Operation

:

5-1 Insulation

 

testing

:

Maintenance:

5

6

Digital

 

 intelligent

 

 insulation  meter

3

4

1. Outer DC power socket.

2. Gear selected key-press.

3. Measuring range key-press.

4. Hand-strap position.

5. Power key-press.

6. Test key-press, spin to lock.

7. Display screen.

8. Measurand ground terminal connected socket.

9. Voltage input terminal.

10.Ground terminal, connecting to protect the ring 
electrode when testing for the cable.

11. Tested terminal socket.

Turn on the instrument by pressing the power key-press. Please 
replace the batteries timely when the low power symbol displayed.

1

.

 Connect

 

the

 

measurand

 

ground

 

terminal with the input wire 

E, and connect the tested terminal to L.(Make the L terminal 
connection hand in the air as much as possible. Please 
connect to the COM terminal when testing for the cable.)

2. According to the detecting mission, select the proper gear, then 
LCD will display the corresponding voltage; if the tested voltage is 
unclear, try from the low gear, when it show as”1", change to the 
higher gear to continue.
3. Select the proper measuring range, press the 

TEST 

key, then 

the 

and 

E

  terminal will have high voltage output, LCD display 

symbol  , the high voltage indicate light will light up.
4. Press down the 

TEST 

key to progress the measuring, readout 

the value when it display stable. Release the 

TEST 

key when 

finished, the LCD will display “1".
(If the TEST press-key down but the LCD still display “1", it’s 
possibly cause by: 
A: The tested resistance has over the selected range or over the 
Max. measuring range.
B: The wire maybe not being well connected or disconnected.

5. Press the TEST key and spin clockwise to lock and 
measuring continuously.
6.Caution: It’s prohibit from pushing/pulling the connecting 
wire or touching the tested resistance when the TEST key is 
being press down cause the L  and E terminals will have high 
voltage output.
If the readout bing unstable all the time, it’s possible because:
A: The connecting wire is too long.
B: The humidity of the testing environment may be a little high.
C: The outer layer of the tested resistance need to be 
connected to the COM.
D: The tested resistance is unstable, lies in critical state.
7.  When progressing the insulation test, please use the 
conductor to protect around the measurand’s appearance 
between the two tested terminals in order to eliminate the 
measuring inaccuracy which generated from the current’s 
leakage of the measurand’s appearance. Plus, the protected 
conductor should be connected to the COM terminal with the 
wire.

5-2 AC Voltage measuring

1. Press the 

gear

 

of 

750V~, 

connect the 

ACV

 terminal with 

the red test pen, and the 

COM

 terminal with the black one.

2. Full contact two tested terminals and parallel  to the 
electric power with the testing probe. The readout on the 
LCD screen is the measuring result
3. If the LCD displayed as “000", it indicates that the tested 
voltage is zero or the connected wire may be 
disconnected.

1. This instrument is a precision measuring instrument, please 

avoid using under bad environment, it's not allow to change the 
circuit, replace the component and calibrate and repair the meter 
without obtaining the authorization of the Product Service Center 
of our company.

2.If there is no display on the LCD even when there is power 

left, then please check the connecting condition of the batteries.

3.The batteries should be replaced when the low power symbol 

displayed. Make sure the measuring circuit is cut off. Loose the 
screw of the battery box, take out the batteries and install the new 
one, please pay attention to the polarity, after that, put back the 
cover and fasten with screw.

4.If you don't use the meter for a long period, please take out 

the batteries to prevent the electrolyte leakage which may affect 
the usage of the meter or even damage the meter.

Please  full  read  this  user  manual  carefully  before  using.  If  you 
have  any  further  question  during  your  usage,  please  feel  free  to 
contact us.
Tel: 0756-8659101
Skype

e

-

one

.

caroline

QQ/Wechat: 373234353
Website: http://e.e-one.net.cn/

Further service:

Digital

 

 intelligent

 

 insulation  meter

Отзывы: