OPERATOR’S MANUAL
with Maintenance Information
Function Tests
46
62 Try to raise the platform.
⊙
Result: The platform can be raised the
alarm should beep 50 times per minute and
continue, the platform LED display shows
"0b". (Obstacle)
63 Press the drive function enable button to
drive the machine to a stop at 2 meters
away from the obstacle. Rotate the
platform controller until the directly above
of the ultrasonic sensor in line with the
obstacle.
64 Press the lift function enable button, press
and hold the function enable button on the
joystick, and slowly approach the obstacle.
⊙
Result: When the platform control is 2m
away from the obstacle, the alarm will beep
110 times per minute, and the platform
LED display shows "0b".(Obstacle)
¤
Result: When the platform control is 2m
away from the obstacle, the anti-collision
warning alarm will not sound (beep). Mark
the machine immediately. And stop
function.
65 Raise the platform while ensuring that the
ultrasonic sensor moves in line with the
obstacle.
⊙
Result: When the platform control is 1.5m
away from the obstacle, the platform will
stop the lift function, the alarm should
continue to beep 110 times per minute, and
the platform LED display shows "0b".
(Obstacle)
¤
Result: When the platform control is 1.5m
away from the obstacle, the anti-collision
warning alarm (beep) does not sound, and
the platform will continue to rise. Please
mark the machine immediately. And stop
function.
66 Release the joystick and raise the machine
again within 5 seconds (within the time the
alarm sounds).
⊙
Result: The platform will continue to raise,
the alarm should continue to beeps 110
times per minute, and the platform LED
display shows "0b".(Obstacle)
67 Release the joystick and raise the machine
again after 5 seconds (after the alarm
stops).
⊙
Result: The lift function will be disabled and
not allowed to raise, the alarm should
sound continuously 110 beeps per minute,
and the platform LED display shows
"0b".(Obstacle)
Note: The ultrasonic safety sensor will only
protect the operator and platform directly
above the platform control.
Содержание S06-ACE
Страница 3: ......
Страница 5: ......
Страница 18: ...OPERATOR S MANUAL with Maintenance Information Decals 13 S06 HAE ACE...
Страница 22: ...OPERATOR S MANUAL with Maintenance Information Decals 17 S0608 HAE ACE S1412 HAE ACE...
Страница 23: ...OPERATOR S MANUAL with Maintenance Information Decals 18...
Страница 110: ...OPERATOR S MANUAL with Maintenance Information Schematic 105 Inspection and Repair Log Date Comments...