone 21 Tone 31 Tone 5 15 104 1 104 1 103 2 104 1 102 3 92 3 1...

Страница 5: ...ength of the sides of the square mounting height from the floor and y is the Wall mounted where x is the maximum Category W x y Wall mounted V 55 3m V 62 5m 11W Power 14W AL112NXDC024 AL112NXDC048 LIGHT OUTPUT Note CPR aproved units must be positioned sounder on top beacon below table are VdS Approved Only units in the following Coverage Area According to EN54 23 AL112NXDC024 AL112NXDC048 Category...

Страница 6: ...o limitations on orientation Factory finishes are not intended to be modified Attention Installation must be carried out by an electrician in compliance with the National Electrical Code NFPA 70 and the National Fire Alarm Signaling Code NFPA 72 or CSA 22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations Section 32 L installation doit exclusivement être réalisée par du...

Страница 7: ... 129 3 dB A 49 3 dB A 126 3 dB A 49 3 dB A 131 6 dB A 39 6 dB A 140 6 dB A 40 6 dB A 180 92 6 dB A 0 91 2 dB A 180 92 5 dB A 0 90 8 dB A S2 S3 S2 S1 AL112NXDC024 Sounder PCBA P1 P2 100 0 L 10 14 VDC AC 20 28 VDC AC 42 54 VDC AC 48 VAC pos neg N E L L N E L N A B C AL112NXDC024 Beacon PCBA A B C A B C A B C A B C 1Hz Flash 60FPM 1 5Hz Flash 90FPM Double Strike Flash Pattern Header Pin Settings for ...

Страница 8: ...tage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve WIRING LINKING BEACON SOUNDER FACTORY FITTED 6 R1 R1 S2 S3 R1 S2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage...

Страница 9: ...FITTED D221 06 201 AL112NX AL121X DC COMBINED SOUNDER XENON WIRING DIAGRAMS 6 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 2 Common Positive Customer Set H1 H2 to ...

Страница 10: ...IONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF 3 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D221 06 201 AL112NX AL121X DC COMBINED SOUNDER XENON WIRING DIAGRAMS 6 WIRING LINKING BEACON SOUNDER FACTORY FITTED OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN...

Страница 11: ...Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve ve IN ve IN D221 06 201 AL112NX AL121X DC COMBINED SOUNDER XENON WIRING DIAGRAMS 6 4 R2 ve OUT ve OUT R1 R1 S2 R1 S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Singl...

Страница 12: ...COMBINED SOUNDER XENON WIRING DIAGRAMS 6 5 S2 S3 R1 S2 R2 R1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 6 Common Positive Customer Set H1 H2 to Negative Switching See Below Sta...

Страница 13: ...IONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D221 06 201 AL112NX AL121X DC COMBINED SOUNDER XENON WIRING DIAGRAMS 6 6 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MIN...

Страница 14: ...L SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D221 06 205 R S RAIT B ISARD R N POTTS OF AL112NX AL121X COMBINED SOUNDER XENON WIRING DIAGRAMS NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Earth Earth Stage 2 Stage 3 Common L N L N N N L L E N N L L E C S2...

Страница 15: ...O NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D221 06 205 R S RAIT B ISARD R N POTTS OF AL112NX AL121X COMBINED SOUNDER XENON WIRING DIAGRAMS NTS 2 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 2 Stage 1 Live IN Stage 1 Live OUT Stage 1 Neutral IN Stage 1 Neutral OUT Earth Live IN Live OUT Neutral IN Neutral OUT Earth Stage 2 Stage 3 Common N N L...

Страница 16: ... 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 0...

Отзывы: