1
PDF1 Barcode
If there is a problem in reading a PDF417 on the card, the reader reports an error using the ASCII string “
NR
”
(HEX 45 & 52) followed by a character
indicating a type of error. The error types are:
“
0
” : Not found a PDF417 symbol
“
1
” : Too many damaged code-words
“
” : Too many Misread code-words
“
3
” : Codeword translation to ASCII error
Any enabled prefixes or suffixes are appended around this message. The reader does not send the Code ID
even in case that the option is enabled.
Scanner Response
ACK / NAK
Description
Field
Values allowed
No-Read Message
Enable
NOREAD=1
Disable *
NOREAD=0
Working With Engine
Registration Key Read & Write
Description:
To setup Registration Key, changes will be effective after scanner ACK response. Control char-
acters are not permitted. The maximum length is 30 characters*. When the REGIEN option is enabled, the
data will be added between serial number and decoded data.
Example:
‘SOH’<REGKEY:>‘EOT’
Scanner Response:
ACK “XXXXXXXXXX…\r\n” / NAK
X is a printable ASCII, with variable length
Scanner Response:
ACK / NAK
Description
Field
Values allowed
Reg. Key Read
REGKEY:
Add to stream
Enable
REGIEN=1
Disable *
REGIEN=0
Reg. Key Write
REGKEY=