E-Plex 413DWM Скачать руководство пользователя страница 6

52 – 54 Riverside, Sir Thomas Longley Road, Medway City Estate, Rochester, Kent ME2 4DP

tel: +44 (0)1634 711622  fax: +44 (0)1634 290773

email: [email protected]
web: www.e-plex.co

Important Notice: E-Plex Ltd. (E-Plex) reserves the right to make changes to or discontinue any product or service identified in this publication without notice. E-Plex advises its customers to obtain 
the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current. E-Plex assumes no responsibility for infringement of patents or 
rights of others based on E-Plex applications assistance or product specifications since E-Plex does not possess full access concerning the use or application of customers’ products. E-Plex also 
assumes no responsibility for customers’ product designs.

Powering Systems - Empowering Designers

Содержание 413DWM

Страница 1: ...ion Local electronic override capabilities Designed for motor loads LEN value 2 Introduction The E Plex 413DWM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total The six channels can be utilized as either inputs outputs or a combination of both The individual channels may be combined in order to handle larger amperage loads With four diode...

Страница 2: ... Measured at 10 A load 6 PWM not recommended for motor loads unless factory authorized 7 For load resistance greater than 2 ohms load inductance is unlimited 8 Specified as 50 feet of 2 AWG 43 mm wires with a 6 inch diameter spool for both power and ground 9 For a channel configured as an input this specifies the turn on off threshold impedance 50K Description Minimum Nominal Maximum Absolute Maxi...

Страница 3: ...0A 7 32VDC Status LEDs ON Channels 1 6 indicates Load ON E Plex channel indicates module responding OFF Channels 1 6 indicates Load OFF E Plex channel indicates module not responding 10 BLINKING Channels 1 6 indicates Load FAULT E Plex channel indicates module responding Power Battery Connections Must be fused at a maximum of 50A Maximum wire size should be sized based on upstream fuse When connec...

Страница 4: ...o protect channel from back feeding from an external source Cable Range AWG mm2 Female Terminal Terminal Insulation Range Seal Insulation Range Seal P N 18 16 1 0 0 75 mm2 15304716 1 70 2 25 mm 1 20 1 85 mm 15366063 1 85 2 25 mm 15356064 16 12 2 50 1 50 mm2 15304717 2 20 3 00 mm 2 09 2 66 mm 15366061 2 70 3 2 mm 15336674 Status LEDs Channels 1 6 and E Plex10 Ch 6 Ch 5 Ch 4 Ch 3 Ch 2 Ch 1 E Plex Ch...

Страница 5: ...cted EP SW IO 6CH 413DWM Connectors J1 Brown Mates to Delphi P N 15317308 J2 Blue Mates to Delphi P N 15317304 Cavity Plug Delphi P N 12059168 Power Stud Connections M5 nickel plated brass 127mm 5 00 63 5mm 2 50 113 3mm 4 46 13 7mm 0 54 73 7mm 2 90 92 7mm 3 65 135 6mm 5 34 45 7mm 1 80 Ø0 39 Ø9 91 Ø 6 10mm 0 24 x 2 Ø 5 08mm 0 20 12 9mm 0 51 11 9mm 0 47 8 1mm 0 32 4 8mm 0 19 63 5mm 1 50 ...

Страница 6: ...E Plex advises its customers to obtain the latest version of the relevant information to verify before placing any orders that the information being relied upon is current E Plex assumes no responsibility for infringement of patents or rights of others based on E Plex applications assistance or product specifications since E Plex does not possess full access concerning the use or application of cu...