Master/Global
71
1. Recalibrate
With this function you can set minimum and maximum values for the
volume control. If you feel that the volume control is not working
correctly, it may be time to recalibrate.
1. Activate Master/Global module.
2. Select 8. Special, 1. Volume Recalibrate (8/1).
3. Move the volume control to the minimum position, then press
ENTER.
VOLUME RECALIBRATE
Min: - 12245
Set Minimum Volume
4. Move the volume control to the maximum position, then press
ENTER again.
VOLUME RECALIBRATE
Min: - 12245
Max: + 13352
Set Maximum Value
5. Check the movement of the control.
Verify that the volume control
operates properly.
Press ENTER.
6. To save the calibration, press Yes.
To cancel the calibration, press
No. In either case, the ESI-32 will return to the Module Identifier.
2. Contrast
This function allows you to change the viewing angle of the LCD so that
it may be easily read from either above or below. The angle is adjustable
from +7 to -8. Positive values make the display easier to rea from above.
Negative values make the display easier to read from below.
1. Activate Master/Global module.
2. Select 8. Special, 2. Contrast (8/2)
3. Select the desired contrast setting.
CONTRAST
Contrast: -2
Select Contrast
4. Press ENTER to exit the submodule.
The ESI-32 will return to the
Module Identifier.
Содержание ESI-32
Страница 4: ...iv ESI 32 Operation Manual ...
Страница 10: ...2 ESI 32 Operation Manual ...
Страница 26: ...18 ESI 32 Operation Manual ...
Страница 28: ...20 ESI 32 Operation Manual ...
Страница 36: ...28 ESI 32 Operation Manual ...
Страница 64: ...56 ESI 32 Operation Manual ...
Страница 100: ...92 ESI 32 Operation Manual ...
Страница 102: ...94 ESI 32 Operation Manual ...
Страница 114: ...106 ESI 32 Operation Manual ...
Страница 166: ...158 ESI 32 Operation Manual ...
Страница 188: ...180 ESI 32 Operation Manual ...
Страница 206: ...198 ESI 32 Operation Manual ...
Страница 208: ...200 ESI 32 Operation Manual ...